Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutA111C 1st RCPProject:
Developer:
Sheet Number:
Carmel, Indiana 46032
317.705.7980 (fax)
355 City Center Drive
317.705.7979 (phone)
Architect:
By:
Sheet Title:
COPYRIGHT & OWNERSHIP OF DOCUMENTS
Architecture / Project Management:
Project Number:
Last Revision Date:
Set Issue Date
Drawn By Checked By
Sheet Issue DateTHE CONCOURSECarmel, IN 46032550 Monon BlvdPEDCOR DESIGN GROUP LLC
1st RCP
THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE
PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL
INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION
AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS
PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT,
INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL
INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND
PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND
PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN,
THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR
PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE
DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED,
MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE
SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R.
STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2023
JAMES R. STUTZMAN, AIA, Carmel, Indiana.
02/03/2023
A 111C
CITY REVIEW
Revision
ID
Transmittal
Set Date
Transmittal Set
Name Change Name Change
ID
01 2/3/23 Carmel Review
Friday, February 3, 2023, BIMcloud: pedcordesign - BIMcloud as a Service/Concourse/CONCOURSENOT FORCONSTRUCTIONE.3D.9
4.6
B.2 D E HD.2 K
44
6
55
C.3 D.5 J M
33
2
1
LFD.7
3.13.1
3.23.2
0.7B
1.51.5
1.81.8
0.10.1
C.4 C.80.7A B.3 D.6 E.6
GJGA
G2.3
GB GE
G1
G2
GIGGGCGHGA.9G.9A
G1.5
GF
G1.1
C C C C
C C C C
C C
C C
C C
C C
C
C
C C C C
CC
2
A111C
217'-8 61/64"
3'-2"3'-2"
OPEN
OPEN
OPEN
OPEN
9'-0"
OPEN
OPEN
OPEN
10'-0"
9'-0"
10'-0" A.F.F.
TOP RAMP
10'-4"
9'-6"
9'-6"
9'-6"
9'-0"
9'-0"
9'-6"
9'-0"
9'-0"
9'-0"9'-0"
9'-0"
9'-0"
A1
A301
B1
A302
C1
A302
A3
A506
A4
A506
CLG-06
B1
A506
B3
A506
C1
A506
D1
A506
A2
A506D1
A506
D1
A506
B1
A506
B1
A506
CP14 CP14 CP14
CP14
CP14
15
15
CP17CP17
CP17CP17
CP17CP17 CP17CP17 CP17CP17
CP17CP17
CP17CP17
CP18
CP18
CP18
CP18
CP18CP18
CP18CP18
CP18
SIM.
OPP.
SIM.
SIM.
SIM.
SIM.
SIM.
SIM.
REFLECTED CEILING PLAN NOTES
CP1 PROVIDE 1/4" WALL AND CEILING CONTROL JOINTS - FRY REGLET DRM-50-25-2-PC OR EQUAL.
REFER TO DETAILS XX/AXXX.
CP2 FINISH FACE OF GYP. BD. BULKHEAD TO ALIGN WITH FINISH FACE OF ADJACENT WALL.
CP3 SCONCE TO BE MOUNTED THE DIMENSION INDICATED FROM CENTER LINE OF ELEVATOR DOOR R.O.
AND AT XX A.F.F. TO CENTER OF BACK PLATE.
CP4 SUSPEND PENDANT AT 7'-6" A.F.F. TO THE BOTTOM OF FIXTURE.
CP5 SCONCE TO BE MOUNTED AT 5'-6" A.F.F. AND 2'-5" FROM CENTER LINE OF DOOR R.O., UNLESS NOTED
OTHERWISE.
CP6 SCONCE TO BE MOUNTED THE DIMENSION INDICATED FROM CENTERLINE OF ELEVATOR DOOR R.O.
AND AT 6'-0" A.F.F. TO CENTER OF BACK PLATE.
CP7 SUSPEND PENDANT AT 6'-0" A.F.F TO BOTTOM OF FIXTURE. EQUALLY SPACE PENDANTS CENTERED
ABOVE ISLAND KNEE WALL BELOW.
CP8 PAINT SIDE AND BOTTOM OF DRYWALL BULKHEAD PX. REFER TO SHEET AXXX FOR SECTION DETAIL.
CP9 SEE E SERIES FOR LIGHTING AND LOCATIONS.
CP10 SEE E SERIES FOR LIGHTING AND LOCATION IN STAIR WELLS.
CP11 PROVIDE 18"X18" ACCESS PANEL FOR WATER SHUT OFF VALVE AT THIS LOCATION. ACCESS PANEL TO BE
1 HOUR RATED ASSEMBLY WITH SECURITY LATCH. FRAME AND PANEL ARE TO BE CONCEALED FLANGE
TYPE REQUIRING DRYWALL FINISHING AND CEILING FINISH.
CP12 PROVIDE ACCESS PANEL FOR WATER SHUT OFF VALVE AT THIS LOCATION FOLLOWING WOOD PLANK
MANUFACTURER'S INSTRUCTIONS. INCLUDE PIECES AND TRIM AS RECOMMENDED BY MANUFACTURER
FOR PANEL ACCESS.
CP13 PROVIDE WOOD PLANK CEILING BULKHEAD. REFER TO COMMON AREA FINISHES FOR WOOD PLANK
SPECS. USE WOOD PLANK TRIM PIECE TO WRAP SIDES OF BULKHEAD.
CP14 EXTERIOR GYP. SOFFIT CONTROL JOINT.
CP15 EXTERIOR AWNING.
CP16 EXTERIOR CANOPY
CP17 2" LINEAR EXTERIOR SOFFIT VENT
CP18 CONCRETE BEAM ABOVE.
CP19 1' WIDE COVERAGE X 1" DEEP LINEAR METAL SOFFIT PANELS SYSTEM.
GENERAL CEILING NOTES:
1. CEILING HEIGHT DESIGNATED BY BENCHMARK ABOVER FINISHED FLOOR (AFF).
2. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM,
TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE
PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION.
3. PROVIDE FIRE RATED DAMPERS REQUIRED AT FIRE RATED WALLS.
4. TRADES TO COORDINATE THE HEIGHT OF FIRE SUPPRESSION LINES, ROOF DRAIN
LEADERS, ROOF STACK VENTS AND CONDENSATE LINES TO ALLOW FOR CEILING HEIGHTS
AS INDICATED ON THE REFLECTED CEILING PLAN.
5. SEE RCP PLANS AND SCHEDULE FOR CEILING HEIGHTS.
6. SEE E SERIES SHEETS FOR ELECTRICAL AND DATA LOCATIONS.
7. GYPSUM BOARD FINISHING:
A. COMPLY WITH ASTM C 840 STANDARD SPECIFICATION AND FINISHING OF GYPSUM
BOARD; GA 214 RECOMMENDED LEVELS OF GYPSUM BOARD FINISH; AND GA 216-2000
APPLICATION AND FINISHING OF GYPSUM BOARD.
B. PROVIDE GYPSUM BAORD MINIMUM FINISH LEVELS MEETING THE CRITERIA
ESTABLISHED IN GA 214 AS FOLLOWS:
1. LEVEL 1 – GYPSUM WALL BOARD PERMANENTLY CONCEALED FROM VIEW.
2. LEVEL 2 – GYPSUM BOARD BEHIND AND APPLIED WALL COVERING AND WALLS
AND CEILINGS IN MECHANICAL AND EQUIPMENT ROOMS.
3. LEVEL 4 – GYPSUM WALL BOARD ON INTERIOR WALLS FOR ALL TENANT AREAS.
4. LEVEL 5 – GYPSUM WALL BOARD ON FINISHED CEILINGS AND ALL COMMON
AREA WALLS.
CEILING NOTES:
1. PROVIDE ¼” CONTROL JOINT TO BE: FRY REGLET DRM-50-25 2-PC OR EQUAL. REFERENCE
DETAIL A4/A503
2. PROVIDE ACCESS PANEL FOR RETURN AIR DUCT AT THIS LOCATION. ACCESS PANEL TO BE
1 HOUR RATED ASSEMBLY WITH SECURITY LATCH. FRAME AND PANEL ARE TO BE
STANDARD FLANGE TYPE. REFERENCE SHEET H-103 FOR SIZE.
3. ALIGN FINISHED FACES.
4. PROVIDE ACCESS PANEL FOR SUPPLY AIR DUCT AT THIS LOCATION. ACCESS PANEL TO BE
1 HOUR RATED ASSEMBLY WITH SECURITY LATCH. FRAME AND PANEL ARE TO BE
STANDARD FLANGE TYPE. REFERENCE SHEET H-103 FOR SIZE.
5. PROVIDE DRYWALL BULKHEAD. REFER TO SHEET A510 FOR SECTION VIEW.
6. .
7. .
8. .
9. .
C C C C
C C C C
C C
C C
C C
C C
C
C
C C C C
6"4'-10 3/8"4'-8 1/2"4'-8 1/2"10'-1 3/8"2'-9 1/2"8'-0"8'-0"8'-0"4'-1 1/2"
2'-0"2'-9"8'-0"8'-0"16'-0"8'-2 1/8"
4'-2 3/8"4'-2 3/8"
4'-11"1'-4 5/8"2'-6"2'-6"2'-6"1'-4 5/8"5'-0 1/4"
5'-1"5'-1"5'-1"2'-5 1/4"2'-2 1/2"1'-5 5/8"2'-10 1/4"2'-10 1/2"6'-1"6'-1"6'-1"2'-6 1/2"EQ.6'-6"EQ.3'-7 1/8"3'-7 3/4"6'-0"2'-6 1/2"
2'-6 1/4"6'-9"6'-9"6'-9"3'-7 1/2"6'-1"6'-9"3'-0"1'-4"8'-0"8'-0"8'-0"EQ.2'-6 5/8"8'-0"8'-0"3'-0"
2'-6 5/8"2'-8 1/8"EQ.2'-0 5/8"5'-0"5'-0"2'-0"
5'-0"5'-0"2'-0"2'-10"4'-2"2'-10"4'-2"EQ.EQ.1'-8"5'-11 1/2"1'-8"
1'-10"6'-0"
7'-6"7'-6"7'-6"3'-1"
2'-5"5'-10"5'-10"2'-5"1'-5 3/4"3'-3 1/2"4'-0"3'-3 1/2"1'-8"2'-2"2'-10 5/8"2'-0"
11"
2'-2 1/2"
4'-2 3/4"4'-2 3/4"
1'-1 1/4"
9'-6"
9'-6"
9'-6"
9'-6"
9'-6"
9'-6"
8'-6"
9'-6"
8'-0"
9'-1"
8'-0"
9'-0"
9'-6"
9'-6"
9'-0"
9'-0"
9'-0"9'-0"
9'-0"
8'-0"8'-0"
9'-0"
135.0°
CP1
CP2CP2
CP2CP2
CP2CP2
CP2CP2CP2CP2CP2
CP1
CP1CP1
CP12 CP12CP12
CP7CP7CP7CP7
CP4 CP4
CP3
CP3
CP1
CP3
CP3
CP13
CP1
CP1
CP1
SCALE: 1/8" = 1'-0"
1 1st Floor RCP
A111C 0 4'8'16'
SCALE: 1/4" = 1'-0"
2 Enlarged RCP - 1st Floor
A111C
0 2'4'8'