Loading...
HomeMy WebLinkAboutA310 Wall SectionsProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateTHE CONCOURSECarmel, IN 46032550 Monon BlvdPEDCOR DESIGN GROUP LLC Wall Sections THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2023 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 02/03/2023 A 3 10 CITY REVIEW Revision ID Transmittal Set Date Transmittal Set Name 01 2/3/23 Carmel Review A B C D E 1 1 2 2 3 3 4 4 5 5 A B C D E NOT FORCONSTRUCTIONFriday, February 3, 2023, BIMcloud: pedcordesign - BIMcloud as a Service/Concourse/CONCOURSE5 A514 B5 A310 A1 A321 A4 A321 C5 A310 C3 A323 B4 A323 A5 A310 A1 A322 D5 A310 D4 A310 +17'-6" 2nd Floor +28'-2" 3rd Floor +38'-10" 4th Floor +49'-6" 5th Floor +72'-6 1/8" High Roof 5'-8 1/2" EIFS CORNICE PROFILE EP6.1 W/ PVC MEMBRANE OVER PLYWOOD W/ METAL DRIP EDGE BRICK W/TABLE PROFILE SB1 EIFS CORNICE PROFILE EP6.10 W/ PVC MEMBRANE OVER PLYWOOD W/ METAL DRIP EDGE BALCONY CORNICE PROFILE BP1.1 EIFS CORNICE PROFILE EP5.1 EIFS CORNICE PROFILE EP2.14 EIFS WRAPPED COLUMN TREX DECK OVER STEEL BALCONY FRAMING BALCONY SLOPED TO DRAIN, REF. S- SERIES DWGS. BRICK VENEER TREX DECK OVER STEEL BALCONY FRAMING TREX DECK OVER STEEL BALCONY FRAMING 1-1/2" THICK PATTERNED EIFS VENEER T/ GYPCRETE T/ GYPCRETE T/ GYPCRETE 1" RIGID INSULATION CONC. FOUNDATION, REF. S-SERIES DWGS. POST TENSIONED SLAB, REF. S-SERIES DWGS. FOR STRUCT. EMBED DETAILS AT FLOOR STRUCT. EIFS FINIAL R-21 HD BATT INSULATION EIFS HEAD & DOOR SURROUND STRUCTURAL COLUMN, REF. S-SERIES DRAWINGS FOAMED IN PLACE INSULATION EIFS HEAD & DOOR SURROUND EIFS HEAD & DOOR SURROUND PATIO DOOR MINERAL WOOL INSULATION CONTINUOUS, MIN. 2' ABOVE BASE OF ROOF TRUSS. D4 A311 5 A514 B5 A310 B5 A501 A1 A322 A1 A321 A4 A321 B5 A310 C5 A310 C3 A323 B4 A323 SIM.D4A310E2 A310 EP6.1 EP6.7 E47 E14 E13 E1 E1 E31 E37 E47 E47 E14 E26 SIM. REFER TO ELEVATION BRICK VENEER W/ WEEPS 24" O.C. FLEXIBLE FLASHING PAINTED, GALVANIZED LOOSE LAID LINTEL, REF. S-SERIES DRAWINGS DOOR FRAME, SEE SCHEDULE AND FRAME TYPE ELEVATION 1" CONTINUOUS INSULATION TERMINATION BAR AND SEALANT METAL FLASHING 5/8" GYP. BOARD BATT INSULATION PRE-APPLIED VAPOR BARRIER OR LIQUID APPLIED VAPOR PERMEABLE AIR BARRIER PAINTED WD. CASING PATIO DOOR WOOD HEADER FILL CAVITY W/ FOAM SEALANT BACKER ROD & SEALANT DOOR FRAME ZIP BOARD OR EXT. SHEATHING BRICK MOULD EIFS TRIM 3/4" EIFS PRE-FINISHED METAL FLASHING, COUNTER FLASHED FROM DOOR OPENING 1" PLYWOOD BEVELED EDGE PRE-FIN. METAL FLASHING TREX DECK SHIM OVER FURRING AS REQUIRED TO LEVEL TREX BOARD AT DOORWAY. INFILL SPACE UNDER DOOR THRESHOLD WITH RIPPED TREX. REFER TO ELEVATION 5/8" GYP. BOARD BATT INSULATION PRE-APPLIED VAPOR BARRIER OR LIQUID APPLIED VAPOR PERMEABLE AIR BARRIER PAINTED WD. CASING PATIO DOOR WOOD HEADER INSULATION DOOR FRAME ZIP BOARD OR EXT. SHEATHING BRICK MOULD METAL DRIP FLASHING W/ WEEPS PER MANUFACTURER'S REQUIREMENTS EIFS TRIM ADHESIVE BACKED FLASHING BACKER ROD AND SEALANT NOTES: 1. PROVIDE MINERAL WOOL INSULATION (ROCKWOOL) INSIDE CFS BOX HEADERS AND CRIPPLE STUD CAVITIES SO ENTIRE WALL IS INSULATED. 2. PAINT ALL EXPOSED STEEL LINTELS WITH COLOR SPECIFIED BY ARCHITECT. 3. PROVIDE STAINLESS STEEL LINTELS WHERE SUPPORTING LIMESTONE. 4. FOR EIFS CORNICE PROFILES, SEE SHEETS A321, A322, AND A323 5. ALL STEEL AND ALUMINUM ON BALCONIES IS PAINTED W/ TNEMEC SYSTEM. 6. INSULATE THE CAVITIES IN STOREFRONT SYSTEMS BETWEEN FRAMES. SPRAY FOAM SHIM SPACES FOR AIR TIGHT SEALS. 7. REFER TO EIFS DETAILS FOR TYPICAL EIFS REQUIREMENTS AND OTHER REQUIREMENTS IMPLIED WHEN ADJOINING OTHER SYSTEMS. 8. WOOD BLOCKING AND PLYWOOD AT TYPE I CONSTRUCTION ARE FIRE RETARDANT TREATED, INCLUDING ANY WOOD ON THE LOW ROOF AND PARAPETS AT THE SECOND FLOOR, ALONG WITH CORRESPONDING COPING AND PARAPET DETAILS. 9. USE PRESERVATIVE TREATED EXTERIOR PLYWOOD SHEATHING AT ROOF SIDE OF PARAPETS AND PANELS AT ROOF WALLS, PORCH WALLS OR CANOPY AREAS. 10. PROVIDE AIR MOISTURE BARRIER PER MANUFACTURE’S REQUIREMENTS. DETAILS AT TRANSITIONS FROM WALLS, SLABS, LEDGES, FLASHINGS AND OPENINGS REQUIRE SPECIAL ATTENTION. COMMON DETAILS ARE SHOWN IN VARIOUS WALL SECTIONS DETAILS, WINDOW, DOOR AND STOREFRONT DETAILS, AND THE A500 SERIES. 11. SPACE IN EIFS CORNICE PROFILES INDICATES FRAMING DELEGATED FOR COORDINATION BETWEEN FRAMERS AND EIFS SUPPLIER. 12. PROVIDE MORTAR NET AT THE BASE OF EACH MASONRY VENEER WALL ABOVE ANY WALL FLASHING. DOOR LEAF THRESHOLD SET IN ASPHALT MASTIC GYPCRETE PLYWOOD DECK DOOR FRAME BEYOND BRICK SILL W/ WEEPS 24" O.C. FLEXIBLE FLASHING 1" CONTINUOUS INSULATION METAL FLASHING PRE-APPLIED VAPOR BARRIER OR LIQUID APPLIED VAPOR PERMEABLE AIR BARRIER GROUT BACKER ROD AND SEALANT DECKING SCALE: 3/8" = 1'-0" E2 Wall Section A310 0 2'4'6' NOT TO SCALE E1 Perspective A310 SCALE: 3/8" = 1'-0" D4 Partial Elevation A310 0 2'4'6' SCALE: 1 1/2"= 1'-0" B5 Patio Door Head - Brick A310 0 6''12''18'' SCALE: 1 1/2"= 1'-0" A5 Section Detail A310 0 6''12''18'' SCALE: 1 1/2"= 1'-0" C5 Patio Door Head - EIFS A310 0 6''12''18'' SCALE: 1 1/2"= 1'-0" D5 Patio Door Sill A310 0 6''12''18''