Loading...
HomeMy WebLinkAboutS900 - Second Floor Layout Start Spacing 19.2" O.C. Framing Connector Summary PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Backer Blks Filler Web Stiff H1 1 Simpson IUS1.81/14 Designed 12- 10dx1.5 - 2- 10dx1.5 - No No Yes H2 2 Simpson IUS1.81/14 Designed 12- 10dx1.5 - 2- Strong-Grip - 2 No No H3 5 Simpson IUS1.81/14 Designed 12- 10dx1.5 - 2- Strong-Grip - No No No H4 1 Simpson IUS2.37/14 Designed 12- 10d - 2- 10dx1.5 - No No Yes H5 8 Simpson IUS2.37/14 Designed 12- 10dx1.5 - 2- 10dx1.5 - No No Yes H6 3 Simpson IUS2.37/14 Designed 12- 10dx1.5 - 2- Strong-Grip - No No No H7 1 Simpson HHUS410 Designed 30- 10d - 10- 10d - No No No H8 1 Simpson IUS3.56/14 Designed 14- 10dx1.5 - 2- 10dx1.5 - No No Yes Products PlotID Length Product Plies Net Qty C38'-2 38' 0" 14" TJI 110 joist 2 2 C20'-2 20' 0" 14" TJI 110 joist 2 2 C20' 20' 0" 14" TJI 110 joist 1 2 C18' 18' 0" 14" TJI 110 joist 1 2 C16' 16' 0" 14" TJI 110 joist 1 6 C14' 14' 0" 14" TJI 110 joist 1 6 C4' 4' 0" 14" TJI 110 joist 1 5 CBk1 2' 0" 14" TJI 110 joist 1 4 S38'-2 38' 0" 14" TJI 360 joist 2 2 S38' 38' 0" 14" TJI 360 joist 1 12 S22' 22' 0" 14" TJI 360 joist 1 5 S18' 18' 0" 14" TJI 360 joist 1 1 BBO35 18' 0" 1 3/4" x 18" 2.0E Microllam LVL (WSO) 2 2 M1-2 22' 0" 1 3/4" x 14" 2.0E Microllam LVL (WSO) 2 2 M2 18' 0" 1 3/4" x 14" 2.0E Microllam LVL (WSO) 1 1 M3-2 8' 0" 1 3/4" x 14" 2.0E Microllam LVL (WSO) 2 2 M4 6' 0" 1 3/4" x 14" 2.0E Microllam LVL (WSO) 1 1 RM1 16' 0" 1 1/8" x 14" TJ Rim Board 1 8 Total Lengths Length Product 400' 0" 14" TJI 110 joist 660' 0" 14" TJI 360 joist 36' 0" 1 3/4" x 18" 2.0E Microllam LVL (WSO) 84' 0" 1 3/4" x 14" 2.0E Microllam LVL (WSO) 128' 0" 1 1/8" x 14" TJ Rim Board LEVEL NOTES Current Date: 12/1/2022 File Name: 2023-0071lh, drees indy, alv-40.jvl Level Name: 2nd-Floor Framing Building Code - Design Methodology: IBC 2018 Members with Design Overridden: TJ-Pro Rating (Weighted Average): 48 Minimum Level TJ - Pro Rating & Joist: TJ-Pro rating = 42, joist = C20'(i2808) Maximum Level TJ - Pro Rating & Joist: TJ-Pro rating = 63, joist = C20'-2(i2815) FLOOR Floor Container:FC11 Use/Occupancy:ResidentialLivingAreas Floor Area Loading is:40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load Maximum Allowed Deflection:L/480 Live Load & L/240 Total Load TJ-Pro Rating Information: Weighted Average:48 Directly Applied Ceiling:Gypsum 1/2" Decking Attachment:Glue and Nail Decking Material:23/32"x48"x96" Weyerhaeuser Edge Gold Panel (0/24) T&G SF Perpendicular Partition:No Strapping at max 8' o.c.:None Blocking at max 8' o.c.:No Poured Flooring:No CS CS B4 B1 A3 A3 A3 A3 A3 A3 A3 A3 H2 B1 BBO35 BBO59 M3-2 Dropped LVLS38'-2S38'C38'-2S38'S22'C20'RM1RM1RM1RM1RM1RM1 RM1 RM1 RM1 RM1 RM1 CBk1 RM1 RM1 C20'-2C20'C4'M4Shower Toilet Tub Toilet BBO61BBO62 M2M1-237' 8"30' 0 1/2"20' 7"3' 10 1/2"13' 2 1/2"1' 0"1' 0" 6' 4" 10' 5" 20' 9" Tub Toilet 10 3/16" 1' 7 3/16" 9 5/8"1' 7 3/16" 9 5/8" 1' 7 3/16" 9 5/8" 4' 9"2' 0"CS 10' 6" 13' 2 1/2" H8H2H3H7 H4H1H2BBO68BBO69CS S18'CBk1 C16'C16' S38'S38' C4' S22' C14' C18' H5 H6 H3 TJI 110 TJI 360 TJI 560 Joists by Series Mechanical Chase Kitchen Island Hatch Legend Architectural Drawings Prepared By:Structural Drawings Prepared By:Drees Homesthe Buchanan "U" - ALV-40RevByDateCommentsDrawn By:LHChecked By:Release Date:12/1/2022Job # 2023-0071LH Sheet 2 of 2 A complete Javelin ® framing plan requires the Trus Joist Installation Guide See the Trus Joist Installation Guide for Product Trademark Information SYMBOL LEGEND Bearing Length Requirements Point Load (Operator Added) Line Load (Operator Added) Area Load (Operator Added) Beam by Others Detail Callout Label (See Framer's Pocket Guide) Non-Load Bearing Wall Joist Under Wall Above BBO A10'UWALack of proper bracing during construction can result in serious accidents. Observe the following guidelines: WARNING NOTES: WARNING Joists are unstable until braced laterally Bracing Includes: Blocking Hangers Sheathing Rim Board Strut Lines Rim Joist DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. DO NOT walk on joists that are lying flat. DO NOT walk on joists until braced. INJURY MAY RESULT. Weyerhaeuser, Microllam, Parallam, TimberStrand, TJI, TJ, and Trus Joist are registered trademarks of Weyerhaeuser NR. ©2014 Weyerhaeuser NR Company. All rights reserved. 1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI ® joists must be completely installed and properly nailed. 2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also be accomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay. 3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist. Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker or one layer of unnailed sheathing. 5. Ends of cantilevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within 1/2" from true alignment. 4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system. Flat blocking panels between each joist. Nail to top plate with connections equivalent to floor panel schedule. Less than 5"E9 118" TJ ® Rim Board or 1 1 4" TimberStrand® LSL. Attach to joist with one 10d (0.131" x 3") nail at top and bottom flanges. Nail rim to blocking panel and blocking panel to plate with connections equivalent to floor panel schedule. TJI® Joist WARNING Joists are unstable until laterally braced Safety bracing required during installation 2'-0" Max 2"2x6(min) or 1-18" x 4-1/2" (min) TJ® rim board nailed to top plate w/8d (0.113" x 2-3/8") nails at 6" o/c at panel edges and in field. Block must be full length between joists and tight to each flange 24 16 span rated sheathing ( 716" min). Attach with 8d (0.113" x 2-38") nails at 6" o.c. along panel edges and field. Use pressure treated plywood for ground level cantilevers 1-18" TJ® rim board to match joist depth Lateral load transfer of detail = 220 PLF. Additional connections may be required to transfer loads from wall above Second Floor System Scale: 1/4" = 1'0"These placement plans have been developed for the specificationof products based on project information provided. This service is solelyintended for product application assurance; and, is not intended tocircumvent the need for a design professional as determined by thebuilding code. The designer of record and/or builder/framer is responsibleto assure these drawings are compatible with the overall project.01/27/23