HomeMy WebLinkAboutGN110 - FS-2 - For Reference Only4"4"2"45"3"7"8"31"4"4"8"
11
-0"4"4"24"5"3"8"1"8"8"47"5"8"7
-"12
-10"11
-""5"4"""10
-7"1
-2"1"13
-5"48"8"8"
PVC SLEEVE UNDER FLOOR KEEP DRY
DURING CONSTRUCTION SEAL BOTH
ENDS AFTER SODA LINE INSTALLATION
PVC SLEEVE UNDER FLOOR KEEP
DRY DURING CONSTRUCTION
SEAL BOTH ENDS AFTER SODA
LINE INSTALLATION
1" DIA. COPPER DRAIN LINES
BY FEC. LINES MUST BE
TRAPPED OUTSIDE OF THE
REFRIGERATED/FRO=EN
SPACES
INTERIOR WASTE OIL
SYSTEM BY OWNER. SEE
DETAILS ON SHEET P-1
VERIFY REQUIREMENTS
WATER FILTER OUT
WATER FILTER INLET
VERIFY ALL
REQUIREMENTS FOR
BAG IN BOX SYSTEM
AND SODA LINE RUNS
WITH SODA SUPPLIERREFRIGERATION CHASE NO
PLUMBING IN THIS SPACE
WATER FILTER SEE
DETAIL
VERIFY ALL PLUMBING
REQUIREMENTS Z/OWNER
FOR THESE AREAS
85.1
11"
85.385.4
25"
85.5
85.5
85.5
21
- 1"7"8
5"A.3
103.2
A.2
15D
15C
.2
75.2
3.2
75.3
80A.2
80D.1
80D.2
80D.3
84.3
8.3
51
1.1
1.2
1.3
25.2 2.2
0
1.3
1.2
12
0
1.1
15.3
7.3
7.27.1
20.2
30.1
30.3
30.2
30
2.1
12A
23.3
23.1
25.1
20.2 20.2
22.3 22.1
20.3
20.1
13
4.315B15A
33.2
3.33.2
3.1
1B 2B
11"
11"
ITEM PLUMBING CONNECTION SCHEDULE
1B 3" HUB DRAIN (CLEARWATER WASTE) STUB-UP 3" AFF
2B DRAINS TO HUB DRAIN LISTED FOR ITEM 1B
7.1 12" HW 14" AFF
7.2 3" HUB DRAIN STUB-UP " AFF
7.3 12" CW 14" AFF
12 34" BLACK IRON PIPE 24" AFF. FROM ABOVE. OUT TO ITEM 12A
12A 34" BLACK IRON PIPE " AFF. FROM ABOVE. IN FROM ITEM 12
13 WASHER AND DRYER BY OWNER VERIFY REQUIREMENTS
15.3 34" CW 30" AFF FROM ITEM 4 FLITER
15A " PVC SLEEVE STUB-UP 12" AFF OUT TO ITEM 15C
15B " PVC SLEEVE STUB-UP 12" AFF OUT TO ITEM 15D
15C " PVC SLEEVE STUB-UP 8" AFF FROM ITEM 15A
15D " PVC SLEEVE STUB-UP 8" AFF FROM ITEM 15B
1.1 12" HW 20" AFF (TWO LOCATIONS)
1.2 1 12" DW 20" AFF (TWO LOCATIONS)
1.3 12" CW 20" AFF (TWO LOCATIONS)
20.1 34" HW 14" AFF CONNECTS TO FAUCET AND SANITI=ER SYSTEM
20.2 2" DW 10" AFF (THREE LOCATIONS)
20.3 34" CW 14" AFF CONNECTS TO FAUCET
22.1 34" HW 14" AFF
22.3 34" CW 14" AFF
23.1 34" HW 14" AFF PROVIDE A 12" TEE FOR ITEM 25.1
23.3 34" CW 14" AFF CONNECTS TO ITEM 23
25.1 12" HW FROM ITEM 23.1 FOR CHEMICAL FEED SYSTEM
25.2 4" HUB DRAIN STUB-UP 3" AFF
2.1 34" HW 14" AFF BRANCH THRU BOOSTER TO DISHWASHER
30 12" MIXED H/C WATER 20" AFF FROM MIXING VALVE WATER TO BE 70-75 DEGREES F.
30.1 12" HW IN CEILING ABOVE EYE WASH STATION
30.2 1 14" DW 24" AFF
30.3 12" CW IN CEILING ABOVE EYE WASH STATION
32 MOP SINK AND H/C WATER FAUCET BY PC SEE FAUCET NOTES ON DRAWING P1
33 MIXED HOT AND COLD WATER THRU ITEM 32 FAUCET
51 34" N. GAS 18" AFF
0 1 14" N. GAS 18" AFF TWO LOCATIONS SEE GAS PIPING DETAIL 3/FS-2
3.2 3" HUB DRAIN STUB-UP 3" AFF
4.3 34" CW 0" AFF BRANCH TO ITEMS 15 A 84 8 - SEE DETAIL 2/FS-2
.2 3" HUB DRAIN STUB-UP 3" AFF
.3 34" CW " AFF BRANCH THRU MAIN FILTERS ITEM 4 TO ICE MAKER
A.2 DRAINS TO HUB DRAIN LISTED FOR ITEM 103.2
A.3 34 CW 14" AFF. BRANCH THRU MAIN FILTERS ITEM 4 TO ICE MAKER (OPTIONAL ITEM)
VERIFY Z/ EQUIPMENT SUPPLIER
75.2 DRAINS TO HUB DRAIN LISTED FOR ITEM 3.2
75.3 34" CW 18" AFF
80A.2 3" HUB DRAIN STUB-UP 8" AFF
80B.2 3" HUB DRAIN STUB-UP 8" AFF
80D.1 12" HW 20" AFF
80D.2 1 12" DW 20" AFF
80D.3 12" CW 20" AFF
84.3 34" CW 28" AFF CONNECTS TO ITEM 84 THRU MAIN WATER FILTER ITEM 4
85.1 34" HW 4" BELOW FINISHED CEILING W/ SHUT OFF VALVE
85.3 34" CW 4" BELOW FINISHED CEILING W/ SHUT OFF VALVE
85.4 (3) 2" SCHEDULE 40 PVC SLEEVES THROUGH FINISHED CEILING.
85.5 (3 LOCATIONS) - 2" SCHEDULE 40 PVC SLEEVE FROM ABOVE FINISHED CEILING TO
EXTERIOR OF BUILDING. SEE DETAIL "A" ON P-1.
3.1 1/2" HW 20" AFF.
3.2 1 1/2" DW 20" AFF.
3.3 1/2" CW 20" AFF.
.2 3" HUB DRAIN STUB-UP 8" AFF
.3 FILTERED CW FROM ITEM 15 THROUGH SODA LINE BUNDLE
7.3 FILTERED CW FROM ITEM 15 THROUGH SODA LINE BUNDLE
8.3 12" CW 28" AFF. CONNECTS TO ITEM 8 THRU MAIN EATER FILTER ITEM 4
103.2 3" HUB DRAIN STUB-UP 8" AFF
103.3 FILTERED CW FROM ITEM 15 THROUGH SODA LINE BUNDLE
104.3 FILTERED CW FROM ITEM 15 THROUGH SODA LINE BUNDLE
113.2 PC TO EXTEND DRAIN CONNECTION TO HUB DRAIN LISTED FOR ITEM 103.2
GENERAL NOTES
1.PC TO FURNISH AND INSTALL MIXING VALVE FOR ITEM 30 EYE WASH STATION.
2.SEE SHEET P-1 FOR FLOOR DRAIN LOCATIONS AND OTHER REQUIREMENTS.
3.WHERE DIMENSIONS ARE SHOWN TO EXTERIOR OF BUILDING THEY ARE SHOWN TO
INSIDE FACE OF EXTERIOR WALL. EXTERIOR WALL THICKNESS AND FOUNDATION
DETAILS MUST BE VERIFIED.
4.PC TO SEAL ALL PLUMBING PENETRATIONS THRU WALK-IN COOLER/FREE=ER WALL
AND CEILING PANELS.
FEC
1.FEC TO FIELD VERIFY ALL ROUGH-IN LOCATIONS AT EARLY DATE TO ENSURE
CORRECT PLACEMENTS AND QUANTITY. NOTE ANY CHANGES AND SUBMIT TO THE
ARCHITECT AND CONSULTANT FOR APPROVAL.
2.FEC TO COORDINATE Z/ PC ON EXISTING EQUIPMENT PLUMBING REQUIREMENTS.
PLUMBING CONTRACTOR
1.HEIGHTS LISTED ON ROUGH-IN SCHEDULE ARE TO THE CENTER LINE OF THE
ROUGH-IN. ALL DIMENSIONS ARE FROM FINISHED WALLS AND FLOORS.
2.WHERE POSSIBLE ROUGH-INS ARE TO BE CONCEALED IN THE WALL AND STUBBED
OUT AT THE HEIGHT INDICATED.
3.WHERE AN OPEN SITE (HUB DRAIN) IS SPECIFIED THE CONTRACTOR IS TO
TERMINATE THE DRAIN PIPING OVER CENTER OF DRAIN PER STATE AND LOCAL
CODES.
4.PROVIDE ALL WATER SUPPLY AND DRAIN LINES DRAIN FITTINGS FLOOR DRAINS
VALVES TRAPS UNIONS TAILPIECES PRESSURE REDUCING VALVES CHECK
VALVES SHOCK ABSORBERS PVC CONDUIT FOR BEVERAGE AND REFRIGERATION
LINES AS REQUIRED. PROVIDE GREASE TRAPS OR INTERCEPTORS SI=ED PER CODE
TO HANDLE LISTED VOLUMES AS INDICATED ON PLUMBING/MECHANICAL SCHEDULE
SHEET. IT SHALL BE THE RESPONSIBILITY OF THE PLUMBING ENGINEER TO SPECIFY
AND DETAIL THE REQUIREMENTS FOR CODE COMPLYING BACKFLOW/REDUCED
PRESSURE DEVICES AS REQUIRED BY STATE AND LOCAL CODES. THE PLUMBING
ENGINEER IS RESPONSIBLE FOR COORDINATION AND FEES REQUIRED FOR
APPROVAL OF DEVICES.
5.INSTALL ALL FAUCETS SPRAY UNITS LEVER WASTE DRAINS VACUUM BREAKERS
CHECK VALVES FLOW CONTROL VALVES TROUGH WATER INLETS WATER FILTERS
STRAINERS PRV VALVES T/P GAUGES FURNISHED BY THE FEC/KEC AS SHOWN ON
THE MECHANICAL SCHEDULES. EXPOSED PIPING AND FIXTURES SHALL NOT SHOW
TOOL MARKS. HORI=ONTAL PIPING SHALL BE A MINIMUM OF " AFF. ALL EXPOSED
PIPING ABOVE 34" AFF TO BE CHROME PLATED.
.COORDINATE Z/ BEVERAGE MACHINE PURVEYORS FOR PLUMBING REQUIREMENTS
ON PURVEYOR/SUPPLIER FURNISHED EQUIPMENT.
7.THE FIRE/FUEL GAS SHUT-OFF SOLENOID VALVE IS PROVIDED BY HVAC AND
INSTALLED BY PC/MC.
8.ALL FEED SUPPLY PIPING SHUT-OFF VALVES AND DRIP LEGS ARE PROVIDED BY
GAS PIPING CONTRACTOR.
.GAS PIPING CONTRACTOR TO PROVIDE GAS SERVICE TO FOODSERVICE
EQUIPMENT AT A MAXIMUM OF 14" W.C. FOODSERVICE EQUIPMENT CONTRACTOR
(FEC) TO FURNISH REGULATORS FOR EQUIPMENT THAT REQUIRE PRESSURES
BELOW 14" W.C. GAS PIPING CONTRACTOR TO INSTALL THE REGULATORS
FURNISHED BY FEC AS INDICATED ON THE FOODSERVICE
MECHANICAL/ELECTRICAL/PLUMBING SCHEDULE (M.E.P.).
10.FEC TO FURNISH ALL SPECIFIED FLEX GAS HOSE/RESTRAINING CABLE KITS TO THE
GAS PIPING CONTRACTOR FOR INSTALLATION AS INDICATED IN THE
SPECIFICATIONS AND ON THE M.E.P. SCHEDULE SHEETS.
11.OPEN SITE HUB DRAINS ARE REQUIRED. DIMENSIONS SHOWN ON THIS PLAN ARE
FOR HUB DRAINS. IF FLOOR SINKS ARE A CODE REQUIREMENT VERIFY LOCATIONS
WITH EQUIPMENT SUPPLIER BEFORE FLOOR SLAB POUR
FEC TO SEAL ALL PLUMBING
PENETRATIONS THRU WALK IN
COOLER/FREE=ER WALL AND
CEILING PANELS
-8 1/4"80B.2 10
-2"HALL
10CUSTOMER ORDER AREA105DINING
101
DRINKS CONDIMENTS
102
DRIVE-THRU SERVICE
104
SUNDAE ASSEMBLY
111
ENTRY
10
MEN
107
WOMEN
108
MOP ROOM
118
OFFICE
117
DRY GOODS
115
KITCHEN 112DISHWASHING113PREP AREA114EMPLOYEE TOILET
11
UTILITY ROOM
11
COOLER
120
FREE=ER
121
ENTRY
103
CUSTOMER SERVICE110PLUMBING SYMBOLS
HW HOT WATER
CW COLD WATER
DW DIRECT WASTE
H.D.HUB DRAIN
G GAS
AFF ABOVE FINISHED FLOOR
PWC EXTERIOR POWER WASHER
CONNECTION
VERIFY ALL
PLUMBING
REQUIREMENTS
WITH OWNER8"32
.3
35
-10"
7"
13
-2"
8
-11"13
-8"4"4"14"33"113.2 10"8"20
- 1/4"
FOODSERVICE PLUMBING PLAN - METRO L 2022 PROTOTYPE
SCALE: 1 4" = 1'-0"
GENERAL NOTES
1.PLUMBING CONTRACTOR TO FLUSH ALL LINES OF FOREIGN MATTER BEFORE FILTER CARTRIDGE
INSTALLATION.
2.DO NOT USE SOLID PIPING TO WATER BOOSTER.
3.VERIFY PLYWOOD BACKING IN WALL Z/ GC BEFORE MOUNTING BOOSTER.
4.PROVIDE UNIONS ON BOTH SIDES OF BOOSTER PUMP AND WATER FILTER.
5.IF PEX PIPING REQUIRED PER LOCAL CODES ON ANY FILTERED WATER SUPPLY LINES A 1" DIA. MINIMUM
LINE SI=E IS TO BE USED. ICE MACHINE TO BE DIRECT NO TEE
S. ALL FITTINGS TO BE FULL FLOW. DO
NOT REDUCE LINE SI=E AT FITTINGS.
EVAPORATOR
COIL
COPPER DRAIN
LINE
P-TRAP
OPEN SITE
DRAIN
VAPOR SEAL
GENERAL REFRIGERATION DRAIN NOTES
1.REFRIGERATION CONTRACTOR TO FURNISH AND INSTALL 1"
COPPER DRAIN LINE DRAIN LINE HEAT TAPE WITH A 30
WATTS/FOOT RATING AND 1" ID ARMAFLEX PIPE INSULATION
ON FREE=ER ONLY.
2.RUN PIPE WITH A 1/2" 1
PITCH.
3.SEAL ANY AND ALL PIPING PENETRATIONS.
PC TO PROVIDE 34" UNION TYPE FITTINGS
ON EITHER SIDE OF BOOSTER PUMP
TANK FURNISHED AND INSTALLED BY
PEPSI
34" MIN. INCOMING WATER SUPPLY
COPPER INCOMING WATER SUPPLY
BUILDING WALL IN MECHANICAL ROOM
SHUT-OFF VALVES
AS REQUIRED
34" MIN. DIA. COPPER WATER FILTER BYPASS CIRCUIT
SHUT-OFF VALVES
AS REQUIRED
CUNO DP20 WATER
FILTER BY FOODSERVICE
EQUIPMENT SUPPLIER
34" DIA. COPPER FILTERED DESCALED WATER OUT TO ICE MAKERS
COFFEE MAKER ICED TEA ITEMS A 84 8
34" DIA. FILTERED WATER OUT TO ITEM 15 BAG IN BOX
AREA. PEPSI TO RUN FILTERED WATER OUT TO
SELF-SERVE SODA STATION ITEMS 7 103 104
BYPASS
SHUT-OFF VALVES
AS REQUIRED
DETAIL - WALK IN DRAIN LINE
NTS
1
FS-2
SCHEMATIC - WATER FILTER ICE,
SODA, BEVERAGE EQUIPMENT
NTS
2
FS-2
VENT REGULATOR PER ALL LOCAL
CODES KEEP ELBOWS TO
MINIMUM AND DO NOT REDUCE
MECHANICAL GAS SHUT-OFF VALVE
BY MC VERIFY LOCATION AND GAS
PRESSURES Z/ FIRE SYSTEM
INSTALLER
785 MBTU AT 2# INCOMING
GAS PRESSURE BTU LOAD
FOR GRILL AND FRYERS ONLY
ITEM 4 EXHAUST HOOD
BY HVAC
34" TO FEED ITEM 51 GRIDDLE
7"-" W.C. GAS PRESSURE AT
CONNECTION
GAS PIPING ROUGH-IN FOR ITEMS
51 AND 0 SEE SHEET FS-2 FOR
EXACT LOCATIONS AND HEIGHTS
1 14" TO FEED ITEM 0 FRYERS 7"-"
W.C. GAS PRESSURE AT
CONNECTION
ITEM 5 EXHAUST HOOD BY HVAC
CLOSURE PANELS BY HVAC
1 14" GAS PIPING BRANCH
TO TWO CONNECTIONS
FOR ITEM 0 DO NOT
REDUCE
TRUSS BEARING AT 10
-0"
VERIFY GAS PRESSURE OUT TO ITEMS 51 AND 0
GENERAL NOTES
1.GAS PRESSURE REGULATOR TO BE A MINIMUM OF 120" AWAY FROM EQUIPMENT. MAINTAIN 1 12" PIPE SI=E TO
EQUIPMENT DROPS. KEEP ELBOWS TO A MINIMUM.
2.GAS PRESSURE REGULATOR BY M.C. REGULATOR MUST BE AD-USTABLE AND MUST HAVE MINIMUM OF 1 12" OUTLET.
FINISHED CEILING AT 8
-0"
MAINTAIN CONSTANT FLOWING
PRESSURE AT EQUIPMENT CONNECTION
DETAIL - NATURAL GAS PIPING AT COOKLINE
NTS
3
FS-2
OPEN SITE HUB DRAIN
TRAPPED BELOW FLOOR
HARD PIPED DRAIN
FROM EQUIPMENT
CONNECTION BY PC
DRAIN SHUT-OFF
VALVE BY PC
AIR GAP BETWEEN EQUIPMENT
DRAIN AND SITE DRAIN PER
LOCAL CODES
REMOVABLE
CABINET BOTTOM
DETAIL - OPEN SITE DRAIN PIPING AT CABINET BASE
NTS
4
FS-2
2# HIGH PRESSURE GAS BUILDING
DELIVERY RECOMMENDED. IF A LOW
PRESSURE SYSTEM IS REQUIRED BY
LOCAL CODES OR UTILITIES 11" WC GAS
PRESSURE IS REQUIRED TO THE GRILL
AND FRYER AREA
HUB DRAIN DETAIL
8" X 8" FLOOR SINK WITH
REMOVABLE STRAINER
HARD PIPED DRAIN
FROM EQUIPMENT
CONNECTION BY PC
DRAIN SHUT-OFF
VALVE BY PC
RECESS IN EQUIPMENT CURB.
VERIFY EXACT LOCATION WITH
FOODSERVICE EQUIPMENT
SUPPLIER
REMOVABLE
CABINET BOTTOM
FLOOR SINK DETAIL
AIR GAP BETWEEN
EQUIPMENT DRAIN AND
SITE DRAIN PER LOCAL
CODES
FLOORING MATERIAL
IN RECESS
HUB DRAINS ARE REQUIRED FOR OPEN
SITE DRAINS. IF FLOOR SINKS ARE
REQUIRED BY LOCAL CODES. VERIFY
EXACT LOCATIONS WITH FOODSERVICE
EQUIPMENT SUPPLIER3"4"4"8
-1"28"
FS-2
SheetWARNING!: These plans are for the exclusive use of Culver Franchising System, LLC and authorized franchise holders only. No part of these plans or the design they represent may be duplicated or reproduced without permission ofCulver Franchising System, LLCDate Revision ByDate:
Drawn By:
Project No.
Contents:Sheet
V. Young
Culver Franchising
System, LLC
1240 Water Street
Prairie du Sac, WI 53578
608-643-7980
FOODSERVICE
PLUMBING
PLANMETRO L - 2022CULVER FRANCHISING SYSTEM, LLCJan. 1, 2022
Metro L - 2022 PROTOTYPE PLANSFRONT
LEFT SIDE
RIGHT SIDE
REAR
SEE SITE PLAN FOR
NORTH ORIENTATION
PLUMBING CONNECTION SCHEDULE
INFORMATION IS PROVIDED ON
SHEET P103 PLUMBING SCHEDULE
THIS INFORMATION IS PROVIDED IN
PLUMBING NOTES ON SHEET P103
WALK-IN DRAIN LINE DETAIL IS
PROVIDED ON SHEET P103
WATER FILTER SCHEMATIC IS INCLUDED ON SHEET P302
SEE SHEET P103 FOR FOOD
SERVICE PLUMBING ROUGH-INS
SEE GAS PIPING PLAN & DETAIL ON P102;
GAS PIPING ISOMETRIC ON P302
01/13/23