HomeMy WebLinkAboutA111A 1st RCPProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateTHE CONCOURSECarmel, IN 46032550 Monon BlvdPEDCOR DESIGN GROUP LLC 1st RCP THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2023 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 02/03/2023 A 111A CITY REVIEW Revision ID Transmittal Set Date Transmittal Set Name Change Name Change ID 01 2/3/23 Carmel Review Friday, February 3, 2023, BIMcloud: pedcordesign - BIMcloud as a Service/Concourse/CONCOURSENOT FORCONSTRUCTION13.913.9 13.813.8 K 1212 16 16 1717 L.1D.8CB0.8A NA.3 M 1414 15 15 1313 11 J.1D.3D.1A.1 L.5F 13.113.1 A G7.9 GJGA G8 G7.5 G7 GB GE G6.7 GIGGGCGHGA.9G.9A G7.6 GF 223'-5 33/64" 6'-6"6'-6"6'-6"6'-6"13'-0"6'-6"6'-6"3'-0 5/8"8'-0"8'-0"5'-0"6'-6"6'-6"6'-6"6'-0"6'-8 21/32"6'-9 41/64"6'-6" EQ.EQ. EQ.EQ.4'-0"8'-0"8'-0"11'-1" A.F.F. TOP RAMP 9'-6" 10'-7" 9'-0"9'-0" OPEN OPEN OPEN OPEN OPEN 11'-1" 12'-4" OPEN A1 A301 C1 A301 C1 A301 B1 A302 C1 A302 A1 A506 A2 A506 A3 A3 A506 A4 A506 A4 A506 A2 A506 #DrgID #LayID 1 1 1 1 1 1 1 1 2 2 10 16 16 16 1616 16 16 16 16 16 15 15CP18CP18 CP18 CP18 CP18 CP18CP18 CP18 CP18 CP18 CP18CP18 CP18 CP18CP18CP18CP18 CP18 CP18 SIM. SIM. OPP. SIM. OPP.4'-0 9/16"4'-0 9/16"REFLECTED CEILING PLAN NOTES CP1 PROVIDE 1/4" WALL AND CEILING CONTROL JOINTS - FRY REGLET DRM-50-25-2-PC OR EQUAL. REFER TO DETAILS XX/AXXX. CP2 FINISH FACE OF GYP. BD. BULKHEAD TO ALIGN WITH FINISH FACE OF ADJACENT WALL. CP3 SCONCE TO BE MOUNTED THE DIMENSION INDICATED FROM CENTER LINE OF ELEVATOR DOOR R.O. AND AT XX A.F.F. TO CENTER OF BACK PLATE. CP4 SUSPEND PENDANT AT 7'-6" A.F.F. TO THE BOTTOM OF FIXTURE. CP5 SCONCE TO BE MOUNTED AT 5'-6" A.F.F. AND 2'-5" FROM CENTER LINE OF DOOR R.O., UNLESS NOTED OTHERWISE. CP6 SCONCE TO BE MOUNTED THE DIMENSION INDICATED FROM CENTERLINE OF ELEVATOR DOOR R.O. AND AT 6'-0" A.F.F. TO CENTER OF BACK PLATE. CP7 SUSPEND PENDANT AT 6'-0" A.F.F TO BOTTOM OF FIXTURE. EQUALLY SPACE PENDANTS CENTERED ABOVE ISLAND KNEE WALL BELOW. CP8 PAINT SIDE AND BOTTOM OF DRYWALL BULKHEAD PX. REFER TO SHEET AXXX FOR SECTION DETAIL. CP9 SEE E SERIES FOR LIGHTING AND LOCATIONS. CP10 SEE E SERIES FOR LIGHTING AND LOCATION IN STAIR WELLS. CP11 PROVIDE 18"X18" ACCESS PANEL FOR WATER SHUT OFF VALVE AT THIS LOCATION. ACCESS PANEL TO BE 1 HOUR RATED ASSEMBLY WITH SECURITY LATCH. FRAME AND PANEL ARE TO BE CONCEALED FLANGE TYPE REQUIRING DRYWALL FINISHING AND CEILING FINISH. CP12 PROVIDE ACCESS PANEL FOR WATER SHUT OFF VALVE AT THIS LOCATION FOLLOWING WOOD PLANK MANUFACTURER'S INSTRUCTIONS. INCLUDE PIECES AND TRIM AS RECOMMENDED BY MANUFACTURER FOR PANEL ACCESS. CP13 PROVIDE WOOD PLANK CEILING BULKHEAD. REFER TO COMMON AREA FINISHES FOR WOOD PLANK SPECS. USE WOOD PLANK TRIM PIECE TO WRAP SIDES OF BULKHEAD. CP14 EXTERIOR GYP. SOFFIT CONTROL JOINT. CP15 EXTERIOR AWNING. CP16 EXTERIOR CANOPY CP17 2" LINEAR EXTERIOR SOFFIT VENT CP18 CONCRETE BEAM ABOVE. CP19 1' WIDE COVERAGE X 1" DEEP LINEAR METAL SOFFIT PANELS SYSTEM. GENERAL CEILING NOTES: 1. CEILING HEIGHT DESIGNATED BY BENCHMARK ABOVER FINISHED FLOOR (AFF). 2. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. 3. PROVIDE FIRE RATED DAMPERS REQUIRED AT FIRE RATED WALLS. 4. TRADES TO COORDINATE THE HEIGHT OF FIRE SUPPRESSION LINES, ROOF DRAIN LEADERS, ROOF STACK VENTS AND CONDENSATE LINES TO ALLOW FOR CEILING HEIGHTS AS INDICATED ON THE REFLECTED CEILING PLAN. 5. SEE RCP PLANS AND SCHEDULE FOR CEILING HEIGHTS. 6. SEE E SERIES SHEETS FOR ELECTRICAL AND DATA LOCATIONS. 7. GYPSUM BOARD FINISHING: A. COMPLY WITH ASTM C 840 STANDARD SPECIFICATION AND FINISHING OF GYPSUM BOARD; GA 214 RECOMMENDED LEVELS OF GYPSUM BOARD FINISH; AND GA 216-2000 APPLICATION AND FINISHING OF GYPSUM BOARD. B. PROVIDE GYPSUM BAORD MINIMUM FINISH LEVELS MEETING THE CRITERIA ESTABLISHED IN GA 214 AS FOLLOWS: 1. LEVEL 1 – GYPSUM WALL BOARD PERMANENTLY CONCEALED FROM VIEW. 2. LEVEL 2 – GYPSUM BOARD BEHIND AND APPLIED WALL COVERING AND WALLS AND CEILINGS IN MECHANICAL AND EQUIPMENT ROOMS. 3. LEVEL 4 – GYPSUM WALL BOARD ON INTERIOR WALLS FOR ALL TENANT AREAS. 4. LEVEL 5 – GYPSUM WALL BOARD ON FINISHED CEILINGS AND ALL COMMON AREA WALLS. CEILING NOTES: 1. PROVIDE ¼” CONTROL JOINT TO BE: FRY REGLET DRM-50-25 2-PC OR EQUAL. REFERENCE DETAIL A4/A503 2. PROVIDE ACCESS PANEL FOR RETURN AIR DUCT AT THIS LOCATION. ACCESS PANEL TO BE 1 HOUR RATED ASSEMBLY WITH SECURITY LATCH. FRAME AND PANEL ARE TO BE STANDARD FLANGE TYPE. REFERENCE SHEET H-103 FOR SIZE. 3. ALIGN FINISHED FACES. 4. PROVIDE ACCESS PANEL FOR SUPPLY AIR DUCT AT THIS LOCATION. ACCESS PANEL TO BE 1 HOUR RATED ASSEMBLY WITH SECURITY LATCH. FRAME AND PANEL ARE TO BE STANDARD FLANGE TYPE. REFERENCE SHEET H-103 FOR SIZE. 5. PROVIDE DRYWALL BULKHEAD. REFER TO SHEET A510 FOR SECTION VIEW. 6. . 7. . 8. . 9. . SCALE: 1/8" = 1'-0" 1 1st Floor RCP A111A 0 4'8'16' -Area A-Area A