Loading...
HomeMy WebLinkAboutGN010-COVER PAGE_SQUARE FOOTAGERESIDENCE FOR:Sheet InformationHouse Name: Series: Plan No.: Job Number: Drawing Date: Coord Name: Coord Phone: Drawing Scale: 1/8" = 1'0" Contract Drawn By: Space for Architect Seal 900 East 96th Street, Suite 100, Indianapolis, IN 46240 Phone: [317] 347-7300 Born on Date: CDs Drawn By: THIMMAPPA 13722 FOXDALE LAKE DRIVE INDIANAPOLIS GALLERY HOMES IGA-0576-00 12/8/22 LJR SERIES_NM PLAN_NM 0C.1 Elevation "Y" Cover Sheet 859.578.4290 the LANGDON LJR 02/14/2020 WAB Division: INDIANAPOLIS Building Code: 2020 INDIANA Residential Code Redraws Plan Review: 12/14/22 -WINDOW IN MASTER BATH -FLOOR BREAK BETWEEN FOYER AND FAMILY ROOM -REMOVE WINDOWS AND HARDWARE FROM GARAGE DOOR -3050 S/H BASEMENT WINDOWS -S.G.D. AND GARAGE TO HOME DOOR 8' TALL -REMOVE CEILING FAN R/I AND SWITCHES FROM BEDROOM #5 -3050 S/H WINDOWS AT SECOND FLOOR -CONTROL JOINTS AT BASEMENT Plan Review: 12/29/22 -UPDATED STRUCTURE PER ENGINEERING REDLINES Customer Plan Review Signature I understand that my new Drees home will be built in general comformance to the plans, specifications, selections and the Purchase Agreement, all of which I have reviewed and approved. This set of plans may not reflect the elevations or options for my house. Drees draws the standard plans complete with the most common options. The subcontractor's sets will show only the options I selected in my selection sheets. I have reviewed the plot plan for my house and understand that there may be some field adjustments as to the exact location of the house on the lot. I further understand that my home will not be built exactly like any other Drees home or Model and that some minor variations from my plans and specifications may occur since every home that is built has it's own set of unique construction problems that must be dealt with as the home is being built. Customer: ______________________________________________ Date: _____________ Customer: ______________________________________________ Date: _____________ Architecture Plan Review: No Comments Items drawn on any drawings and not written in the contract selctions WILL NOT be included in the site specific drawings.See Comments Customer Request: Building Height: As Required Brick Calculations: Sheet X.XX Fenestration Calculations: Total Wall Square Footage: ________ Total Window Square Footage:________ Total Fenestration %: ________ Design Solution:Reason For Modification:Comments: Square Footage Square Footage total may vary by +1 SF due to automated rounding of first and second floor area 4. XXX 3. XXX 4. XXX 3. XXX 4. XXX 3. XXX 4. XXX 3. XXX 2. XXX 1. 4020 SLIDER AT FIRST FLOOR FULL BATH 2. XXX 1. 3020 SLIDER PROVIDED 2. XXX 1. CANNOT FIT 4' WINDOW IN 4' SPACE 2. 1. XXX PLEASE ADVISE Index to the Drawings Sheet No.Sheet Name 0C.1 Cover Sheet 0N.1 General Notes 0P.1 Plot Plan 1.01 Foundation Plan 1.02 Lower Level Framing Plan 1.03 Lower Level Mechanical Plan 2.01F First Floor Framing Plan 2.01S First Floor Structural Plan 2.02F Second Floor Framing Plan 2.02S Second Floor Structural Plan 2.03F Third Floor Framing Plan 2.03S Third Floor Structural Plan 2.04 Roof Plan 3.01 First Floor Subfloor Plan 3.02 Second Floor Subfloor Plan 4.01 First Floor Mechanical Plan 4.02 Second Floor Mechanical Plan 4.03 Third Floor Mechanical Plan 5.01 Building Section 6.01 Front Elevation 6.02 Garage Side Elevation 6.03 Rear Elevation 6.04 Side Elevation 7.01 House Specific Details 7.02 House Specific Details 7.03 House Specific Details 7.04 House Specific Details 7.05 House Specific Details Living Areas First Floor 2302 SF Second Floor 2056 SF 4358 SF Unfinished Areas Covered Entry 133 SF Garage 986 SF Rear Deck 234 SF Unfinished Basement 2303 SF 3656 SF Plan Review: 1/16/23 -LABEL ALL GFCI OUTLETS -REMOVE GRIDS FROM WINDOWS -ADD WINDOWS AT BATHS PER REDLINES -ADD WINDOWS AT BACK OF GARAGE -ADD FIXED WINDOWS ABOVE GARAGE DOORS -MOVE LAUNDRY WINDOW TO ALIGN WITH GARAGE DOOR AND WIDNOW 01/26/23