HomeMy WebLinkAboutGN111 - FS-3 - For Reference OnlyS31"3"1 2"1 4""31 "1 0"
1 0"
2"
8-1 "40"1 0"1 1 "44"1 1 "1 2"3"34"32"1 8"33"25"1 3"
7"
-8"23"1 "21 "
1 0"1 3"
1 4"1 2"23"28-0"48-2"28"20"8"85A24"1 5"
SEE SHEET E-4 FOR CASH
REGISTER REQUIREMENTS IN
THIS AREA
REFRIGERATION CHASE
NO ELECTRICAL IN THIS
SPACE
FOUR SWITCHES
STACKED VERTICALLY
ON END OF WALL. SEE
DETAIL 2 ON THIS
DRAWING
VERIFY ALL REQUIREMENTS FOR
BAG IN BOX SYSTEM AND SODA
LINE RUNS Z/ SODA SUPPLIER
HEATED AIR VENT
CONNECTION
POINT FREE=ER
ONLY
DOOR/LIGHT ASSEMBLY
CONNECTION POINTS
COIL CONNECTION
POINT
COIL DRAIN LINE HEAT
TAPE CONNECTION
POINT
EXTRA LIGHT
CONNECTION
POINTS
COIL
CONNECTION
POINT THREE POLE
SINGLE THROW
SWITCH FOR
COIL CONTROL
EXTRA LIGHT
CONNECTION
POINTS
KITCHEN FAN CONTROL CENTER
(KFCC) MOUNTED ABOVE FINISHED
CEILING SEE NOTES ON SHEET
M-5
EC TO SEAL ALL ELECTRICAL
PENETRATIONS THRU WALK-IN
COOLER/FREE=ER WALL AND
CEILING PANELS
85
85A
VERIFY ALL ELECTRICAL
REQUIREMENTS
Z/OWNER FOR THESE
AREAS
85A
THREE POLE SINGLE
THROW SWITCH FOR
COIL CONTROL
1 1 3
1 03 1 04A
1 1 4
1 0
1
1 00
4
3
7
72
74
5
75
80C
1 21
80C
71
70 83
1 2A
3 3B
28A
28
1
1
34
0
81
GP
51
4
5
1
28
41
43
3GP
37
A
28B
7
7
25A
1 5 1 3
25
2
1 2
2D2B2A
1 D1 B1 A
80A
5
80B
80C
84
8
0A
20"
485"GP
HALL
1 0CUSTOMER ORDER AREA1 05
DINING
1 01
DRINKS CONDIMENTS
1 02
DRIVE-THRU SERVICE
1 04
SUNDAE ASSEMBLY
1 1 1
ENTRY
1 0
MEN
1 07
WOMEN
1 08
MOP ROOM
1 1 8
OFFICE
1 1 7
DRY GOODS
1 1 5
KITCHEN 1 1 2DISHWASHING1 1 3PREP AREA1 1 4
EMPLOYEE TOILET
1 1
UTILITY ROOM
1 1
COOLER
1 20
FREE=ER
1 21
ENTRY
1 03
CUSTOMER SERVICE1 1 0
80C 50"AD-USTABLE S/S OVERSHELVES
S/S "C" CHANNEL TRIM
ITEM 3 OUTLET
GENERAL PURPOSE OUTLET ITEM 37 OUTLET
GENERAL PURPOSE OUTLET
ITEM OUTLETS
GENERAL NOTES
1 .SEE SHEETS E-1 E-2 E-3 AND E-4 FOR OTHER POWER PHONE AND COMMUNICATION
REQUIREMENTS. VERIFY LOCATIONS WITH OWNER.
2.WHERE DIMENSIONS ARE SHOWN TO THE EXTERIOR OF THE BUILDING THEY ARE SHOWN TO
THE INSIDE FACE OF THE EXTERIOR WALL. EXTERIOR WALL THICKNESS AND FOUNDATION
DETAILS MUST BE VERIFIED.
3.EC TO SEAL ALL ELECTRICAL PENETRATIONS THRU WALK-IN COOLER/FREE=ER WALL AND
CEILING PANELS.
FEC
1 .FEC TO FIELD VERIFY ALL ROUGH-IN LOCATIONS AT EARLY DATE TO ENSURE CORRECT
PLACEMENTS AND QUANTITY. NOTE ANY CHANGES AND SUBMIT TO THE ARCHITECT AND
CONSULTANT FOR APPROVAL.
2.FEC TO COORDINATE Z/ EC ON EXISTING EQUIPMENT ELECTRICAL REQUIREMENTS.
ELECTRICAL CONTRACTOR
1 .HEIGHTS LISTED ON ROUGH-IN SCHEDULE ARE TO THE CENTER LINE OF THE ROUGH-IN. ALL
DIMENSIONS ARE FROM FINISHED WALLS AND FLOORS.
2.WHERE POSSIBLE THE ROUGH-INS ARE TO BE CONCEALED IN THE WALL OR FLOOR AND
STUBBED OUT AT THE HEIGHTS INDICATED.
3.PROVIDE ALL RECEPTACLES CONDUIT CONTACTORS CONTROLLERS SWITCHES
DISCONNECTS STARTERS ETC. UNLESS SO INDICATED IN THE ELECTRICAL SCHEDULE AS
FURNISHED BY THE FEC FOR INSTALLATION BY THE EC.
4.INSTALL DEVICES FURNISHED BY FEC AND INDICATED ON THE ELECTRICAL/MECHANICAL
SCHEDULE.
5.COORDINATE WITH BEVERAGE MACHINE PURVEYOR FOR ELECTRICAL REQUIREMENTS ON ALL
PURVEYOR FURNISHED EQUIPMENT.
.EC TO PROVIDE G.F.I. STYLE OUTLETS WHERE CODE DICTATES THEY SHOULD BE IN WET
AREAS.
7.REFRIGERATION LINES ARE TO BE RUN IN WALLS PRIOR TO ELECTRICAL RUNS.
ITEM ELECTRICAL CONNECTION SCHEDULE
1 A 1 1 5/1 --BOX 1 00" AFF
1 B 1 1 5/1 --BOX 1 00" AFF
1 C 208/3 --BOX 42" AFF ON BUILDING ROOF VERIFY LOCATION Z/ GC
1 D 1 1 5/1 --BOX 1 00" AFF
2A 1 1 5/1 --BOX 1 00" AFF
2B 208/1 --BOX 1 1 2" AFF
2C 208/3 --BOX 42" AFF ON BUILDING ROOF VERIFY LOCATION Z/ GC
2D 1 1 5/1 --BOX 1 00" AFF
7 1 1 5/1 DCO 48" AFF TWO LOCATIONS
1 1 5/1 S.O. 48" AFF TWO LOCATIONS
A 1 1 5/1 S.O. 30" AFF TWO LOCATIONS SEE ELEVATION DETAIL BELOW
1 2 1 1 5/1 D.O. " AFF OPTIONAL VERIFY Z/ OWNER
1 2A BLANK 2X4 --BOX 8" AFF PROVIDE 34" EMPTY CONDUIT TO ABOVE FINISHED
CEILING VERIFY Z/ OWNER
1 3 VERIFY Z/ OWNER ON WASHER/DRYER REQUIREMENTS
1 5 1 1 5/1 D.O. 0" AFF VERIFY Z/ SODA SUPPLIER
1 1 1 5/1 GFCI D.O. 24" AFF TWO LOCATIONS
25 1 1 5/1 --BOX 70" AFF
25A SWITCH FOR EXHAUST HOOD FAN 50" AFF VERIFY Z/ HVAC
2208/3 --BOX 1 " AFF
28 1 1 5/1 DEDICATED ISOLATED 24 HOUR CIRCUIT AT CEILING VERIFY Z/ FIRE
SYSTEM INSTALLER TWO LOCATIONS
28A REMOTE PULL STATION. VERIFY LOCATION WITH LOCAL CODES
28B REMOTE PULL STATION. VERIFY LOCATION WITH LOCAL CODES
34 1 1 5/1 D.O. 0" AFF
3208/1 S.O. TWO LOCATIONS 48" AFF AND 4" AFF
37 1 1 5/1 D.O. 1 " AFF
41 1 1 5/1 S.O. 48" AFF
41 A 208/1 --BOX ROUGH-IN AND COVER ABOVE CEILING FOR FUTURE USE
41 B 208/1 --BOX ROUGH IN AND COVER ABOVE CEILING FOR FUTURE USE
43 1 1 5/1 S.O. 48" AFF
48 1 1 5/1 D.O. 48" AFF
4USER INTERFACE FOR EXHAUST FANS MUST BE INTERLOCKED Z/ COOKLINE
EQUIPMENT ITEMS 51 0 AND KFCC
51 1 1 5/1 D.O. 1 8" AFF
51 1 5/1 D.O. 24" AFF
58 1 1 5/1 --BOX 0" AFF
5SEE ITEM 4 COMMENTS
0 1 1 5/1 D.O. 24" AFF
0A 1 1 5/1 D.O. 24" AFF
1 1 1 5/1 D.O. 24" AFF
3 208/3 SWITCHES THREE LOCATIONS COORDINATE INSTALL Z/
REFRIGERATION SYSTEM INSTALLER
3A 208/3 --BOXES 42" AFF ON BUILDING ROOF VERIFY LOCATION Z/ GC
3B 1 1 5/1 SWITCH COORDINATE INSTALL Z/ REFRIGERATION SYSTEM INSTALLER
5 1 1 5/1 D.O. 42" AFF
208/1 --BOX 0" AFF
A 1 1 5/1 --BOX 4" AFF OPTIONAL. VERIFY WITH OWNER
A.1 208/1 --BOX ON BUILDING ROOF OPTIONAL. VERIFY WITH OWNER
1 1 5/1 D.O. 24" AFF TWO LOCATIONS
70 208/3 S.O. 24" AFF.
71 1 1 5/1 D.O. 48" AFF
72 1 1 5/1 D.O. 42" AFF TWO LOCATIONS
74 1 1 5/1 D.O. 24" AFF
75 1 1 5/1 D.O. 24" AFF
80A 1 1 5/1 --BOX 24" AFF
80B 208/1 --BOX 24" AFF E.C. TO PROVIDE CONDUIT FOR CONNECTION
80C 1 1 5/1 D.O. 48" AFF FOUR LOCATIONS
81 1 1 5/208/1 S.O. 24" AFF
83 1 1 5/1 D.O. 0" AFF
84 1 1 5/208/1 S.O. 48" AFF
85 208/1 S.O. " BELOW FINISHED CEILING.
85A (3 LOCATIONS) - 1 " SCHEDULE 40 PVC SLEEVE FROM ABOVE FINISHED
CEILING TO EXTERIOR OF BUILDING. SEE DETAIL "A" ON P-1 .
1 1 1 5/1 DEDICATED ISOLATED STUB-UP 8" AFF BRANCH TO OUTLETS
MOUNTED IN COUNTER AS SHOWN
3 1 1 5/1 --BOX 1 8" AFF WIRE TO OUTLET FOR ITEM MOUNTED INSIDE
CABINET
4 1 1 5/1 D.O. 48" AFF
1 1 5/1 D.O. 1 4" AFF
7 1 1 5/1 D.O. 1 4" AFF. SAME CIRCUIT AS ITEM
8 1 1 5/1 S.O. 48" AFF
1 00 1 1 5/1 --BOX " AFF LIGHTS TO BE ON/OFF PENDANTS VERIFY LOCATION
OF DISPLAY CASE
1 03 1 1 5/1 D.O. 20" AFF
1 04 1 1 5/1 D.O. 20" AFF. SAME CIRCUIT AS ITEM 1 03
1 01 1 5/1 D.O. 7" AFF
1 1 3 1 1 5/1 D.O. 42" AFF
1 1 4 1 1 5/1 D.O. 24" AFF
1 21 1 1 5/1 D.O. 24" AFF.
1 23 1 1 5/1 D.O. 24" AFF
G.P.1 1 5/1 DCO 24" AFF. (20.0) AMP VARIOUS LOCATION
1 2"1 3"22"27"7"1 "3""
BULK CO2 STORAGE MAY REQUIRE
AN ALARM SYSTEM AND PERMITS.
VERIFY ALL REQUIREMENTS WITH
LOCAL AUTHORITIES AND
INSTALLERSELECTRICAL SYMBOLS
--BOX ELECTRICAL -UNCTION BOX
S.O.SINGLE OUTLET
D.O.DUPLEX OUTLET
AFF ABOVE FINISHED FLOOR
SW SWITCH
LIGHT VAPOR PROOF WALK-IN DOOR LIGHT PROVIDED
BY FEC EC TO WIRE AND INSTALL
LIGHT ADDITIONAL VAPOR PROOF LIGHT PROVIDED
BY FEC EC TO WIRE AND INSTALL
--BOX HOOD INTERFACE
-3"1 3"""41 A GP
58
41 B
38"
DETAIL - DINNER MAKE
STATION OUTLETS
NTS
1
FS-3
FOODSERVICE ELECTRICAL PLAN - METRO L - 2022 PROTOTYPE
SCALE: 1 4" = 1'-0""4"
"
1 "43"S27"1 "1 "
S S
S S3-3"3"1 23
ITEM 3 CORDS TO MACHINE WITH
0 DEGREE CONNECTORS AT WALL
FINISHED CEILINGCORDS TO BE AS
CLOSE TO END OF
WALL AS POSSIBLE
ELECTRICAL NOTE
EC TO FURNISH AND INSTALL FOUR HUBBELL NHC1 037 CONNECTORS AT WALL CORDS FROM THE CONNECTORS TO
THE MACHINE CONNECTION POINT THREE HUBBELL HBL781 0D SWITCHES FOR MOTOR CONTROL AND ONE HUBBELL
#1 221 W SWITCH FOR HOPPER REFRIGERATION CONTROL. MOUNT SWITCHES IN END OF WALL. FURNISH AND INSTALL
FOUR HUBBELL MX1 050S FLIP COVERS WITH LOCKING TABS
FINISHED FLOOR
DETAIL - CUSTARD MACHINE SWITCHES
NTS
2
FS-3
MOTOR CONTROL
SWITCHES WITH
WEATHERPROOF
LOCKING COVERS3"""""OUTLINE OF
CUSTARD MACHINE
KEEP CORDS OFF
OF FLOORSIDE VIEW END VIEW 27"8
COORDINATE
CONSTRUCTION OF
WALL WITH EC FOR
EASE OF SWITCH
INSTALLATION IN
END OF WALL
FS-3
SheetWARNING!: These plans are for the exclusive use of Culver Franchising System, LLC and authorized franchise holders only. No part of these plans or the design they represent may be duplicated or reproduced without permission ofCulver Franchising System, LLCDate Revision ByDate:
Drawn By:
Project No.
Contents:Sheet
V. Young
FRONT
LEFT SIDE
RIGHT SIDE
REAR
SEE SITE PLAN FOR
NORTH ORIENTATION
Culver Franchising
System, LLC
1240 Water Street
Prairie du Sac, WI 53578
608-643-7980
FOODSERVICE
ELECTRICAL
PLANMETRO L - 2022CULVER FRANCHISING SYSTEM, LLCJan. 1, 2022
Metro L - 2022 PROTOTYPE PLANSGENERAL NOTES INFORMATION BELOW IS PROVIDED IN GENERAL NOTES ON SHEET E102
ELECTRICAL CONNECTION SCHEDULE
INFORMATION IS PROVIDED ON
SHEET E201 ELECTRICAL SCHEDULE
SEE G1 / E103 FOR THIS DETAIL
SEE G2 / E103 FOR
THIS DETAIL
SEE SHEET E103 FOR FOOD SERVICE ELECTRICAL ROUGH-INS
SEE SHEET E103 FOR GENERAL PURPOSE POWER PLAN
01/13/23