HomeMy WebLinkAboutLeishman Connection Details A-436" PERMA COLUMN
PERMA COLUMN 16" BASE
PER CODE
6x6 TREATED POST
2 1
2" DIAMETER THROUGH BOLTS
COMPACTED EARTH EVERY 12"
COMPOSITE DECK
SECTION TYP.
5 1
2" MIN. FOR BEAM SPLICES
WHERE POST BEAR ON CONCRETE FOOTINGS IN ACCORDANCE WITH SECTION R403 AND FIGURE 507.3 LATERAL
RESTRAINT SHALL BE PROVIDED BY MANUFACTURED CONNECTORS OR A MIN. POST EMBEDMENT OF 12 INCHES
305MM IN SURROUNDING SOILS OR CONCRETE PIERS. OTHER FOOTING SYSTEMS SHALL BE PERMITTED
EXCEPTION WHERE EXPANSIVE CMPRESSIBLE SHIFTING OR OTHER QUESTIONABLE SOILS ARE PRESENT
SURROUNDING SOILS SHALL NOT BE RELIED ON FOR LATERAL SUPPORT.
LEDGER CONECTION DETAIL
EXISTING 2X4 BOTTOM PLATE
NEW 2X8 TRTD. LEDGER
REMOVE SHEATING AND SIDING FOR
TIGHT CONNECTION TO BAN BRD.
8" JOISTS HANGER NAILED PER CODE
2X8 JSTS @ 16" O.C.
EXSTNG 2X10 FLR JSTS.
2" LAG SCREWS
WTH WASHER
2" MIN. SPCNG
FLASHNG UNDER SIDING AND
DECK
1112"2'-41
2" 1'-6" 3'STAIR DETAIL
6x6 CEDAR POST
SIMPSON STRONG TIE
DBL. 2X12 BEAM NOTCHED7 14"RISE
RUN
36" PERMA COLUMN
A101
2"
CONNECTION DETAILS
Not To Scale
sheet:
10.11.21 A-4drawn by:
checked by:
RMC
RMC
GENERAL NOTES:
1. VERIFY UNDERGROUND UTILITY LOCATIONS PRIOR TO PLANT
INSTALLATION.
3. VERIFY FIELD CONDITIONS, NOTIFY LANDSCAPE DESIGNER OF
ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD
CONDITIONS.
4. REGRADE, REPAIR AND REPLANT ALL AREAS DISTURBED BY
CONSTRUCTION, THIS INCLUDES ANY AREAS OFF-PROPERTY AND
OR OTHERWISE NOT INDICATED ON PLANS.
5. CONTRACTOR SHALL MAINTAIN POSITIVE DRAINAGE IN LAWN
AND PLANTING BED AREAS.
6. MULCH PLANTING BEDS WITH 3"AA HARDWOOD MULCH.
7. TREES TO HAVE FULL HEAD AND TO BE APPROVED BY
LANDSCAPE DESIGNER.
ALL IDEAS, DESIGNS, ARRANGEMENTS AND PLANS INDICATED OR
REPRESENTED BY THIS DRAWING ARE OWNED BY AND THE
PROPERTY OF VIVE EXTERIOR DESIGN, LLC AND WERE CREATED,
EVOLVED, AND DEVELOPED FOR THE USE ON AND IN
CONNECTION WITH THE SPECIFIED PROJECT. NONE OF THE
IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BY OR
DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF
VIVE EXTERIOR DESIGN, LLC.
WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE
PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL
VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND
CONDITIONS ON THE JOB. THE DESIGNER MUST BE NOTIFIED OF
ANY VARIATION FROM THE DIMENSIONS AND CONDITIONS
SHOWN BY THESE DRAWINGS.
WARNING:
REPRODUCTION OF THESE PLANS IS A CRIMINAL OFFENSE UNDER
18 U.S.C. SEC. 506. UNAUTHORIZED DISCLOSURE MAY
CONSTITUTE TRADE SECRET MISAPPROPRIATION IN VIOLATION
OF I.C. 24-2-31-1 ET. SEQ. AND OTHER LAWS. THE IDEAS,
ARRANGEMENTS AND DESIGNS DISCLOSED HEREIN MAY BE
PATENTED OR BE THE SUBJECT OF PENDING PATENT
APPLICATION.
COPYRIGHT VIVE EXTERIOR DESIGN.
MASTER PLAN FOR:
LEISHMANS RESIDENCE
12157 Heather Stone Place
Carmel, IN 46032
11071 East 126th Street
Fishers, IN 46038
p: 317-773-9933
www.artisanoc.com
01/27/23