Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
C201 SITE PLAN
US 421 (MICHICAN ROAD)N85°28'09"E 387.12'S20°32'51"E 151 .67 ' S85°28'08"W 325.06'S04°31'52"E 33.57'S85°28'09"W 101.91'R=122.00'L=65.94'N00°23'46"E 115.74'REDD ROAD18'5'5'8'18'25'9.51'25'18'5'5' 21.41' 16'12.5'25' 107.51'25'25'25'32.27'30.8'56.91'56.91'9' 9'8'8'8'19.51'19.51'5'5'6' 6.25' 24.91' EX. 23.37' EX'. PROPOSED BUILDING 3-STORY 9,650 SF ± 15' SIDE BSL 15' SIDE BSL60' FRONT BSL30' FRONT BSL & GREENBELTDRIVETHRUONLYDO NOT ENTERSTOP DRIVETHRUONLYDRIVETHRUONLYREMOTE TELLER CANOPY ATM 120' MAX . FRONT SETBACK(MICH IGAN RD .)o o oo o oo o oo o oo o oo o oo o oo o oo o oo o oo o oo o oA1 A1 A A A B A B B C D D D D E E E E E E1 F1 F1 F1 F1 F1 F1 F1 F2 F2 F3 F3 F3 F3 F3 F3 F3 F4 G O O O O H H H H J J J K K K K K K L L L L L L L L L L M N N N N N P J J B B A L F1 F4 I G1 L2 SPACES @ 9' = 18'R3 'R3'R12'R 1 2 'R3'R1'R5 ' R 7 'R5'R5'R7'R10'R1 0 'R5'R3'R10'R 1 0 'R50'R50'R30'R 1 5 ' R3 'R3'R2' R2' R2' R2'R10'R3'R3'CONSTRUCTION LIMITS CONSTRUCTION LIMITS CONSTRUCTION LIMITS CONSTRUCTION LIMITS 23 SPACES @ 9' = 207 ' 12 SPACES @ 9' = 108 '6 SPACES @ 9' = 54'R30'R30' 67.69' 209.16' 321.38' E K PROJECT NO. CHECK:DRAWN: PLAN DATE: DESIGN: STATE OF No. PE10707583 OO14020 Mississinewa Drive Carmel, Indiana 46033 P: 317.324.8695 F: 317.324.8717 www.Fritz-Eng.com Fritz Engineering Services, LLC REVISIONS AND ISSUES BYDATE CLIENT: PROJECT: PROJECT LOCATION: GENERAL NOTES / LEGEND: SECTION, TOWNSHIP, RANGE: SECURITY FEDERAL BANK CARMEL HOKANSON COMPANIES 10201 N. ILLINOIS ST. STE 400 CARMEL, IN 46290 12/21/2022 2211004 10880 N. MICHIGAN RD. CARMEL, INDIANA 46077 HAMILTON COUNTY NW 1 4, S6, T17N, R3E SHEET NAME SHEET NO. PRELI MI N A R Y NOT F O R CONS T R U C TI O N ©2023 FRITZ ENGINEERING SERVICES, LLC"IT'S THE LAW" R Know what's below. Call before you dig. 2 WORKING DAYS BEFORE YOU DIG. C201 SITE PLAN 1.REV PER CARMEL TAC 2/3/2023 AF AF AF KG 00 20'40' SCALE: 1" = 20' N PRINTED BY: Ashton FritzDATE: 2/3/2023 10:22 AMSHEET SIZE, SCALE: ANSI FULL BLEED D (34.00 X 22.00 INCHES), 1:1FILE NAME: F:\2022\2211004 - SECURITY FEDERAL BANK CARMEL\02 CIVIL\PLANS\C201.DWG, LAYOUT: C201KEY NOTES: A1 RIGHT OF WAY PAVEMENT (PER CARMEL DETAIL 10-22) A LIGHT DUTY ASPHALT PAVEMENT B HEAVY DUTY ASPHALT PAVEMENT C CONCRETE PAVEMENT, TYPE 2 D COMBINED CONCRETE CURB & WALK E CONCRETE WALK E1 CONCRETE WALK-RAMP F1 6" CONCRETE CURB F2 VALLEY CURB & GUTTER F3 CHAIRBACK CURB & GUTTER F4 6" CONCRETE CURB WITH CONCRETE ISLAND G ADA RAMP (PER INDOT DETAIL) G1 ADA PARKING SIGN (PER DETAIL, VAN PLAQUE WHERE NOTED) H 4" WHITE PAVEMENT STRIPING, TYP. I ADA BLUE PAVEMENT STRIPING, TYP. J PAVEMENT MARKING (AS SHOWN) K MATCH EXISTING PAVEMENT, CURB, OR WALK L LANDSCAPE AREA M DUMPSTER ENCLOSURE (REF. ARCH. PLAN) N EXISTING SIDEWALK/PAVEMENT TO REMAIN O SIDEWALK TRANSITION AT DRIVE (PER INDOT DETAIL) P BICYCLE PARKING (U-SHAPED, BLACK THERMOPLASTIC POWDER COATED) R SITE LIGHT POLE (REF. SITE LIGHTING PLAN) S MONUMENT SIGN NOTES: XX CARMEL ENGINEERING DEPARTMENT NOTE ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY. DRIVEWAY ENTRANCE SAW CUT NOTE DRIVEWAY ENTRANCE OFF OF REDD RD. WILL REQUIRE SAW CUTS PER CITY OF CARMEL STANDARDS. ALL CURB CUTS MUST BE SAW CUT TO THE NEAREST JOINT PAST THE REQUIRED LIMITS OF THE CURB REMOVAL. SIDEWALK NOTE ALL SIDEWALKS CONSTRUCTED WITHIN THE PUBLIC RIGHT-OF-WAY SHALL COMPLY WITH STANDARD CITY OF CARMEL AND/OR INDOT DETAILS. GENERAL NOTES: REFER TO ARCHITECTURAL & FOUNDATION PLANS FOR ALL BUILDING DIMENSIONS. BUILDING DIMENSIONS SHOWN HEREON ARE FOR REFERENCE ONLY. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT FROM THE CITY OF CARMEL. SITE DEVELOPMENT SUMMARY TABLE ZONING CLASSIFICATION, CITY OF CARMEL B-3, US 421 OVERLAY PARCEL SIZE 1.47 Ac. ± REQUIRED PROVIDED MIN. STREET FRONTAGE N/A MIN. LOT WIDTH 100 FT 151 FT MIN. LOT AREA 10,000 SF 64,000 SF ± MAX. BLDG HEIGHT 30' MAX.47.4' (VARIANCE REQ'D) MAX. LOT COVERAGE 80%61% BUILDING SETBACKS FRONT 60' - REDD ROAD 30' MICHIGAN ROAD, MAX. 120' 67.0 FT (ATM ACCESSORY STRUCTURE) 208.1 FT (DRIVE UP CANOPY) 314.9 FT (PRIMARY BUILDING) 30.8' (PRIMARY BUILDING) SIDE 15'19.5' REAR N/A N/A PARKING SETBACKS FRONT 30' - MICHIGAN ROAD 10' REDD ROAD > 30' MICHIGAN RD > 76' REDD RD SIDE 0'N/A REAR N/A N/A BUFFERYARDS / GREENBELTS FRONT 30' GREENBELT ALONG MICHIGAN ROAD 10' GREENBELT ALONG REDD RD. 30', MICHIGAN RD. 10', REDD RD. SIDE 5'5'-0" REAR N/A PARKING REQUIRED, SF 1 PS PER 250SF - GENERAL OFFICE PARKING REQUIRED 9,650 SF / 250 = 38.6 =39 TOTAL REQUIRED SPACES 43 STANDARD + 2 ADA SPACES 45 TOTAL SPACES BICYCLE PARKING REQUIRED 4 AT MULTI-TENANT BLDG MULTI-TENANT BUILDING - SITE - 4 (TWO INVERTED 'U' LOOPS) NOTE: 1.