Thanks Jim, I think your proposal is the best way to address the accessibility issue I noted. Please include these walks in your next ProjectDox submittal and I will
mark my comment as resolved. Please let me know if you have any questions or if you need anything else regarding this.
Sincerely,
David Littlejohn, AICP
Transportation Systems Administrator/ADA Coordinator
City of Carmel
O: (317) 571-2306
M: (317) 750-2959
From: Jim Walls <jimw@pedcor.net>
Sent: Friday, June 9, 2023 9:35 AM
To: Littlejohn, David W <dlittlejohn@carmel.in.gov>
Cc: Laurence G. Armstrong <laurence@pedcor.net>; Glaspie, Larysa E <lglaspie@carmel.in.gov>; Mestetsky, Henry <hmestetsky@carmel.in.gov>; Fairman, Jenell
<jfairman@carmel.in.gov>; Hollibaugh, Mike P <MHollibaugh@carmel.in.gov>; Conn, Angelina V <Aconn@carmel.in.gov>
Subject: Concourse - ADA parallel parking location
David,
We wanted to follow up on the added question in the last cycle for the Concourse project. That is the ADA connection at the monon trail to the ADA parking stall.
Laurence and I looked over ADA stalls along the monon in Midtown. It appears that the only issue one (with wheelchair for instance) would have is traveling a
distance on the cycle path in either direction. At all locations, a short walk connects the ADA pathway from the public way by crossing the cycle path to the parking
stall. There are a couple spaces have this connection walk in line with the diagonal curbcut at the ADA stall. One other location requires the disabled to use the
cycle path.
This is the Concourse ADA parking stall location. See the attached PDF for conversation. Let us know more about what you are thinking.
Markup
C201 SITE LAYOUT PLAN.pdf
ADA connection from parking to sidewalk
Provide an accessible route from the ADA parking space to the sidewalk so that a person using the access ramp is not required to travel in the cycle track to access the sidewalk. This can be done in a
similar that has been done at other ADA parking locations along the Monon Blvd.
Thank you,
Jim Walls, AIA, CSI, CDT
Project Architect/Manager
Pedcor Design Group
355 City Center Drive
Carmel, IN 46032
317.705.7993 x7993
317.670.5711 cell
Disclaimer: This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom theyare addressed. If you have received this email in error please notify the system manager. Please note that any views or opinions presented inthis email are solely those of the author and do not necessarily represent those of the company. If you are not the named addressee you shouldnot disseminate, distribute or copy this e-mail. Finally, the recipient should check this email and any attachments for the presences of viruses.The company accepts no liability for any damage caused by any virus transmitted by this email.
Shestak, Joe
From:Conn, Angelina V
Sent:Monday, March 13, 2023 4:03 PM
To:Lopez, Alexia K; Warner, Caleb; 'Greg Ilko'; Hollibaugh, Mike P; Jordan, Alex; Kass,
Joslyn; Keeling, Adrienne M; Littlejohn, David W; Martin, Candy; Mindham, Daren;
Mishler, Nicholas F; Motz, Lisa; Thomas, John G; Krueskamp, Theresa A; McCoy, David
W; Willie Hall; 'maggie.crediford@trico.eco'; Shestak, Joe; 'ryan.hartman@trico.eco';
Jesse, Christina; Oberlander, Jon A; Prader, Kelli; Grechukhin, Sergey; Shalit, Aliza;
Liggett, Brent E; Johnson, Angela; Hohlt, William G; Renick, Timothy; Rinehart, Morgan;
Kashman, Jeremy M; Lynch-Mcgrath, Allison N; Speth, Nichole M; Worrell, Jeff
Cc:Jim Walls; Fairman, Jenell; Lee, Mike E; Steve Sturtz; Laurence G. Armstrong; Glaspie,
Larysa E; Mestetsky, Henry
Subject:RE: Docket No. Assignment: The Concourse Mixed-Use Development (#
PZ-2023-00027 DP/ADLS)
Good afternoon, Everyone – The Petitioner would like to table this public hearing to May. We will send out a revised
‘docket no. assignment’ email once we finalize a new Plan Commission Hearing Officer meeting date.
Sincerely,
Angie Conn, AICP | Planning Administrator
City of Carmel Planning & Zoning Dept.
1 Civic Square, 3rd Flr., Carmel, IN 46032
O: 317-571-2417 | W: carmeldocs.com
From: Conn, Angelina V
Sent: Thursday, March 9, 2023 10:42 AM
To: Lopez, Alexia K <alopez@carmel.in.gov>; Warner, Caleb <cwarner@carmel.in.gov>; 'Greg Ilko'
<gilko@crossroadengineers.com>; Hollibaugh, Mike P <MHollibaugh@carmel.in.gov>; Jordan, Alex
<ajordan@carmel.in.gov>; Kass, Joslyn <jkass@carmel.in.gov>; Keeling, Adrienne M <AKeeling@carmel.in.gov>;
Littlejohn, David W <dlittlejohn@carmel.in.gov>; Martin, Candy <cmartin@carmel.in.gov>; Mindham, Daren
<dmindham@carmel.in.gov>; Mishler, Nicholas F <nmishler@carmel.in.gov>; Motz, Lisa <lmotz@carmel.in.gov>;
Thomas, John G <jthomas@carmel.in.gov>; Krueskamp, Theresa A <TKrueskamp@carmel.in.gov>; McCoy, David W
<DMcCoy@carmel.in.gov>; 'Willie Hall' <whall@crossroadengineers.com>; 'maggie.crediford@trico.eco'
<maggie.crediford@trico.eco>; Shestak, Joe <jshestak@carmel.in.gov>; 'ryan.hartman@trico.eco'
<ryan.hartman@trico.eco>; Jesse, Christina <cjesse@carmel.in.gov>; Oberlander, Jon A <joberlander@carmel.in.gov>;
Prader, Kelli <kprader@carmel.in.gov>; Grechukhin, Sergey <sgrechukhin@carmel.in.gov>; Shalit, Aliza
<ashalit@carmel.in.gov>; Liggett, Brent E <bliggett@carmel.in.gov>; Johnson, Angela <ajohnson@carmel.in.gov>; Hohlt,
William G <WHohlt@carmel.in.gov>; Renick, Timothy <trenick@carmel.in.gov>; Rinehart, Morgan
<mrinehart@carmel.in.gov>; Kashman, Jeremy M <jkashman@carmel.in.gov>; Lynch-Mcgrath, Allison N
<alynchmcgrath@carmel.in.gov>; Speth, Nichole M <nspeth@carmel.in.gov>; Worrell, Jeff <jworrell@carmel.in.gov>
Cc: Jim Walls <jimw@pedcor.net>; Fairman, Jenell <jfairman@carmel.in.gov>; Lee, Mike E <mlee@carmel.in.gov>; Steve
Sturtz <steves@pedcor.net>; Laurence G. Armstrong <laurence@pedcor.net>; Glaspie, Larysa E
<lglaspie@carmel.in.gov>; Mestetsky, Henry <hmestetsky@carmel.in.gov>
Subject: Docket No. Assignment: The Concourse Mixed-Use Development (# PZ-2023-00027 DP/ADLS)
I have issued the Plan Commission Hearing Officer Docket Number. It is the following:
Docket No. PZ-2023-00027 DP/ADLS: The Concourse Mixed-Use Development.
1
1
Carmel
Public Parking Sign Design & Criteria
Department of Community Services
CarmelCITYOF
2
Blade Signs
A Blade Sign is the primary sign type used for public parking identification. It is to be located above or near
all garage entrances and must be visible from each approach to the garage. If the entrance to the garage is
not visible from the roadway, additional wayfinding signage is required to direct patrons from the road to the
garage. The exact measurements and color specifications can be found below and must be adhered to.
APPROVED BY
DATE
PAGE 3
Field survey required prior
to fabricaon.
All electrical is configured
to 120V unless otherwise
specified.
The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product.
•DESIGN FABRICATION
isfsigns.com317.251.1219
6468 Rucker Road
•INSTALLATION SERVICE
Indianapolis, IN 46220
DESIGNED BY: CA
REVISED LAST BY: CA
LEFT ELEVATION
SCALE: 3/4”=1’
RIGHT ELEVATION
SCALE: 3/4”=1’
STREET FACING ELEVATION
SCALE: 3/4”=1’
WALL FACING ELEVATION
SCALE: 3/4”=1’
Style and construction
to match existing sign
24”
S4
Fabricate and install (1) 2 sided face lit blade sign
Main Cabinet - .080” aluminum cladding,
.040” returns, & 2” retainer painted
MP 413420 brushed aluminum
Boarder: 1/2” Clear Acrylic Push-thrus w/ second
surface diffuser vinylFace: .090” Aluminum Painted PMS 072C Blue match
w/ routed text and boarder
“P”: 1/2” push through clear acrylic “P” with
second surface diffuser vinyl
Bottom Arm - .080” aluminum cladding,
routed for 1/2” arrow clear acrylic push-thru
w/ second surface diffuser,
Front elevation painted PMS 1245C Yellow, side and back
elevations painted PMS 1245C Yellow, PMS 491C Red
Mounting: Thru-bolt mounted flush via aluminum spacers
painted MP 413420 brushed aluminumIllumination: AVL 6500 white LEDs
SCALE: 1/16”=1’72 1/2"56"60"10 3/4"3 3/4"9 1/4”28 1/2”9 1/4”2"31 5/8”S4
Railyard
Chris Young
Carmel, IN
7-12-2021
rail_5-3119-A_v2
PUBLICPARKING PUBLICPARKING
APPROVED BY
DATE
PAGE 3
Field survey required prior
to fabricaon.
All electrical is configured
to 120V unless otherwise
specified.
The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product.
•DESIGN FABRICATION
isfsigns.com317.251.1219
6468 Rucker Road
•INSTALLATION SERVICE
Indianapolis, IN 46220
DESIGNED BY: CA
REVISED LAST BY: CA
LEFT ELEVATION
SCALE: 3/4”=1’
RIGHT ELEVATION
SCALE: 3/4”=1’
STREET FACING ELEVATION
SCALE: 3/4”=1’
WALL FACING ELEVATION
SCALE: 3/4”=1’
Style and construction
to match existing sign
24”
S4
Fabricate and install (1) 2 sided face lit blade sign
Main Cabinet - .080” aluminum cladding,
.040” returns, & 2” retainer painted
MP 413420 brushed aluminum
Boarder: 1/2” Clear Acrylic Push-thrus w/ second
surface diffuser vinylFace: .090” Aluminum Painted PMS 072C Blue match
w/ routed text and boarder
“P”: 1/2” push through clear acrylic “P” with
second surface diffuser vinyl
Bottom Arm - .080” aluminum cladding,
routed for 1/2” arrow clear acrylic push-thru
w/ second surface diffuser,
Front elevation painted PMS 1245C Yellow, side and back
elevations painted PMS 1245C Yellow, PMS 491C Red
Mounting: Thru-bolt mounted flush via aluminum spacers
painted MP 413420 brushed aluminumIllumination: AVL 6500 white LEDs
SCALE: 1/16”=1’72 1/2"56"60"10 3/4"3 3/4"9 1/4”28 1/2”9 1/4”2"31 5/8”S4
Railyard
Chris Young
Carmel, IN
7-12-2021
rail_5-3119-A_v2
PUBLICPARKING PUBLICPARKING
APPROVED BY
DATE
PAGE 3
Field survey required prior
to fabricaon.
All electrical is configured
to 120V unless otherwise
specified.
The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product.
•DESIGN FABRICATION
isfsigns.com317.251.1219
6468 Rucker Road
•INSTALLATION SERVICE
Indianapolis, IN 46220
DESIGNED BY: CA
REVISED LAST BY: CA
LEFT ELEVATION
SCALE: 3/4”=1’
RIGHT ELEVATION
SCALE: 3/4”=1’
STREET FACING ELEVATION
SCALE: 3/4”=1’
WALL FACING ELEVATION
SCALE: 3/4”=1’
Style and construction
to match existing sign
24”
S4
Fabricate and install (1) 2 sided face lit blade sign
Main Cabinet - .080” aluminum cladding,
.040” returns, & 2” retainer painted
MP 413420 brushed aluminum
Boarder: 1/2” Clear Acrylic Push-thrus w/ second
surface diffuser vinylFace: .090” Aluminum Painted PMS 072C Blue match
w/ routed text and boarder
“P”: 1/2” push through clear acrylic “P” with
second surface diffuser vinyl
Bottom Arm - .080” aluminum cladding,
routed for 1/2” arrow clear acrylic push-thru
w/ second surface diffuser,
Front elevation painted PMS 1245C Yellow, side and back
elevations painted PMS 1245C Yellow, PMS 491C Red
Mounting: Thru-bolt mounted flush via aluminum spacers
painted MP 413420 brushed aluminumIllumination: AVL 6500 white LEDs
SCALE: 1/16”=1’72 1/2"56"60"10 3/4"3 3/4"9 1/4”28 1/2”9 1/4”2"31 5/8”S4
Railyard
Chris Young
Carmel, IN
7-12-2021
rail_5-3119-A_v2
PUBLICPARKING PUBLICPARKING
Created by
"ISF Signs
PMS 1245
(Mustard Yellow)
PMS 431C
(Brick Red)
PMS 072C
(Blue)
2 sided face-lit Blade Sign specs:
Main Cabinet - .080" aluminum cladding,
.040" returns, 2" retainer painted MP
413420 brushed aluminum.
Boarder - ½" Clear Acrylic Push-thrus
with second surface diffuser vinyl
Face - .090" Aluminum Painted PMS
072C Blue match with routed text and
boarder.
"P" - ½" push-thru clear acrylic "P"
with second surface diffuser vinyl.
Bottom Arm - .080" aluminum cladding,
routed for ½" arrow clear acrylic
push-thru with second surface diffuser.
Front elevation painted PMS 1245C
Yellow, side and back elevations painted
PMS 1245C Yellow, PMS 491C Red.
Mounting - Thru-bold mounted flush
via aluminum spacers painted MP
413420 brushed aluminum.
Illumination - AVL 6500 white LEDs.
Left Elevation
Scale: ¾"=1'
Right Elevation
Scale: ¾"=1'
APPROVED BY
DATE
PAGE 3
Field survey required prior
to fabricaon.
All electrical is configured
to 120V unless otherwise
specified.
The concepts herein are the property of ISF INC. Permission to reproduce, copy or use the design or proposal can only be obtained through written agreement with ISF INC. Due to screen calibration and printing capabilities, the colors shown are only to be used as a close representation or final product.
•DESIGN FABRICATION
isfsigns.com317.251.1219
6468 Rucker Road
•INSTALLATION SERVICE
Indianapolis, IN 46220
DESIGNED BY: CA
REVISED LAST BY: CA
LEFT ELEVATION
SCALE: 3/4”=1’
RIGHT ELEVATION
SCALE: 3/4”=1’
STREET FACING ELEVATION
SCALE: 3/4”=1’
WALL FACING ELEVATION
SCALE: 3/4”=1’
Style and construction
to match existing sign
24”
S4
Fabricate and install (1) 2 sided face lit blade sign
Main Cabinet - .080” aluminum cladding,
.040” returns, & 2” retainer painted
MP 413420 brushed aluminum
Boarder: 1/2” Clear Acrylic Push-thrus w/ second
surface diffuser vinylFace: .090” Aluminum Painted PMS 072C Blue match
w/ routed text and boarder
“P”: 1/2” push through clear acrylic “P” with
second surface diffuser vinyl
Bottom Arm - .080” aluminum cladding,
routed for 1/2” arrow clear acrylic push-thru
w/ second surface diffuser,
Front elevation painted PMS 1245C Yellow, side and back
elevations painted PMS 1245C Yellow, PMS 491C Red
Mounting: Thru-bolt mounted flush via aluminum spacers
painted MP 413420 brushed aluminumIllumination: AVL 6500 white LEDs
SCALE: 1/16”=1’72 1/2"56"60"10 3/4"3 3/4"9 1/4”28 1/2”9 1/4”2"31 5/8”S4
Railyard
Chris Young
Carmel, IN
7-12-2021
rail_5-3119-A_v2
PUBLICPARKING PUBLICPARKING
Wall Facing
Elevation
Scale: ¾"=1'
Street Facing
Elevation
Scale: ¾"=1'
3
Wall Signs
When room is available, a wall sign may be used in conjunction with a blade sign. Wall signs must include the
development’s name, “Parking Garage,” and the standard public parking P, as defined on page 7, on both sides
of the name. Doing so communicates to drivers that the garage is public and identifies the development they
will be parking at.
Wall signs are to be flush or pin mounted and the colors and illumination must fit within the context of the
development and surrounding uses.
Example:
4
Suspended & Vinyl Signs
A suspended sign is meant for pedestrians and vehicular drivers as they approach a garage opening.
Hanging from a canopy, it signals vehicles to slow down, as well as for pedestrians to watch for
oncoming traffic. This sign type must include the garage name, the standard public parking P,
and a directional arrow. A red stripe is present at the top of the sign.
Vinyl signage may also be used on canopy faces or garage doors. This sign type is meant as a secondary sign
when a Suspended Sign is unfeasible. This sign type must include the garage name, the standard public
parking P, and any other instructional or wayfinding text.
Carmel P (See specifications page)Background color to match canopyCopy is Arial Bold
65"
8 5"
PMS 491C (Brick Red)
PARKING GARAGE
Canopy Face
PARKING GARAGE
Carmel P (See specifications page)Copy is Arial Bold
8"
5
Digital Signs
Digital signs alert drivers as to exactly how many empty spaces are currently available. The City of Carmel has
two different units currently in use. One shows how many total parking spaces are free, the other one shows
spaces available per category: regular spaces, EV charging spaces, handicap, and in some cases dedicated spaces.
For questions and coordination of digital signage, please contact the Carmel Redevelopment Commission (CRC)
at (317) 819-7207.
6
Entrance &
Directional Signs
Standard Public Parking and Resident Parking Signs
A “Public Parking” header is required above all public vehicle entrances of the parking garage.
This header must be mounted on black metal backing to increase visibility and include
“Public Parking” text, two standard public parking P’s, and the standard lane indicator symbols.
A “Resident Parking Only” header may be used above private vehicle entrances of the parking garage.
This header must be mounted on black metal backing to increase visibility and include
“Resident Parking Only” text and the standard lane indicator symbols.
7
Specs
Public Parking/Resident Parking Only Specifications:
3D Metal Text Font: Arial Bold
White Type on Black Metal Backing
8"13"
13"8"
8½"
1¾" thick
9"
1¾" thick
8"6½"
¼" white border
PMS 186C
(Red)
PMS 368C
(Green)
PMS 072C
(Blue)
"P" Font: Franklin Gothic Heavy
White Type on Blue Background
Red "X": 3D Metal Green Arrow: 3D Metal
Note: The X is recommended to be .5" shorter
than the arrow to match the illusion of size.
Note: Entrance Arrow is purposely shorter arrow.
PMS 13-0630TN
(Yellow)
Note: Pay attention to word tracking
and spread layout for visual balance.
Clearance Bar Font: Franklin Gothic Demi
Black Type on Safety Yellow Plastic Hanging Bar
5"3" Lettering
Main Cabinet Specs:
.080” aluminum cladding, .040” 3” deep returns painted Black
-“P” circles: NON-LIT 1/2” flat cut acrylic digitally printed / UV treated White / (PMS 072C) Oracal 651 printable vinyl on face only
mounted flush to cabinet (non-lit P’s and the circles are not routed copy and are just printed/laminated vinyl on the routed flat circle face)
- Faces routed for 1/2” clear acrylic push-thrus with 2nd surface diffuser vinyl
- “X” has digitally printed / UV treated (PMS 186C) Oracal 651 printable vinyl on face only
- Arrow has digitally printed / UV treated (PMS 368C) Oracal 651 printable vinyl on face only
Backs: .063” aluminum
Illumination: Sloan Prisms White LEDs
Mounting: Thru-bolt mounted flush to brick fascia - depending on thickness of facade stud mounting may be required
Small Public Parking P and Directional Symbol Specifications:
Clearance Bar Specification:
8
Other Exterior Signs
The City will allow signage for public parking to be installed on light poles or as stand alone off-premise signs.
These options are available when locating a particular parking garage has proven difficult for drivers and
additional direction is required.
Under special circumstances the
City will allow uniquely designed
public parking signs. These
sign types should blend with a
building’s architecture or contain
designs and images unique to the
district or surrounding uses.
Pedestrian-scale exterior
signage is required on
all exterior doors to the
garage. This signage
shall include the name
and address of the
parking garage as well
as “Parking Garage” text.
9
Sign Specs
White and black borders
are both 1/2”
3'1'-5"7¼"7¼"2'
Reflective White Paint
Text, Arrow & Borders
on dibond sign face.
Sign face color should
emulate the structure
color it is installed on.
PMS 072C
(Blue)
The City of Carmel public parking symbol is a PMS 072 C
(Blue) circle with a Franklin Gothic Heavy P centered in
the middle. A white ring is also included. If used for
directing traffic a white arrow is included below.
P is Franklin Gothic Heavy
and centered on circle
Sign panel color should
emulate the structure
color it is installed on
PMS 072C
(Blue)
Smaller directional style signs require reflective
white paint text, arrow, and borders.
10
Interior Signs
In addition to exterior signs, the City requires interior signage. Specifically, bicycle parking,
video surveillance, and “No loitering or skateboarding” signs are required.
Additionally, interior wayfinding, directory, and reserved parking signs should be included.
The City recommends a cohesive design throughout the garage. Final design is subject to approval
by the Carmel Redevelopment Commission.
Bike Parking Copy is Arial Bold
PMS 072C
(Blue)
When bike parking is present, directional signage is required.
The public bike parking sign is similar to the public parking
signs, however, the copy Bike Parking and image of a bicycle is
incorporated on the sign. Signs will be installed near entrances and
any other locations to properly direct cyclists to the parking area.
A vector image of the bicycle can be provided upon request.
24-Hour Video Surveillance signs are required when City
cameras are installed in the garage. Signs are installed at
the main entrances to the garage.
Please direct questions to the Carmel Information and
Communications Systems Department (317-571-2567).
11
Interior Signs
1.5" Radius
3/8" Holes
NO
LOITERING
OR
SKATEBOARDING
PERMITTED
Carmel City Code §§6-66; 6-73
18"
1.5"
1.5"
Per Ordinances D-2534-20 and D-2484-19 , skateboarding and loitering are not permitted within public parking
garages. Signage, matching the adjacent specifications, is required to be installed in all public parking garages.
Privately owned public parking garages are not automatically covered by the no loitering and no
skateboarding ordinances. All privately owned public parking garages will need to enter into an Agreement
for Parking and Traffic Regulation on Private Business Property with the City of Carmel to be protected by
Carmel City Code § §6-66; 6-73, allowing police enforcement in the garage. Please work with the Carmel
Redevelopment Commission to execute this agreement.
12
Please direct any questions to the City of Carmel
Department of Community Services (317-571-2417)
or Carmel Redevelopment Commission (317-819-7207)
All Exterior Signs require Sign Permits through the Department of Community Services.