Loading...
HomeMy WebLinkAboutA309 Common Interior Wall DetailsProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateTHE CONCOURSECarmel, IN 46032550 Monon BlvdPEDCOR DESIGN GROUP LLC Common Interior Wall Details THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2023 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 02/03/2023 A309 CITY REVIEW Revision ID Transmittal Set Date Transmittal Set Name 01 2/3/23 Carmel Review A B C D E 1 1 2 2 3 3 4 4 5 5 6 6 A B C D E NOT FORCONSTRUCTIONFriday, February 3, 2023, BIMcloud: pedcordesign - BIMcloud as a Service/Concourse/CONCOURSER-21 HD BATT INSULATION BEAM, REF. S-SERIES DRAWINGS LIGHTWEIGHT TOPPING AND ACOUSTIC PAD FLOOR TRUSS 1 LAYER 5/8" GYP. BOARD ON RESILIENT CHANNELS SHAFTAPARTMENT FLOOR SHEATHING SHAFT LINER WALL SYSTEM 2 LAYERS 5/8" GYPSUM WALL BOARD, CONTINUOUS AROUND BEAM 1 LAYER 5/8" GYPSUM BD. ON RESILIENT CHANNELS, TYPE & SPACING PER UL LISTED ASSEMBLY FLOOR TRUSSES AND DECKING PER UL LISTED ASSEMBLY - SEE S-SERIES DRAWINGS LIGHTWEIGHT CONCRETE TOPPING & ACOUSTIC PAD WALL PLATE & CONNECTION, REF. S- SERIES DRAWINGS CORRIDOR APARTMENT FLOOR FINISHES & TRIM, REF. ROOM FINISH SCHEDULE & INTERIOR DETAILS R-11 BATT INSULATION INSIDE FLOOR ASSEMBLY, NO GAPS DRAFTSTOP SHEATHING CONTINUOUS 9'-0" 9'-1 1/8" 1 HOUR RATING - FLOOR/CEILING PER UL DESIGN L563 ELEVATIONS ASSUME T/FLR SHEATHING IS 0'-0" 9'-0" 9'-1 1/8" 1 LAYER 5/8" GYPSUM BD. ON RESILIENT CHANNELS, TYPE & SPACING PER UL LISTED ASSEMBLY CORRIDOR APARTMENT FIRE SEALANT AT HEAD OF WALL WOOD ROOF TRUSSES & DECKING PER UL LISTED ASSEMBLY, REF. S-SERIES DRAWINGS CONTINUOUS DRAFTSTOPPING SHEATHING FOR SHEAR PANELS, REF. S-SERIES DRAWINGS 5/8" GYPSUM BOARD, LISTED FOR RATED WALL R-19 BATT INSULATION (MINERAL WOOL WHEN BUILDING SEQUENCE REQUIRES INSULATION PRIOR TO WATER TIGHT CONDITIONS) 2X6 WOOD STUDS, MIN. 16" O.C. FOR FIRE RATING, REF. S-SERIES DRAWINGS FOR STRUCTURAL REQUIRED SPACING CORRIDOR APARTMENT 9'-0" 9'-1 1/8" BEAM, REF. S- SERIES DRAWINGS ROOF TRUSS SHAFTCORRIDOR 2 LAYERS 5/8" GYPSUM WALL BOARD, CONTINUOUS AROUND BEAM R-11 BATT INSULATION SHAFT LINER WALL SYSTEM PLYWOOD DRAFT STOP ABOVE EVERY DEMISING WALL TYP. R-11 BATT INSULATION FLOOR TRUSS, SEE S- SERIES DRAWINGS 2X4 WOOD STUD WALL, MIN. 16" O.C. FOR FIRE RATING, REF. S- SERIES DRAWINGS FOR STRUCTURAL REQUIREMENTS DRAFTSTOPPING AS REQUIRED TO LIMIT 100 SF AREAS PER CODE 5/8" GYPSUM BOARD, LISTED FOR RATED WALL SHEATHING FOR SHEAR PANELS, REF. S-SERIES DRAWINGS 5/8" GYPSUM WALL BOARD, LISTED FOR RATED WALL R-19 BATT INSULATION PLAN VIEW 1 HOUR RATING WP 3370 9'-0" 9'-1 1/8" ROOF TRUSSES, REFERENCE S-SERIES FOR STRUCTURAL REQUIREMENTS. R-11 BATT INSULATION DRAFTSTOPPING ABOVE EVERY DEMISING WALL TYP. 2X WOOD BLOCKING, REF. S-SERIES DRAWINGS DRAFTSTOPPING, CONTINUOUS 2 A504 CONCRETE BUMPER WALL EIFS CLADDING EXPANSION JOINT FLASHING FLOOR TRUSSES AND DECKING PER UL LISTED ASSEMBLY - SEE S-SERIES DRAWINGS LIGHTWEIGHT CONCRETE TOPPING & ACOUSTIC PAD FLOOR FINISHES & TRIM, REF. ROOM FINISH SCHEDULE & INTERIOR DETAILS 1 LAYER 5/8" GYPSUM BD. ON RESILIENT CHANNELS, TYPE & SPACING PER UL LISTED ASSEMBLY CONTINUOUS BLOCKING BETWEEN TRUSSES FOR EXPANSION JOINT CONNECTION FLASHING TAPE, HOT-AIR WELDED STEEL TUBE BEAM EXTERIOR WOOD SHEATHING 2X WOOD BLOCKING 6" TAPERED RIGID INSULATION PVC ROOFING MEMBRANE PREFINISHED MTL DRIP EDGE 1 1/2" MTL DECK 2X4 WOOD STUD WALL, MIN. 16" O.C. FOR FIRE RATING, REF. S-SERIES DRAWINGS FOR STRUCTURAL REQUIREMENTS R-19 MINERAL WOOL INSULATION 5/8" GYPSUM BOARD, LISTED FOR RATED WALL SHEATHING FOR SHEAR PANELS, REF. S-SERIES DRAWINGS 3/4" AIR SPACE ALUMINUM CLIPS SPACE & ATTACHED TO WOOD FRAMING PER UL U347 REF. S-SERIES DRAWINGS FOR PRE-FAB. BLOCKING PANELS. FIRE & DRAFTSTOPPING REQ. 2X4 WOOD STUD WALL, MIN. 16" O.C. FOR FIRE RATING, REF. S-SERIES DRAWINGS FOR STRUCTURAL REQUIREMENTS R-19 MINERAL WOOL INSULATION 5/8" GYPSUM BOARD, LISTED FOR RATED WALL SHEATHING FOR SHEAR PANELS, REF. S-SERIES DRAWINGS ALUMINUM CLIPS SPACE & ATTACHED TO WOOD FRAMING PER UL U347 5/8" GYPSUM BOARD, LISTED FOR RATED WALL "H" STUD ALUMINUM CLIPS SPACE & ATTACHED TO WOOD FRAMING PER UL U347 3/4" AIR SPACE PLAN VIEW 1 HOUR RATING UL DESIGN U347 R-11 BATT INSULATION 2X4 WOOD STUD WALL, MIN. 16" O.C. FOR FIRE RATING, REF. S-SERIES DRAWINGS FOR STRUCTURAL REQUIREMENTS SHEATHING FOR SHEAR PANELS, REF. S-SERIES DRAWINGS ROOF TRUSSES, SEE S-SERIES DRAWINGS FOR STRUCTURAL REQUIREMENTS ALUMINUM CLIPS SPACE & ATTACHED TO WOOD FRAMING PER UL U347 5/8" GYPSUM BOARD, LISTED FOR RATED WALL CONCRETE WALL FLOOR TRUSSES AND DECKING PER UL LISTED ASSEMBLY - SEE S-SERIES DRAWINGS LIGHTWEIGHT CONCRETE TOPPING & ACOUSTIC PAD FLOOR FINISHES & TRIM, REF. ROOM FINISH SCHEDULE & INTERIOR DETAILS 1 LAYER 5/8" GYPSUM BD. ON RESILIENT CHANNELS, TYPE & SPACING PER UL LISTED ASSEMBLY PLYWOOD SHEATHING 9'-0" 9'-1 1/8" R-11 BATT INSULATION INSIDE FLOOR ASSEMBLY LIGHTWEIGHT TOPPING AND ACOUSTIC PAD FLOOR TRUSS 1 LAYER 5/8" GYP. BOARD ON RESILIENT CHANNELS CORRIDORSHAFT BEAM, REF. S- SERIES DRAWINGS FIRE SEALANT 2 LAYERS 5/8" GYPSUM WALL BOARD, CONTINUOUS AROUND BEAM 9'-0" 9'-1 1/8" R-21 HD BATT INSULATION ROOF TRUSS CORRIDORSHAFT SHAFT LINER WALL SYSTEM C-H STUD 2 LAYERS 5/8" GYPSUM WALL BOARD, CONTINUOUS AROUND BEAM NOTES: 1. PROVIDE MINERAL WOOL INSULATION (ROCKWOOL) INSIDE CFS BOX HEADERS AND CRIPPLE STUD CAVITIES SO ENTIRE WALL IS INSULATED. 2. PAINT ALL EXPOSED STEEL LINTELS WITH COLOR SPECIFIED BY ARCHITECT. 3. PROVIDE STAINLESS STEEL LINTELS WHERE SUPPORTING LIMESTONE. 4. FOR EIFS CORNICE PROFILES, SEE SHEETS A321, A322, AND A323 5. ALL STEEL AND ALUMINUM ON BALCONIES IS PAINTED W/ TNEMEC SYSTEM. 6. INSULATE THE CAVITIES IN STOREFRONT SYSTEMS BETWEEN FRAMES. SPRAY FOAM SHIM SPACES FOR AIR TIGHT SEALS. 7. REFER TO EIFS DETAILS FOR TYPICAL EIFS REQUIREMENTS AND OTHER REQUIREMENTS IMPLIED WHEN ADJOINING OTHER SYSTEMS. 8. WOOD BLOCKING AND PLYWOOD AT TYPE I CONSTRUCTION ARE FIRE RETARDANT TREATED, INCLUDING ANY WOOD ON THE LOW ROOF AND PARAPETS AT THE SECOND FLOOR, ALONG WITH CORRESPONDING COPING AND PARAPET DETAILS. 9. USE PRESERVATIVE TREATED EXTERIOR PLYWOOD SHEATHING AT ROOF SIDE OF PARAPETS AND PANELS AT ROOF WALLS, PORCH WALLS OR CANOPY AREAS. 10. PROVIDE AIR MOISTURE BARRIER PER MANUFACTURE’S REQUIREMENTS. DETAILS AT TRANSITIONS FROM WALLS, SLABS, LEDGES, FLASHINGS AND OPENINGS REQUIRE SPECIAL ATTENTION. COMMON DETAILS ARE SHOWN IN VARIOUS WALL SECTIONS DETAILS, WINDOW, DOOR AND STOREFRONT DETAILS, AND THE A500 SERIES. 11. SPACE IN EIFS CORNICE PROFILES INDICATES FRAMING DELEGATED FOR COORDINATION BETWEEN FRAMERS AND EIFS SUPPLIER. 12. PROVIDE MORTAR NET AT THE BASE OF EACH MASONRY VENEER WALL ABOVE ANY WALL FLASHING. APARTMENTCORRIDOR ROOF TRUSS, REF. S-SERIES DRAWINGS ROOF R-11 BATT INSULATION WOOD STUD WALL, 5/8" GYPSUM WALLBOARD EITHER SIDE CONTINUOUS DRAFTSTOPPING SCALE: 1 1/2"= 1'-0" D3 Shaft Section Detail A309 0 6''12''18'' SCALE: 1 1/2"= 1'-0" D1 Section Detail A309 0 6''12''18'' SCALE: 1 1/2"= 1'-0" B2 Section Detail A309 0 6''12''18'' Plan SCALE: 1 1/2"= 1'-0" C3 Shaft Section Detail A309 0 6''12''18'' SCALE: 1 1/2"= 1'-0" D4 Demising Wall Section Detail A309 0 6''12''18'' SCALE: 1 1/2"= 1'-0" B4 Demising Wall Section Detail A309 0 6''12''18'' SCALE: 1 1/2"= 1'-0" E1 Section Detail A309 0 6''12''18'' SCALE: 1 1/2"= 1'-0" A3 Shaft Section Detail A309 0 6''12''18'' SCALE: 1 1/2"= 1'-0" E5 Firewall Section Detail A309 0 6''12''18'' SCALE: 1 1/2"= 1'-0" D5 Firewall Section Detail A309 0 6''12''18'' SCALE: 1 1/2"= 1'-0" E4 Demising Wall Section Detail A309 0 6''12''18'' SCALE: 1 1/2"= 1'-0" B5 Firewall Section Detail A309 0 6''12''18'' SCALE: 1 1/2"= 1'-0" E2 Section Detail A309 0 6''12''18'' SCALE: 1 1/2"= 1'-0" D2 Shaft Section Detail A309 0 6''12''18'' SCALE: 1 1/2"= 1'-0" C2 Shaft Section Detail A309 0 6''12''18'' SCALE: 1 1/2"= 1'-0" B1 Section Detail A309 0 6''12''18''