Loading...
HomeMy WebLinkAboutCorrespondenceFrom:Littlejohn, David W To:Jim Walls Cc:Laurence G. Armstrong; Glaspie, Larysa E; Mestetsky, Henry; Fairman, Jenell; Hollibaugh, Mike P; Conn, Angelina V Subject:RE: Concourse - ADA parallel parking location Date:Friday, June 9, 2023 3:12:13 PM Thanks Jim, I think your proposal is the best way to address the accessibility issue I noted. Please include these walks in your next ProjectDox submittal and I will mark my comment as resolved. Please let me know if you have any questions or if you need anything else regarding this. Sincerely, David Littlejohn, AICP Transportation Systems Administrator/ADA Coordinator City of Carmel O: (317) 571-2306 M: (317) 750-2959 From: Jim Walls <jimw@pedcor.net> Sent: Friday, June 9, 2023 9:35 AM To: Littlejohn, David W <dlittlejohn@carmel.in.gov> Cc: Laurence G. Armstrong <laurence@pedcor.net>; Glaspie, Larysa E <lglaspie@carmel.in.gov>; Mestetsky, Henry <hmestetsky@carmel.in.gov>; Fairman, Jenell <jfairman@carmel.in.gov>; Hollibaugh, Mike P <MHollibaugh@carmel.in.gov>; Conn, Angelina V <Aconn@carmel.in.gov> Subject: Concourse - ADA parallel parking location David, We wanted to follow up on the added question in the last cycle for the Concourse project. That is the ADA connection at the monon trail to the ADA parking stall. Laurence and I looked over ADA stalls along the monon in Midtown. It appears that the only issue one (with wheelchair for instance) would have is traveling a distance on the cycle path in either direction. At all locations, a short walk connects the ADA pathway from the public way by crossing the cycle path to the parking stall. There are a couple spaces have this connection walk in line with the diagonal curbcut at the ADA stall. One other location requires the disabled to use the cycle path. This is the Concourse ADA parking stall location. See the attached PDF for conversation. Let us know more about what you are thinking. Markup C201 SITE LAYOUT PLAN.pdf ADA connection from parking to sidewalk Provide an accessible route from the ADA parking space to the sidewalk so that a person using the access ramp is not required to travel in the cycle track to access the sidewalk. This can be done in a similar that has been done at other ADA parking locations along the Monon Blvd. Thank you, Jim Walls, AIA, CSI, CDT Project Architect/Manager Pedcor Design Group 355 City Center Drive Carmel, IN 46032 317.705.7993 x7993 317.670.5711 cell Disclaimer: This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom theyare addressed. If you have received this email in error please notify the system manager. Please note that any views or opinions presented inthis email are solely those of the author and do not necessarily represent those of the company. If you are not the named addressee you shouldnot disseminate, distribute or copy this e-mail. Finally, the recipient should check this email and any attachments for the presences of viruses.The company accepts no liability for any damage caused by any virus transmitted by this email. Shestak, Joe From:Conn, Angelina V Sent:Monday, March 13, 2023 4:03 PM To:Lopez, Alexia K; Warner, Caleb; 'Greg Ilko'; Hollibaugh, Mike P; Jordan, Alex; Kass, Joslyn; Keeling, Adrienne M; Littlejohn, David W; Martin, Candy; Mindham, Daren; Mishler, Nicholas F; Motz, Lisa; Thomas, John G; Krueskamp, Theresa A; McCoy, David W; Willie Hall; 'maggie.crediford@trico.eco'; Shestak, Joe; 'ryan.hartman@trico.eco'; Jesse, Christina; Oberlander, Jon A; Prader, Kelli; Grechukhin, Sergey; Shalit, Aliza; Liggett, Brent E; Johnson, Angela; Hohlt, William G; Renick, Timothy; Rinehart, Morgan; Kashman, Jeremy M; Lynch-Mcgrath, Allison N; Speth, Nichole M; Worrell, Jeff Cc:Jim Walls; Fairman, Jenell; Lee, Mike E; Steve Sturtz; Laurence G. Armstrong; Glaspie, Larysa E; Mestetsky, Henry Subject:RE: Docket No. Assignment: The Concourse Mixed-Use Development (# PZ-2023-00027 DP/ADLS) Good afternoon, Everyone – The Petitioner would like to table this public hearing to May. We will send out a revised ‘docket no. assignment’ email once we finalize a new Plan Commission Hearing Officer meeting date. Sincerely, Angie Conn, AICP | Planning Administrator City of Carmel Planning & Zoning Dept. 1 Civic Square, 3rd Flr., Carmel, IN 46032 O: 317-571-2417 | W: carmeldocs.com From: Conn, Angelina V Sent: Thursday, March 9, 2023 10:42 AM To: Lopez, Alexia K <alopez@carmel.in.gov>; Warner, Caleb <cwarner@carmel.in.gov>; 'Greg Ilko' <gilko@crossroadengineers.com>; Hollibaugh, Mike P <MHollibaugh@carmel.in.gov>; Jordan, Alex <ajordan@carmel.in.gov>; Kass, Joslyn <jkass@carmel.in.gov>; Keeling, Adrienne M <AKeeling@carmel.in.gov>; Littlejohn, David W <dlittlejohn@carmel.in.gov>; Martin, Candy <cmartin@carmel.in.gov>; Mindham, Daren <dmindham@carmel.in.gov>; Mishler, Nicholas F <nmishler@carmel.in.gov>; Motz, Lisa <lmotz@carmel.in.gov>; Thomas, John G <jthomas@carmel.in.gov>; Krueskamp, Theresa A <TKrueskamp@carmel.in.gov>; McCoy, David W <DMcCoy@carmel.in.gov>; 'Willie Hall' <whall@crossroadengineers.com>; 'maggie.crediford@trico.eco' <maggie.crediford@trico.eco>; Shestak, Joe <jshestak@carmel.in.gov>; 'ryan.hartman@trico.eco' <ryan.hartman@trico.eco>; Jesse, Christina <cjesse@carmel.in.gov>; Oberlander, Jon A <joberlander@carmel.in.gov>; Prader, Kelli <kprader@carmel.in.gov>; Grechukhin, Sergey <sgrechukhin@carmel.in.gov>; Shalit, Aliza <ashalit@carmel.in.gov>; Liggett, Brent E <bliggett@carmel.in.gov>; Johnson, Angela <ajohnson@carmel.in.gov>; Hohlt, William G <WHohlt@carmel.in.gov>; Renick, Timothy <trenick@carmel.in.gov>; Rinehart, Morgan <mrinehart@carmel.in.gov>; Kashman, Jeremy M <jkashman@carmel.in.gov>; Lynch-Mcgrath, Allison N <alynchmcgrath@carmel.in.gov>; Speth, Nichole M <nspeth@carmel.in.gov>; Worrell, Jeff <jworrell@carmel.in.gov> Cc: Jim Walls <jimw@pedcor.net>; Fairman, Jenell <jfairman@carmel.in.gov>; Lee, Mike E <mlee@carmel.in.gov>; Steve Sturtz <steves@pedcor.net>; Laurence G. Armstrong <laurence@pedcor.net>; Glaspie, Larysa E <lglaspie@carmel.in.gov>; Mestetsky, Henry <hmestetsky@carmel.in.gov> Subject: Docket No. Assignment: The Concourse Mixed-Use Development (# PZ-2023-00027 DP/ADLS) I have issued the Plan Commission Hearing Officer Docket Number. It is the following: Docket No. PZ-2023-00027 DP/ADLS: The Concourse Mixed-Use Development. 1 1 Carmel Public Parking Sign Design & Criteria Department of Community Services CarmelCITYOF 2 Blade Signs A Blade Sign is the primary sign type used for public parking identification. It is to be located above or near all garage entrances and must be visible from each approach to the garage. If the entrance to the garage is not visible from the roadway, additional wayfinding signage is required to direct patrons from the road to the garage. The exact measurements and color specifications can be found below and must be adhered to. APPROVED BY DATE PAGE 3 Field survey required prior to fabricaon. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: CA LEFT ELEVATION SCALE: 3/4”=1’ RIGHT ELEVATION SCALE: 3/4”=1’ STREET FACING ELEVATION SCALE: 3/4”=1’ WALL FACING ELEVATION SCALE: 3/4”=1’ Style and construction to match existing sign 24” S4 Fabricate and install (1) 2 sided face lit blade sign Main Cabinet - .080” aluminum cladding, .040” returns, & 2” retainer painted MP 413420 brushed aluminum Boarder: 1/2” Clear Acrylic Push-thrus w/ second surface diffuser vinylFace: .090” Aluminum Painted PMS 072C Blue match w/ routed text and boarder “P”: 1/2” push through clear acrylic “P” with second surface diffuser vinyl Bottom Arm - .080” aluminum cladding, routed for 1/2” arrow clear acrylic push-thru w/ second surface diffuser, Front elevation painted PMS 1245C Yellow, side and back elevations painted PMS 1245C Yellow, PMS 491C Red Mounting: Thru-bolt mounted flush via aluminum spacers painted MP 413420 brushed aluminumIllumination: AVL 6500 white LEDs SCALE: 1/16”=1’72 1/2"56"60"10 3/4"3 3/4"9 1/4”28 1/2”9 1/4”2"31 5/8”S4 Railyard Chris Young Carmel, IN 7-12-2021 rail_5-3119-A_v2 PUBLICPARKING PUBLICPARKING APPROVED BY DATE PAGE 3 Field survey required prior to fabricaon. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: CA LEFT ELEVATION SCALE: 3/4”=1’ RIGHT ELEVATION SCALE: 3/4”=1’ STREET FACING ELEVATION SCALE: 3/4”=1’ WALL FACING ELEVATION SCALE: 3/4”=1’ Style and construction to match existing sign 24” S4 Fabricate and install (1) 2 sided face lit blade sign Main Cabinet - .080” aluminum cladding, .040” returns, & 2” retainer painted MP 413420 brushed aluminum Boarder: 1/2” Clear Acrylic Push-thrus w/ second surface diffuser vinylFace: .090” Aluminum Painted PMS 072C Blue match w/ routed text and boarder “P”: 1/2” push through clear acrylic “P” with second surface diffuser vinyl Bottom Arm - .080” aluminum cladding, routed for 1/2” arrow clear acrylic push-thru w/ second surface diffuser, Front elevation painted PMS 1245C Yellow, side and back elevations painted PMS 1245C Yellow, PMS 491C Red Mounting: Thru-bolt mounted flush via aluminum spacers painted MP 413420 brushed aluminumIllumination: AVL 6500 white LEDs SCALE: 1/16”=1’72 1/2"56"60"10 3/4"3 3/4"9 1/4”28 1/2”9 1/4”2"31 5/8”S4 Railyard Chris Young Carmel, IN 7-12-2021 rail_5-3119-A_v2 PUBLICPARKING PUBLICPARKING APPROVED BY DATE PAGE 3 Field survey required prior to fabricaon. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: CA LEFT ELEVATION SCALE: 3/4”=1’ RIGHT ELEVATION SCALE: 3/4”=1’ STREET FACING ELEVATION SCALE: 3/4”=1’ WALL FACING ELEVATION SCALE: 3/4”=1’ Style and construction to match existing sign 24” S4 Fabricate and install (1) 2 sided face lit blade sign Main Cabinet - .080” aluminum cladding, .040” returns, & 2” retainer painted MP 413420 brushed aluminum Boarder: 1/2” Clear Acrylic Push-thrus w/ second surface diffuser vinylFace: .090” Aluminum Painted PMS 072C Blue match w/ routed text and boarder “P”: 1/2” push through clear acrylic “P” with second surface diffuser vinyl Bottom Arm - .080” aluminum cladding, routed for 1/2” arrow clear acrylic push-thru w/ second surface diffuser, Front elevation painted PMS 1245C Yellow, side and back elevations painted PMS 1245C Yellow, PMS 491C Red Mounting: Thru-bolt mounted flush via aluminum spacers painted MP 413420 brushed aluminumIllumination: AVL 6500 white LEDs SCALE: 1/16”=1’72 1/2"56"60"10 3/4"3 3/4"9 1/4”28 1/2”9 1/4”2"31 5/8”S4 Railyard Chris Young Carmel, IN 7-12-2021 rail_5-3119-A_v2 PUBLICPARKING PUBLICPARKING Created by "ISF Signs PMS 1245 (Mustard Yellow) PMS 431C (Brick Red) PMS 072C (Blue) 2 sided face-lit Blade Sign specs: Main Cabinet - .080" aluminum cladding, .040" returns, 2" retainer painted MP 413420 brushed aluminum. Boarder - ½" Clear Acrylic Push-thrus with second surface diffuser vinyl Face - .090" Aluminum Painted PMS 072C Blue match with routed text and boarder. "P" - ½" push-thru clear acrylic "P" with second surface diffuser vinyl. Bottom Arm - .080" aluminum cladding, routed for ½" arrow clear acrylic push-thru with second surface diffuser. Front elevation painted PMS 1245C Yellow, side and back elevations painted PMS 1245C Yellow, PMS 491C Red. Mounting - Thru-bold mounted flush via aluminum spacers painted MP 413420 brushed aluminum. Illumination - AVL 6500 white LEDs. Left Elevation Scale: ¾"=1' Right Elevation Scale: ¾"=1' APPROVED BY DATE PAGE 3 Field survey required prior to fabricaon. All electrical is configured to 120V unless otherwise specified. The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product. •DESIGN FABRICATION isfsigns.com317.251.1219 6468 Rucker Road •INSTALLATION SERVICE Indianapolis, IN 46220 DESIGNED BY: CA REVISED LAST BY: CA LEFT ELEVATION SCALE: 3/4”=1’ RIGHT ELEVATION SCALE: 3/4”=1’ STREET FACING ELEVATION SCALE: 3/4”=1’ WALL FACING ELEVATION SCALE: 3/4”=1’ Style and construction to match existing sign 24” S4 Fabricate and install (1) 2 sided face lit blade sign Main Cabinet - .080” aluminum cladding, .040” returns, & 2” retainer painted MP 413420 brushed aluminum Boarder: 1/2” Clear Acrylic Push-thrus w/ second surface diffuser vinylFace: .090” Aluminum Painted PMS 072C Blue match w/ routed text and boarder “P”: 1/2” push through clear acrylic “P” with second surface diffuser vinyl Bottom Arm - .080” aluminum cladding, routed for 1/2” arrow clear acrylic push-thru w/ second surface diffuser, Front elevation painted PMS 1245C Yellow, side and back elevations painted PMS 1245C Yellow, PMS 491C Red Mounting: Thru-bolt mounted flush via aluminum spacers painted MP 413420 brushed aluminumIllumination: AVL 6500 white LEDs SCALE: 1/16”=1’72 1/2"56"60"10 3/4"3 3/4"9 1/4”28 1/2”9 1/4”2"31 5/8”S4 Railyard Chris Young Carmel, IN 7-12-2021 rail_5-3119-A_v2 PUBLICPARKING PUBLICPARKING Wall Facing Elevation Scale: ¾"=1' Street Facing Elevation Scale: ¾"=1' 3 Wall Signs When room is available, a wall sign may be used in conjunction with a blade sign. Wall signs must include the development’s name, “Parking Garage,” and the standard public parking P, as defined on page 7, on both sides of the name. Doing so communicates to drivers that the garage is public and identifies the development they will be parking at. Wall signs are to be flush or pin mounted and the colors and illumination must fit within the context of the development and surrounding uses. Example: 4 Suspended & Vinyl Signs A suspended sign is meant for pedestrians and vehicular drivers as they approach a garage opening. Hanging from a canopy, it signals vehicles to slow down, as well as for pedestrians to watch for oncoming traffic. This sign type must include the garage name, the standard public parking P, and a directional arrow. A red stripe is present at the top of the sign. Vinyl signage may also be used on canopy faces or garage doors. This sign type is meant as a secondary sign when a Suspended Sign is unfeasible. This sign type must include the garage name, the standard public parking P, and any other instructional or wayfinding text. Carmel P (See specifications page)Background color to match canopyCopy is Arial Bold 65" 8 5" PMS 491C (Brick Red) PARKING GARAGE Canopy Face PARKING GARAGE Carmel P (See specifications page)Copy is Arial Bold 8" 5 Digital Signs Digital signs alert drivers as to exactly how many empty spaces are currently available. The City of Carmel has two different units currently in use. One shows how many total parking spaces are free, the other one shows spaces available per category: regular spaces, EV charging spaces, handicap, and in some cases dedicated spaces. For questions and coordination of digital signage, please contact the Carmel Redevelopment Commission (CRC) at (317) 819-7207. 6 Entrance & Directional Signs Standard Public Parking and Resident Parking Signs A “Public Parking” header is required above all public vehicle entrances of the parking garage. This header must be mounted on black metal backing to increase visibility and include “Public Parking” text, two standard public parking P’s, and the standard lane indicator symbols. A “Resident Parking Only” header may be used above private vehicle entrances of the parking garage. This header must be mounted on black metal backing to increase visibility and include “Resident Parking Only” text and the standard lane indicator symbols. 7 Specs Public Parking/Resident Parking Only Specifications: 3D Metal Text Font: Arial Bold White Type on Black Metal Backing 8"13" 13"8" 8½" 1¾" thick 9" 1¾" thick 8"6½" ¼" white border PMS 186C (Red) PMS 368C (Green) PMS 072C (Blue) "P" Font: Franklin Gothic Heavy White Type on Blue Background Red "X": 3D Metal Green Arrow: 3D Metal Note: The X is recommended to be .5" shorter than the arrow to match the illusion of size. Note: Entrance Arrow is purposely shorter arrow. PMS 13-0630TN (Yellow) Note: Pay attention to word tracking and spread layout for visual balance. Clearance Bar Font: Franklin Gothic Demi Black Type on Safety Yellow Plastic Hanging Bar 5"3" Lettering Main Cabinet Specs: .080” aluminum cladding, .040” 3” deep returns painted Black -“P” circles: NON-LIT 1/2” flat cut acrylic digitally printed / UV treated White / (PMS 072C) Oracal 651 printable vinyl on face only mounted flush to cabinet (non-lit P’s and the circles are not routed copy and are just printed/laminated vinyl on the routed flat circle face) - Faces routed for 1/2” clear acrylic push-thrus with 2nd surface diffuser vinyl - “X” has digitally printed / UV treated (PMS 186C) Oracal 651 printable vinyl on face only - Arrow has digitally printed / UV treated (PMS 368C) Oracal 651 printable vinyl on face only Backs: .063” aluminum Illumination: Sloan Prisms White LEDs Mounting: Thru-bolt mounted flush to brick fascia - depending on thickness of facade stud mounting may be required Small Public Parking P and Directional Symbol Specifications: Clearance Bar Specification: 8 Other Exterior Signs The City will allow signage for public parking to be installed on light poles or as stand alone off-premise signs. These options are available when locating a particular parking garage has proven difficult for drivers and additional direction is required. Under special circumstances the City will allow uniquely designed public parking signs. These sign types should blend with a building’s architecture or contain designs and images unique to the district or surrounding uses. Pedestrian-scale exterior signage is required on all exterior doors to the garage. This signage shall include the name and address of the parking garage as well as “Parking Garage” text. 9 Sign Specs White and black borders are both 1/2” 3'1'-5"7¼"7¼"2' Reflective White Paint Text, Arrow & Borders on dibond sign face. Sign face color should emulate the structure color it is installed on. PMS 072C (Blue) The City of Carmel public parking symbol is a PMS 072 C (Blue) circle with a Franklin Gothic Heavy P centered in the middle. A white ring is also included. If used for directing traffic a white arrow is included below. P is Franklin Gothic Heavy and centered on circle Sign panel color should emulate the structure color it is installed on PMS 072C (Blue) Smaller directional style signs require reflective white paint text, arrow, and borders. 10 Interior Signs In addition to exterior signs, the City requires interior signage. Specifically, bicycle parking, video surveillance, and “No loitering or skateboarding” signs are required. Additionally, interior wayfinding, directory, and reserved parking signs should be included. The City recommends a cohesive design throughout the garage. Final design is subject to approval by the Carmel Redevelopment Commission. Bike Parking Copy is Arial Bold PMS 072C (Blue) When bike parking is present, directional signage is required. The public bike parking sign is similar to the public parking signs, however, the copy Bike Parking and image of a bicycle is incorporated on the sign. Signs will be installed near entrances and any other locations to properly direct cyclists to the parking area. A vector image of the bicycle can be provided upon request. 24-Hour Video Surveillance signs are required when City cameras are installed in the garage. Signs are installed at the main entrances to the garage. Please direct questions to the Carmel Information and Communications Systems Department (317-571-2567). 11 Interior Signs 1.5" Radius 3/8" Holes NO LOITERING OR SKATEBOARDING PERMITTED Carmel City Code §§6-66; 6-73 18" 1.5" 1.5" Per Ordinances D-2534-20 and D-2484-19 , skateboarding and loitering are not permitted within public parking garages. Signage, matching the adjacent specifications, is required to be installed in all public parking garages. Privately owned public parking garages are not automatically covered by the no loitering and no skateboarding ordinances. All privately owned public parking garages will need to enter into an Agreement for Parking and Traffic Regulation on Private Business Property with the City of Carmel to be protected by Carmel City Code § §6-66; 6-73, allowing police enforcement in the garage. Please work with the Carmel Redevelopment Commission to execute this agreement. 12 Please direct any questions to the City of Carmel Department of Community Services (317-571-2417) or Carmel Redevelopment Commission (317-819-7207) All Exterior Signs require Sign Permits through the Department of Community Services.