Loading...
HomeMy WebLinkAboutA010-FRONT ELEVATIONBRICK and STONE LINTEL SCHEDULE 48" HIGH SPAN WINDOW *STONE*BRICKAll Lintels: 4" Minimum bearing required each end * Brick is based on 40psf and Stone is based on 60psf ** Any lintels not described by the above parameters shall be specifically designed. LINTEL SIZE36" HIGH ABOVE Up to 6'-0" Up to 8'-3" Up to 9'-3" Up to 16'-3" Up to 6'-0" Up to 8'-3" Up to 9'-3" Up to 16'-3" L7 x 4 x 3/8 L8 x 4 x 1/2 L8 x 4 x 1/2 L6 x 4 x 5/16 L5 x 3 1/2 x 5/16 L3 1/2 x 3 1/2 x 1/4 L7 x 4 x 3/8 **per Design L5 x 3 1/2 x 5/16 L4 x 3 1/2 x 1/4 L7 x 4 x 3/8 **per Design **per Design**per Design L6 x 4 x 3/8 L8 x 4 x 1/2 ---- ---- -------- ---- ---- -------- ---- ---- ---- ---- ---- ---- ---- ---- BRICK VENEER 12 12 12 12 GABLE BRACKET D3 8" TRIM (RIPPED) D 7.03 E 7.01 2640 FIXED8" TRIM8" TRIM 6" TRIM W/ BLACK-OUT 8" TRIM 8" TRIM (RIPPED) DOUBLE ROWLOCK (PULL 3/4) 8" TRIM 4" TRIM BRICK SILL BRICK SILL 8" TRIM RE: DETAIL A/7.03 12'-3"3'-7 1/4"3'-7 1/4"BRICK SILL 8" TRIM (RIPPED) TYP. ELEVATION 'Y' 12 12 12 12 10'-1"RESIDENCE FOR:Sheet InformationHouse Name: Series: Plan No.: Job Number: Drawing Date: Coord Name: Coord Phone: Drawing Scale: 1/8" = 1'0" Contract Drawn By: ( ) The Drees Company. All Rights Reserved. Space for Architect Seal 900 East 96th Street, Suite 100, Indianapolis, IN 46240 Phone: [317] 347-7300 Born on Date: CDs Drawn By: Copyright © THIMMAPPA 13722 FOXDALE LAKE DRIVE INDIANAPOLIS GALLERY HOMES IGA-0576-00 12/8/22 LJR SERIES_NM PLAN_NM 6.01 Elevation "Y" Front Elevation 859.578.4290 the LANGDON LJR 02/14/2020 WAB 2020 2019 General Notes: 1. REFER TO SHEET 0N.1 FOR GENERAL NOTES. 2. ROOFING MATERIAL PER SELECTIONS. 3. CONTACT M&K ENGINEERING FOR HEADER SIZE/BRICK SUPPORT IF GRADE DROPS AND THE AMOUNT OF BRICK OVER GARAGE DOOR SHOWN ON CURRENT ELEVATION IS NO LONGER ACCURATE TYPICAL TRIM: 6" FASCIA (ALL SIDES) (FRONT ONLY, UNLESS OTHERWISE NOTED) 8" FRIEZE Key Notes: 1 2 3 4 -- -- -- -- 01/26/23