Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A009 Rated Floor & Roof Types
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateTHE CONCOURSECarmel, IN 46032550 Monon BlvdPEDCOR DESIGN GROUP LLC Rated Floor & Roof Types THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2023 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 02/03/2023 A009 CITY REVIEW Revision ID Transmittal Set Date Transmittal Set Name 01 2/3/23 Carmel Review A B C D E 1 1 2 2 3 3 4 4 5 5 6 6 A B C D E NOT FORCONSTRUCTIONFriday, February 3, 2023, BIMcloud: pedcordesign - BIMcloud as a Service/Concourse/CONCOURSE9'-0" 9'-1 1/8" R-11 BATT INSULATION INSIDE FLOOR ASSEMBLY LIGHTWEIGHT TOPPING AND ACOUSTIC PAD FLOOR TRUSS 1 LAYER 5/8" GYP. BOARD ON RESILIENT CHANNELS CORRIDORSHAFT BEAM, REF. S- SERIES DRAWINGS FIRE SEALANT 2 LAYERS 5/8" GYPSUM WALL BOARD, CONTINUOUS AROUND BEAM R-21 HD BATT INSULATION BEAM, REF. S-SERIES DRAWINGS LIGHTWEIGHT TOPPING AND ACOUSTIC PAD FLOOR TRUSS 1 LAYER 5/8" GYP. BOARD ON RESILIENT CHANNELS SHAFTAPARTMENT FLOOR SHEATHING SHAFT LINER WALL SYSTEM 2 LAYERS 5/8" GYPSUM WALL BOARD, CONTINUOUS AROUND BEAM 1 LAYER 5/8" GYPSUM BD. ON RESILIENT CHANNELS, TYPE & SPACING PER UL LISTED ASSEMBLY FLOOR TRUSSES AND DECKING PER UL LISTED ASSEMBLY - SEE S-SERIES DRAWINGS LIGHTWEIGHT CONCRETE TOPPING & ACOUSTIC PAD WALL PLATE & CONNECTION, REF. S- SERIES DRAWINGS CORRIDOR APARTMENT FLOOR FINISHES & TRIM, REF. ROOM FINISH SCHEDULE & INTERIOR DETAILS R-11 BATT INSULATION INSIDE FLOOR ASSEMBLY, NO GAPS DRAFTSTOP SHEATHING CONTINUOUS 9'-0" 9'-1 1/8" 9'-0" 9'-1 1/8" 1 LAYER 5/8" GYPSUM BD. ON RESILIENT CHANNELS, TYPE & SPACING PER UL LISTED ASSEMBLY FIRE SEALANT AT HEAD OF WALL WOOD ROOF TRUSSES & DECKING PER UL LISTED ASSEMBLY, REF. S-SERIES DRAWINGS CONTINUOUS DRAFTSTOPPING SHEATHING FOR SHEAR PANELS, REF. S-SERIES DRAWINGS 5/8" GYPSUM BOARD, LISTED FOR RATED WALL R-19 BATT INSULATION (MINERAL WOOL WHEN BUILDING SEQUENCE REQUIRES INSULATION PRIOR TO WATER TIGHT CONDITIONS) 2X6 WOOD STUDS, MIN. 16" O.C. FOR FIRE RATING, REF. S-SERIES DRAWINGS FOR STRUCTURAL REQUIRED SPACING CORRIDOR APARTMENT PLYWOOD DRAFT STOP ABOVE EVERY DEMISING WALL TYP. R-11 BATT INSULATION FLOOR TRUSS, SEE S- SERIES DRAWINGS 2X4 WOOD STUD WALL, MIN. 16" O.C. FOR FIRE RATING, REF. S- SERIES DRAWINGS FOR STRUCTURAL REQUIREMENTS SHEATHING FOR SHEAR PANELS, REF. S-SERIES DRAWINGS 5/8" GYPSUM WALL BOARD, LISTED FOR RATED WALL 1 HOUR RATING WP 3370 9'-0" 9'-1 1/8" ROOF TRUSSES, REFERENCE S-SERIES FOR STRUCTURAL REQUIREMENTS. R-11 BATT INSULATION DRAFTSTOPPING ABOVE EVERY DEMISING WALL TYP. 2X WOOD BLOCKING, REF. S-SERIES DRAWINGS DRAFTSTOPPING, CONTINUOUS 2 A504 CONCRETE BUMPER WALL EIFS CLADDING EXPANSION JOINT FLASHING FLOOR TRUSSES AND DECKING PER UL LISTED ASSEMBLY - SEE S-SERIES DRAWINGS LIGHTWEIGHT CONCRETE TOPPING & ACOUSTIC PAD FLOOR FINISHES & TRIM, REF. ROOM FINISH SCHEDULE & INTERIOR DETAILS 1 LAYER 5/8" GYPSUM BD. ON RESILIENT CHANNELS, TYPE & SPACING PER UL LISTED ASSEMBLY CONTINUOUS BLOCKING BETWEEN TRUSSES FOR EXPANSION JOINT CONNECTION R-11 BATT INSULATION 2X4 WOOD STUD WALL, MIN. 16" O.C. FOR FIRE RATING, REF. S-SERIES DRAWINGS FOR STRUCTURAL REQUIREMENTS SHEATHING FOR SHEAR PANELS, REF. S-SERIES DRAWINGS POST-TENSIONED CONCRETE SLAB 2X6 WOOD STUD WALL, GYPSUM BOARD BOTH SIDES CONCRETE WALL FLOOR TRUSSES AND DECKING PER UL LISTED ASSEMBLY - SEE S-SERIES DRAWINGS LIGHTWEIGHT CONCRETE TOPPING & ACOUSTIC PAD FLOOR FINISHES & TRIM, REF. ROOM FINISH SCHEDULE & INTERIOR DETAILS 1 LAYER 5/8" GYPSUM BD. ON RESILIENT CHANNELS, TYPE & SPACING PER UL LISTED ASSEMBLY PLYWOOD SHEATHING 9'-0" 9'-1 1/8" R-21 HD BATT INSULATION ROOF TRUSS CORRIDORSHAFT SHAFT LINER WALL SYSTEM C-H STUD 2 LAYERS 5/8" GYPSUM WALL BOARD, CONTINUOUS AROUND BEAM 9'-0" 9'-1 1/8" BEAM, REF. S- SERIES DRAWINGS ROOF TRUSS SHAFTCORRIDOR 2 LAYERS 5/8" GYPSUM WALL BOARD, CONTINUOUS AROUND BEAM R-11 BATT INSULATION SHAFT LINER WALL SYSTEM SCALE: 1 1/2"= 1'-0" C5 Shaft Section Detail A009 0 6''12''18'' SCALE: 1 1/2"= 1'-0" C6 Shaft Section Detail A009 0 6''12''18'' SCALE: 1 1/2"= 1'-0" C1 Section Detail A009 0 6''12''18'' SCALE: 1 1/2"= 1'-0" B1 Section Detail A009 0 6''12''18'' SCALE: 1 1/2"= 1'-0" D1 Section Detail A009 0 6''12''18'' SCALE: 1 1/2"= 1'-0" D3 Demising Wall Section Detail A009 0 6''12''18'' SCALE: 1 1/2"= 1'-0" B3 Demising Wall Section Detail A009 0 6''12''18'' SCALE: 1 1/2"= 1'-0" C2 Section Detail A009 0 6''12''18'' SCALE: 1 1/2"= 1'-0" E3 Demising Wall Section Detail A009 0 6''12''18'' SCALE: 1 1/2"= 1'-0" E1 Section Detail A009 0 6''12''18'' SCALE: 1 1/2"= 1'-0" D2 Section Detail A009 0 6''12''18'' SCALE: 1 1/2"= 1'-0" B5 Shaft Section Detail A009 0 6''12''18'' SCALE: 1 1/2"= 1'-0" B6 Shaft Section Detail A009 0 6''12''18''