Loading...
HomeMy WebLinkAboutGN101 - OA101 - Code Plan & Contractor NotesACCORDING TO THE PROJECT MANUAL, SECTION 013300 - SUBMITTALS: · ALL SUBMITTALS REQUIRED IN PROJECT MANUAL SECTIONS SHALL BE SUBMITTED TO THE GENERAL CONTRACTOR FOR REVIEW. · AFTER THE GENERAL CONTRACTOR'S REVIEW, THE SUBMITTALS LISTED BELOW SHALL BE TRANSMITTED TO THE ARCHITECT FOR REVIEW. IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO TRANSMIT THE SUBMITTALS LISTED BELOW. NEITHER THE ARCHITECT NOR THE ENGINEER IS RESPONSIBLE FOR REVIEW OF THESE ITEMS IF NOT RECEIVED. DESIGN PROFESSIONAL REVIEW OF SUBMITTALS ANY COMPONENT OF DELEGATED DESIGN 033000CAST-IN-PLACE CONCRETE 051200STEEL CONSTRUCTIONS 053100STEEL DECKING 061753FABRICATED WOOD TRUSSES 075419PVC ROOFING SYSTEM 076113METAL ROOFING 220000PLUMBING 230000HEATING, VENTILATING AND AIR CONDITIONING TEST AND BALANCE REPORT 265000ELECTRICAL EQUIPMENT & INSTALLATION PLUMBING FIXTURE REQUIREMENTS WC - F WC - M WC-UNISEX URINAL LAV - F LAV-M LAV - UNISEX SERV. SINK DF REQUIRED:2 2 -0 1 1 - 1 0 PROVIDED:2 1*1 1*1 1 1 1 0** *PER FOOTNOTE I, 1 URINAL MAY BE SUBSTITUTED FOR 1 WATER CLOSET **PER FOOTNOTE H, WATER WILL BE SERVED FREE OF CHARGE OCCUPANT LOAD = 202 TOTAL FEMALES = 101 MALES = 101 CODE REVIEW BASED ON CHAPTER 29 OF THE 2014 INDIANA BUILDING CODE 67" Ø CLEA R 30"x52" CLEARFEC-1FE-2 30"x52" CLEAR FE-1 48" x 60" MINENTRY PATIO EXIT EXIT EXIT EXIT $$$$$$$$2,013 SF / 200 SF GROSS = 11 OCC 408 SF/ 5 SF NET= 82 OCC 70 SF/ 100 SF NET=1 30"x52" CLEAR ENTRY DRIVE-THRU SERVICE SUNDAE SERVICE MOP ROOM OFFICE UTILITY ROOM DRY GOODSDISHWASHING WOMEN COOLER FREEZER CUSTOMER SERVICE ENTRY TOILET HALL CUSTOMER ORDER AREA DINING DRINKS & CONDIMENTS KITCHEN PREP AREA MEN DUMPSTER ENCLOSURE SHED 711 SF / 15 SF NET = 48 OCC TRAVEL DISTANCE = 88' ·NOT ALL ITEMS ARE PROVIDED AND INSTALLED BY GC. ·SEE FOOD SERVICE PLAN FS-1 FOR RESPONSIBILITIES OF FOOD SERVICE EQUIPMENT AND RELATED ITEMS. ·SEE TOILET ROOM ACCESSORIES SCHEDULE FOR RELATED RESPONSIBILITIES. ·RESPONSIBILITIES FOR OTHER ITEMS AS LISTED BELOW. ·ANY ITEMS NOT INCLUDED BELOW OR ABOVE ARE ASSUMED TO BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. IT SHALL BE THE GC'S RESPONSIBILITY TO CONFIRM OR SEEK CLARIFICATION IF DISCREPANCIES ARE FOUND. OWNER FURNISHED, VENDOR INSTALLED - PARTIAL GC RESPONSIBILITY OWNER FURNISHED, CONTRACTOR INSTALLED ITEM NOTES PATIO TABLES AND CHAIRS DRIVE THRU SENSOR LOOP SEE SITE ELECTRICAL DETAILS ARTWORK / DECOR SEE DECOR PLAN OFFICE CASEWORK & FURNISHINGS CONFIRM SELECTIONS WITH OWNER; SEE ALSO FLOOR PLAN. COORDINATE. DIGITAL FEATURE BOARD(S), BRACKETSSEE ALSO POWER AND COMMUNICATIONS PLAN CUSTARD CONDENSING UNITS SEE ROOF PLAN & ROOF ELECTRICAL PLAN WALK-IN CONDENSING UNITS (PROVIDED BY FSEC) SEE ROOF PLAN & ROOF ELECTRICAL PLAN RESPONSIBILITIES INFORMATION ITEM NOTES PATIO UMBRELLAS OPTIONAL - MAY NOT BE INCLUDED PYLON / MONUMENT SIGN(S)SEE SITE ELECTRICAL AND SITE SIGNAGE SCHEDULE FOR GC SCOPE AND COORDINATION NOTES. SITE DIRECTIONAL SIGNS SEE SITE ELECTRICAL AND SITE SIGNAGE SCHEDULE FOR GC SCOPE AND COORDINATION NOTES. DRIVE THRU MENU BOARD SEE SITE ELECTRICAL AND SITE SIGNAGE SCHEDULE & POWER AND COMMUNICATIONS PLAN FOR GC SCOPE AND COORDINATION NOTES. ORDER CONFIRMATION BOARD (OCB) GC SHALL PROVIDE CONCRETE FOUNDATION PER S101 IF OCB DOES NOT INCLUDE CANOPY; CONFIRM WITH OWNER. SEE SITE ELECTRICAL PLANS AND DETAILS AND POWER AND COMMUNICATIONS PLAN FOR GC SCOPE AND COORDINATION ITEMS. BUILDING-MOUNT SIGNAGE SEE ALSO BUILDING ELEVATIONS AND ROOF ELECTRICAL PLAN. LED STRIP LIGHT AT TOP OF PARAPET OPTIONAL, MAY NOT BE INCLUDED. SEE ALSO BUILDING ELEVATIONS AND WALL SECTIONS. SEE LIGHTING PLAN FOR GC SCOPE AND COORDINATION ITEMS. AWNINGS GC SHALL COORDINATE AND PROVIDE BLOCKING; SEE ALSO BUILDING ELEVATIONS AND WALL SECTIONS. POINT OF SALE (POS) SYSTEM GC TO SET BOXES AND PULL SIRES. SEE ALSO POS SYSTEMS PLAN AND ELEVATIONS. HEADSETS, SURVEILLANCE / SECURITY SYSTEM, MUSIC, PHONE / INTERNET GC TO COORDINATE. SEE ALSO POWER & COMMUNICATIONS PLAN FOR ITEMS OF GC SCOPE. SODA SYSTEM GC TO COORDINATE. SEE ALSO FOOD SERVICE PLAN, PLUMBING FOOD SERVICE ROUGH-IN PLAN & SCHEDULE, AND KITCHEN POWER PLAN. Co2 SYSTEM GC TO COORDINATE WITH VENDOR HVAC TEST AND BALANCE GC TO COORDINATE WITH VENDOR 1.CULVER FRANCHISING SYSTEM, LLC = "CFS" 2.GENERAL CONTRACTOR (GC) TO CONTACT CFS PROJECT COORDINATOR TO SET UP CONSTRUCTION COORDINATION PHONE CALL PRIOR TO GROUND BREAK OF PROJECT. 3. GC SHALL PROVIDE CFS WITH A PROJECT SCHEDULE PRIOR TO CONSTRUCTION. 4. GC TO SEND WEEKLY OR BIWEEKLY NOTES AND PHOTOS TO PROJECT COORDINATOR AS AGREED UPON AT START OF PROJECT. 5. EXPECT A MINIMUM 8-10 WEEK LEAD TIME FOR ALL FINISHES AND MEP EQUIPMENT. CONTACT CFS FOR CURRENT LEADTIME EXPECTATIONS TO CONFIRM. CONTRACTORS SHALL USE NATIONAL ACCOUNTS AS LISTED BELOW FOR CULVER'S PRICING: INTERIOR FINISHES - SEE FINISH PLAN FOR CONTACTS AND INFO CARPET FLOOR TILE & WALL TILE WAINSCOTING FRP INTERIOR LAMINATE DOORS & HARDWARE VINYL WALLCOVERING BACK OF HOUSE FLOORING EXTERIOR FINISHES - SEE BUILDING ELEVATIONS FOR CONTACTS AND INFO MANUFACTURED STONE VENEER BOLLARD COVERS DRIVE THROUGH SERVICE WINDOW - SEE WINDOW SCHEDULE FOR CONTACTS AND INFO ROOFING - SEE ROOF PLAN FOR CONTACTS AND INFO PLUMBING FIXTURES AND WATER HEATER - SEE PLUMBING SCHEDULE SHEET FOR CONTACTS AND INFO ELECTRICAL FIXTURES, GEAR, AND DEVICES - SEE SITE LIGHTING DETAILS AND LIGHTING PLAN FOR CONTACTS AND INFO MECHANICAL - SEE HVAC SCHEDULES AND DETAILS FOR CONTACTS AND INFO RTUs EXHAUST HOODS & FANS ANSUL SYSTEM CEILING DIFFUSERS TEST AND BALANCE REPORT (TAB) GENERAL NOTES FOR GC REGARDING CONSTRUCTION CODE REVIEW TABLE ENERGY CODE DATA CLIMATE ZONE 5A IECC C301.1 LIFE SAFETY DATA REFERENCE BUILDING USE GROUP A-2 IBC SEC. 303.1 CONSTRUCTION TYPE 5B (Combust.-Unprotected)IBC SEC. 602.5 BUILDING HEIGHT IBC TBL. 503 ALLOWABLE EAVE HEIGHT 1 STORY, 40' PROPOSED EAVE HEIGHT1 STORY, +/-23'-3" BUILDING AREA IBC tbl. 503 ALLOWABLE AREA 6,000 SF INCREASE - FRONTAGE, 100% OPEN PERIMETER 4,500 SF IBC 506.2 INCREASE - SPRINKLER SYSTEM 18,000 SF IBC 506.3 TOTAL ALLOWABLE AREA28,500 SF TOTAL PROPOSED AREA (FIRE AREA)5,135 SF ROOF PRINT FIRE SUPPRESSION BLDG is FULLY SPRINKLERED REQUIRED PROTECTION OF BUILDING ELEMENTS IBC TBL. 601 STRUCTURAL FRAME 0 HR BEARING WALLS 0 HR NONBEARING WALLS AND PARTITIONS-INTERIOR0 HR FLOOR CONSTRUCTION 0 HR ROOF CONSTRUCTION 0 HR EXTERIOR WALL FIRE RESISTANCE RATING IBC TBL. 602 FIRE SEPARATION DISTANCE > 30'0 HR CONCEALED SPACES with SPRINKLERS IBC 717.4.3 ATTIC DRAFTSTOPPING NOT REQUIRED INTERIOR FINISH REQUIREMENTS with SPRINKLERS IBC TBL. 803.9 EXIT ENCLOSURES AND EXIT PASSAGEWAYS B CORRIDORS B ROOMS & ENCLOSED SPACESC FIRE PROTECTION SYSTEM REQUIRED IBC 903.2.1.2 FIRE AREA > 5,000 SF FIRE AREA OCCUPANT LOAD > 100 FIRE AREA AT LEVEL OF EXIT DISCHARGE MANUAL FIRE ALARM AND DETECTION SYSTEMS 1 BOX REQUIRED IBC sec. 907.2 Occupant Load < 300 ADDITIONAL NOT REQUIRED IBC sec. 907.2.1 MEANS OF EGRESS OCCUPANT LOAD 97.6 LF Fixed Booth Seating @ 24" / occ 49 occ., 41 occ. ACTUAL IBC 1004.7 711 SF Unconcentrated table/chairs @ 15 SF net/occupant48 occ., 59 occ. ACTUAL IBC tbl. 1004.1.2 408 SF Standing Space @ 5 SF net/occupant82 occ. IBC tbl. 1004.1.2 70 SF Business @ 100 SF gross/occupant1 occ. IBC tbl. 1004.1.2 2,013 SF Commercial Kitchen @ 200 SF gross/occupant11 occ. IBC tbl. 1004.1.2 TOTAL OCCUPANT LOAD 202 OCC. (GREATEST TOTAL) REQUIRED EGRESS WIDTH with SPRINKLERS IBC TBL. 1005.1 STAIRS @ .3"/ OCC NA OTHER EGRESS @ .2"/ OCC 40.4" ACTUAL EGRESS WIDTH FLOOR PLANS STAIRS NA OTHER EGRESS 186" MAX ALLOW. TRAVEL DISTANCE with SPRINKLERS 250'IBC TBL. 1015.1 MAXIMUM ACTUAL TRAVEL DISTANCE88'FLOOR PLANS NUMBER OF EXITS REQUIRED 2 IBC TBL. 1018.1 NUMBER OF EXITS PROVIDED4 FLOOR PLANS MINIMUM ROOF COVERING CLASSIFICATION CLASS C IBC TBL. 1505.1 ADOPTED AND EFFECTIVE BUILDING CODES, w/ STATE AMENDMENTS 2014 INDIANA BUILDING CODE - 2012 INTERNATIONAL BUILDING CODE 2009 INDIANA ELECTRICAL CODE - 2008 NATIONAL ELECTRICAL CODE 2012 INDIANA PLUMBING CODE - 2006 INTERNATIONAL PLUMBING CODE 2014 INDIANA MECHANICAL CODE - 2012 INTERNATIONAL MECHANICAL CODE 2014 INDIANA FIRE CODE - 2012 INTERNATIONAL FIRE CODE 2010 INDIANA ENERGY CONSERVATION CODE 2009 INTERNATIONAL ACCESSIBILITY CODE 2014 INDIANA FUEL GAS CODE - 2012 INTERNATIONAL FUEL GAS CODE A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIIES - 2009 ICC CODE PLAN & DATACONTRACTOR NOTESCODE PLAN SCALE : 1/8" = 1'-0" OA101NEW CULVER'S RESTAURANT431 E Carmel DriveCarmel, IN 46032County of HamiltonDate:Revision:5-25-2022OLLMANN ASSOCIATES ARCHITECTS, P.C.200 South State StreetBelvidere, Illinois 61008815-544-7790 Phone© 2022K&J INVESTMENTS XVI, LLC1448 Conner StreetNoblesville, IN 46060Bob Goins: bgoins@indyculvers.com317-770-4656OWNER:Culver Franchising System, Inc.1240 Water StreetPrairie du Sac, WI 53578608-643-7980®2020-159 © OAA All rights reserved; any copying, transmittal or disclosure subject to OAA written approval. C7 01/13/23