Loading...
HomeMy WebLinkAbout06070096 Site Plan ~ The Sclme1der CorponUOD 8901 ou. A:Jenue Historlo Fort HarrIJon JodIaDapolIJ. indiana 411216-1037 317-828-7100 317-826-7200 PAX 1o&In_ Sum,ma LlmdJcopf Arobltec\1D't GIS 'US Geololl' Plan Prepared for: dge Custom Homes , 163, containing 15,832 s'r.:l:, In Ie of Westclay Ion , 10012 ument , 200500070088 , 3, Slide 1752 Twp, HomOton County 28, T18N, RJE is Brood Street (90' R/W) lei, IN 46032 ared Dote: 07/17/06 : By. J(J lunity Restrictions: Yard = 5' Yard = 25' (3' far garages from alleys) 'gate = 15' 9 = R2 : The garoge finished floor elevation ~. above the elevation at the center ive, per pion. ud In streets from trucks 9 lot to be cleaned at the ,I each day. I boles and sUt fence to be used , needed to keep mud off 01 is and out of slorm sewers. !rvlce laterals log at curb ore ped: Sanitary Sewer Subsurface Drain Valer of water tap to be filled with granular riol to within 10. op of curb. of woter top to be restored s' original condition prior to lructlon. uiar back fill suggested r drivewoy ot sanitary r lateral trench, water line :h and any other excavoled ,. (II situation occurs) lion of utilities on plat pian ~enerol locations per plan and Id be verified In the field. : (secondary oreos - Westcloy) height: 35' on lots 100' and larger lYe line) 30' 00 less than 100' Max. rage: 50% : (primary areas - Weslclay) height: 30' Build-up line: 2 es Max. coverage: 50X eievatioo shown is per plans i, not the os-built elevation. information for the elevation rence between the primary finished elevation to the top of basement and to the basement finished wos provided by the client. Plot PIon leqend I]2Q;Q] Prapo,ed Grade, 000.0 Existing Grades __ 000.0-- Contour Grode * Approx. lateral location - . - Sanitary Sewer Lines -" - Storm Sewer Lines - IJ - Water Service Lines - - - - - - - Sub-Surface Drain lines . Manhole (Sanitary or Slorm) . Beehive Inlet (Storm) III Curb Inlet (Storm) D End Sectioo (Storm) ... Fire Hjdrant - """ _ D" D _ Flow LIne of swole - - Building Une (BL / BSL) - - - - - - - Easement Line Note: Sanitary Sewer Top of Costing Information Upstream Manhole. TC= 903.30 Downstream Manhole, Te:: 901.50 per pian. Nole: Contractor to molntaln 0 10 foot separation belween the Sanitary Lateral'" Water Lateral. I. Dennis L. Grumpp, duly licensed Land Surveyor, Indiana # 50303. do hereby certify that In my opinion. If the finished grades are constructed as shown. the Surface Drainage on the subject lot, will be satisfactory for Residential Construction. ,,\\1\\1\11111111//1111///1. ($."~ L /> ~-r~ ~ ,S 'liP ~ ~~~ '.................'r't7.A ~ "'O\STEFf'~" ""'A~ ~c-..... ..,~~ No 0.... -......? i ~( 50303 )~i ~ .... STATE OF.... ~ ~ /.... .... ~ "'<~ ...IAtOI/>,\'\......I\SCl ~ o '" ,.' ,~:s:- ~ '''01 ........... \.'" ~ ~ "1/ SUO\\ ,,~ ~J,rj, 1\' ~~~ ~////I1I1'I/IIII\I\I\I\I\I' O'-lf-rl Nole: The basement elevation. depicted hereon. has been determined and based upon the pad grades and/or contours taken from the construction plans for this subdivision. Unless stated, no information about fluctuating water tables. soil conditions. or son types has been provided or stoted on said pions. It Is recommended that the basement finished floor elevations be at least lwo feet (2') above the normal pool eie",tion of any adjoining bodies of water. unless a study of facts reveals otherwise. If during the excavation process any ground water is witnessed. The Schneider Corporation should be notified immediately. The basement elevation should be raised two feet (2') above the ground water, and additional construction techniques should be incorporated to alleviate future problems. Note: Sump pump(s) to be placed by builder a, needed. !~~ , 0 . .:.. TYPICAl SWALE SECllOf1 Detail of Ground Water flow pattern. I I IUI I I \ I LOT# 163 PO# 00721073 VB06,0058203 ~ ~ =~= Note: Bunder to ensure positive drainage away fl structure(s). Note: I Builder is to grade side yard swele to grades shown on this plan. If builder is unable to achieve positive drainage away from proposed structure, the engineer sholl be contacted. builder is not to' deviate from grades shown on this plen without the consent of bath the The Schneider Corp. and Brenwick Dev. This plot plan was prepared based on information token from record plats. subdivision plans. record drawings and plans provided by client. It is the responsibHity of the contractor to verify site conditions prior to construction and notify The Schneider corp. and Brenwick Development of any discrepancies. ~ Assumed North Scale: 1" = 30' / Finished Floor Elevation Information Pad Grade = 904.5 per pian Pad Grade + 0.3' = Gorage m (904.B) Pad Grade + 1.0' = Residence FFE (905.B) Residential m - 9.0'! = Basement FFE (B96.B) , ,- . PLIASE NOlE mAT mE STRAIGHT UNE SLOPE OF mE DRI~WA y mOM mE GARAGE FlNISHEO flOOR ELEVATION TO mE TOP Of THE CURB AT mE CENlER OF mE DRI~WA Y EXCEEDS 5% AS PROPOSED. mls SLOPE IS BASEO ON mE REQUIRED MINIMUM GARAGE FINISHED flOOR ELEVATION ANO mE EXISTING TOP OF CURB ElIVATlON. This drawing is not intended to be represented as a retracement or original boundary survey, 0 route survey, or 0 Surveyor Location Report.