Loading...
HomeMy WebLinkAboutA307 Interior Wall Sections - Trash ChutesProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateTHE CONCOURSECarmel, IN 46032550 Monon BlvdPEDCOR DESIGN GROUP LLC Interior Wall Sections - Trash Chutes THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2023 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 02/03/2023 A307 CITY REVIEW Revision ID Transmittal Set Date Transmittal Set Name 01 2/3/23 Carmel Review A B C D 1 1 2 2 3 3 4 4 A B C D NOT FORCONSTRUCTIONFriday, February 3, 2023, BIMcloud: pedcordesign - BIMcloud as a Service/Concourse/CONCOURSEA3 A307 +17'-6" 2 2nd Floor +28'-2" 3 3rd Floor +38'-10" 4 4th Floor +49'-6" 5 5th Floor3'-0" MIN.2'-6 1/2" POST TENSIONED SLAB, REF. S-SERIES DWGS. FOR STRUCT. EMBED DETAILS AT FLOOR STRUCT. CMU WALL, REFERENCE S-SERIES DRAWINGS FOR REINFORCING APARTMENT APARTMENT APARTMENT APARTMENT ROOF TRUSSES, REFERENCE S-SERIES DRAWINGS FOR STRUCTURAL REQUIREMENTS FLOOR TRUSSES, REFERENCE S-SERIES DRAWINGS FOR STRUCTURAL REQUIREMENTS TRASH GARAGE EQUIPMENT N.I.C. T/CHUTE 3'-0" BEYOND T/ROOF STAIR #1 STAIR #1 STAIR #1 STAIR #1 UL - U417: 2 HOUR SHAFT WALL SUPPORTED BY SLAB AND BEAMS ALONG CORRIDOR AT RESIDENTIAL FLOORS. LVL OR TRUSS GIRDER, WRAPPED 2 LAYERS OF 5/8" GYP. BD.,FIRE WALL HANGERS FOR TRUSSES, REFERENCE S- SERIES DRAWINGS.TRASH CHUTEFLASH. COLLAR BY CHUTE CONTR. ROOF FLASH. & CURB BY ROOF. CONTR. 4 A504 4 A504 F5 A414 6'-8"2'-8 3/4"4'-8 7/8"5'-3 1/4"3'-0"7'-4"17'-6" 28'-2" 38'-10" 49'-6" 60'-2" CONC. FOUNDATION, REF. S-SERIES DWGS. POST TENSIONED SLAB, REF. S-SERIES DWGS. FOR STRUCT. EMBED DETAILS AT FLOOR STRUCT. 3/4" EIFS VENEER CMU WALL, REFERENCE S-SERIES DRAWINGS FOR REINFORCING CORRIDOR CORRIDOR CORRIDOR CORRIDOR ROOF TRUSSES, REFERENCE S-SERIES DRAWINGS FOR STRUCTURAL REQUIREMENTS. INSULATED LOAD BEARING STUD WALL ASSEMBLY, REFERENCE S- SERIES FOR STRUCTURAL REQUIREMENTS. 1-1/2" ACOUSTIC TOPPING, REFERENCE A520 FOR ACOUSTIC TOPPING NOTES. FLOOR TRUSSES, REFERENCE S- SERIES DRAWINGS FOR STRUCTURAL REQUIREMENTS. GARAGE GARAGE GARAGE GARAGE SERVICE CORRIDOR TRASH ROOM TRASHROOM TRASHROOM TRASHROOM TRASHROOM 2" EXPANSION JOINT, TYP. EQUIPMENT N.I.C.MIN.FIRESTOPPING AT HEAD OF WALL. REF. S-SERIES FOR BRACING. REF. S-SERIES FOR FLOOR ASSEMBLY AND SUPPORT T/CHUTE 3'-0" BEYOND T/ROOF W/ FLASH. COLLAR & ROOF CURB SHAFT WALL ASSEMBLY SYSTEM, BEYOND TYP. TYP. SLOPED CONCRETE DECK NOTES: 1. PROVIDE MINERAL WOOL INSULATION (ROCKWOOL) INSIDE CFS BOX HEADERS AND CRIPPLE STUD CAVITIES SO ENTIRE WALL IS INSULATED. 2. PAINT ALL EXPOSED STEEL LINTELS WITH COLOR SPECIFIED BY ARCHITECT. 3. PROVIDE STAINLESS STEEL LINTELS WHERE SUPPORTING LIMESTONE. 4. FOR EIFS CORNICE PROFILES, SEE SHEETS A321, A322, AND A323 5. ALL STEEL AND ALUMINUM ON BALCONIES IS PAINTED W/ TNEMEC SYSTEM. 6. INSULATE THE CAVITIES IN STOREFRONT SYSTEMS BETWEEN FRAMES. SPRAY FOAM SHIM SPACES FOR AIR TIGHT SEALS. 7. REFER TO EIFS DETAILS FOR TYPICAL EIFS REQUIREMENTS AND OTHER REQUIREMENTS IMPLIED WHEN ADJOINING OTHER SYSTEMS. 8. WOOD BLOCKING AND PLYWOOD AT TYPE I CONSTRUCTION ARE FIRE RETARDANT TREATED, INCLUDING ANY WOOD ON THE LOW ROOF AND PARAPETS AT THE SECOND FLOOR, ALONG WITH CORRESPONDING COPING AND PARAPET DETAILS. 9. USE PRESERVATIVE TREATED EXTERIOR PLYWOOD SHEATHING AT ROOF SIDE OF PARAPETS AND PANELS AT ROOF WALLS, PORCH WALLS OR CANOPY AREAS. 10. PROVIDE AIR MOISTURE BARRIER PER MANUFACTURE’S REQUIREMENTS. DETAILS AT TRANSITIONS FROM WALLS, SLABS, LEDGES, FLASHINGS AND OPENINGS REQUIRE SPECIAL ATTENTION. COMMON DETAILS ARE SHOWN IN VARIOUS WALL SECTIONS DETAILS, WINDOW, DOOR AND STOREFRONT DETAILS, AND THE A500 SERIES. 11. SPACE IN EIFS CORNICE PROFILES INDICATES FRAMING DELEGATED FOR COORDINATION BETWEEN FRAMERS AND EIFS SUPPLIER. 12. PROVIDE MORTAR NET AT THE BASE OF EACH MASONRY VENEER WALL ABOVE ANY WALL FLASHING. A1 A307 1'-5 3/8"ROOF DRAIN , REF. P-SERIES TRASH CHUTE & S.M. FLASH. COLLAR ON ROOF CURB BY ROOFING CONTR. EXHAUST FAN, REF. M-SERIES TRASH ROOM ROOF ELEVATOR SHAFT ROOF F5 A414 2'-8 3/4"5'-0" 5'-0" 567891'-3 1/2"2'-4 3/8"6'-3 3/8"2'-10 7/8" A3 A307 TRASH CHUTE & S.M. FLASHING COLLAR ON ROOF CURB BY ROOFING CONTRACTOR EXHAUST FAN, REF. M-SERIES STAIR SHAFT A2 A307 A2 A307 APARTMENT ROOF TRUSSES, REF. S-SERIES DRAWINGS TRASH ROOM TRASH CHUTEEXHAUST DUCT, REF. M-SERIES EXHAUST FAN, REF. M-SERIES TRASH CHUTE 1'-5 1/8"9 5/8"6'-6 1/4"2'-11 7/8"5"7'-2 5/8"10 1/8"6'-5 3/4"5 1/4"2'-1 3/8"5 1/4"2402017 7/8" 6'-10 5/8"1'-1 1/2" A1 A3079'-0 7/8"7 5/8"8'-9 5/8"7 5/8"3 1/8"5 1/2"245 Trash 245 7 5/8"9'-4 1/4"1 1/4"3" 5 1/4" 2'-3" 7 5/8" F5 A414 SCALE: 3/8" = 1'-0" A2 Trashroom (NW) Wall Section A307 0 2'4'6' SCALE: 3/8" = 1'-0" A1 Trashroom (SE) Wall Section A307 0 2'4'6' SCALE: 1/4" = 1'-0" B4 SE Trash Chute - Enlarged Roof Plan A307 0 2'4'8' SCALE: 1/4" = 1'-0" B3 NW Trash Chute - Enlarged Roof Plan A307 0 2'4'8' SCALE: 3/8" = 1'-0" A3 Trash Room (NW) Section A307 0 2'4'6' SCALE: 1/2" = 1'-0" C4 Trash Room 220, 320, 420 and 520 A307 0 1'2'4' SCALE: 1/4" = 1'-0" C3 Trashroom 245, 345, 445 and 545 A307 0 2'4'8'