Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A318 Wall Sections
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateTHE CONCOURSECarmel, IN 46032550 Monon BlvdPEDCOR DESIGN GROUP LLC Wall Sections THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2023 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 02/03/2023 A 3 18 CITY REVIEW Revision ID Transmittal Set Date Transmittal Set Name 01 2/3/23 Carmel Review A B C D E 1 1 2 2 3 3 4 4 5 5 6 6 A B C D E NOT FORCONSTRUCTIONFriday, February 3, 2023, BIMcloud: pedcordesign - BIMcloud as a Service/Concourse/CONCOURSEE.3D.9B.2 D ED.2 4 C.3 D.5 3 FD.7 3.1 3.2 0.7B 1.5 1.8 0.10.1 C.4 C.80.7A B.3 D.6 E.6 GA GB GE GGGCGA.9G.9A GF 1'-11 3/8"1'-10 7/8"4 1/4"1'-11 3/8"1'-0"9 1/4"1'-11 3/8"1'-0"9 1/4"1'-11 3/8"1'-0"9 1/4"9 1/4"1'-0"1'-11 3/8"1'-11 3/8"1'-0"9 1/4"1'-11 3/8"1'-0"9 1/4"1'-11 3/8"10 1/2"1'-11 3/8"10 1/2"1'-11 3/8"1'-0"9 1/4"10 1/2"1'-11 3/8" 1 4'-4 1/4" 2'-1 3/8"2'-1 1/8"3'-7"5'-3 1/4"3'-10 1/8"3'-7 1/8"11'-8 1/2"1'-11 1/8"26'-10"1'-11 1/8"21'-5 3/8"1'-11 1/8" 1'-11 1/8"2'-6 7/8"16'-3 3/4"2'-6 7/8" FACE OF PARAPET FRAMING CENTER OF STEEL BEAM AT PARAPET E3 A318E1 A320 D3 A319 E4 A320 E3 A320 E1 A318 B3 A320 2'-9 7/8" 19'-8 3/4"11'-1 1/2"23'-7 7/8"3'-10 1/8"13'-0 1/4"2'-9 7/8" B1 A320 NOTES: 1. PROVIDE MINERAL WOOL INSULATION (ROCKWOOL) INSIDE CFS BOX HEADERS AND CRIPPLE STUD CAVITIES SO ENTIRE WALL IS INSULATED. 2. PAINT ALL EXPOSED STEEL LINTELS WITH COLOR SPECIFIED BY ARCHITECT. 3. PROVIDE STAINLESS STEEL LINTELS WHERE SUPPORTING LIMESTONE. 4. FOR EIFS CORNICE PROFILES, SEE SHEETS A321, A322, AND A323 5. ALL STEEL AND ALUMINUM ON BALCONIES IS PAINTED W/ TNEMEC SYSTEM. 6. INSULATE THE CAVITIES IN STOREFRONT SYSTEMS BETWEEN FRAMES. SPRAY FOAM SHIM SPACES FOR AIR TIGHT SEALS. 7. REFER TO EIFS DETAILS FOR TYPICAL EIFS REQUIREMENTS AND OTHER REQUIREMENTS IMPLIED WHEN ADJOINING OTHER SYSTEMS. 8. WOOD BLOCKING AND PLYWOOD AT TYPE I CONSTRUCTION ARE FIRE RETARDANT TREATED, INCLUDING ANY WOOD ON THE LOW ROOF AND PARAPETS AT THE SECOND FLOOR, ALONG WITH CORRESPONDING COPING AND PARAPET DETAILS. 9. USE PRESERVATIVE TREATED EXTERIOR PLYWOOD SHEATHING AT ROOF SIDE OF PARAPETS AND PANELS AT ROOF WALLS, PORCH WALLS OR CANOPY AREAS. 10. PROVIDE AIR MOISTURE BARRIER PER MANUFACTURE’S REQUIREMENTS. DETAILS AT TRANSITIONS FROM WALLS, SLABS, LEDGES, FLASHINGS AND OPENINGS REQUIRE SPECIAL ATTENTION. COMMON DETAILS ARE SHOWN IN VARIOUS WALL SECTIONS DETAILS, WINDOW, DOOR AND STOREFRONT DETAILS, AND THE A500 SERIES. 11. SPACE IN EIFS CORNICE PROFILES INDICATES FRAMING DELEGATED FOR COORDINATION BETWEEN FRAMERS AND EIFS SUPPLIER. 12. PROVIDE MORTAR NET AT THE BASE OF EACH MASONRY VENEER WALL ABOVE ANY WALL FLASHING. E3 A320 F2 A319 B1 A320 E1 A320 E4 A320 E3 A318 B3 A320 E1 A318 D.6/3.1 15'-7 1/4" B/EP2.1 17'-6" 2ND FLR. 6'-4 5/8" T/COL BASE 1'-10" 1 1/2" 5/8" 8"4"9 1/4" 5/8"3"1'-1 3/4"1'-2 1/2"10 1/2"3 5/8"6 7/8"19'-1 1/2" T/EAVE 1'-11 3/8"1'-0"9 1/4"10"EIFS COLUMN 01 W/ CAST STONE BASE REFER TO COLUMN BASE DETAIL C1/A325 STEEL BM. REFER TO S-SERIES DWGS. PVC ROOF SYSTEM & INSULATION ON METAL DECK HEAT WELD PVC ROOF FLASH. TO ROOF MEMB & MEMB. ON EP2.1C EIFS CORNICE EP2.1 W/ PVC MEMBRANE OVER PLYWOOD W/ METAL DRIP EDGE 5/8" GLASS MATT CEILING W/ EXTERIOR FINISH W/ 3" PERIMETER VENT 3.2 C3 A318 1'-10"1 3/8"5/8"8"4"9 1/4"5/8"3 5/8"1'-6 1/2"9"17'-6"3 5/8"6 7/8"1'-5 3/8"2'-3 1/4" 3'-8 5/8"1'-2 1/2"10"5/8"18'-6 5/8" T/EAVE (FRAMING) 18'-3" B/FRAMING 1'-11 3/8"1'-0"9 1/4" 19'-1 1/2" T/EAVE (FRAMING) 17'-0 1/2" 16'-4 1/2" EIFS CORNICE PROFILE EP2.1 PVC ROOF SYSTEM & TAPERED INSUL. ON METAL DECK HEAT WELD PVC ROOF FLASHING ON PARAPET & EXTENDED 6" ON ROOF 5/8" GLASS MATT CEILING W/ EXTERIOR FINISH W/ 3" PERIMETER VENT CFS STUD WALL, 5/8" EXTERIOR SHEATHING ONE SIDE, PRESERVATIVE TREATED AND FIRE RETARDANT PVC MEMBRANE OVER FIRE RETARDENT TREATED PLYWOOD W/ METAL DRIP EDGE AND FASCIA PVC MEMBRANE WRAP UP FROM ROOF OVER SLAB, 1 COURSE CMU, TERMINATE UNDER FLASHING CORR. 100D SIM. B/CORNICE T/STL. 15'-7 1/4"2'-7 1/8"10 1/2"13 1'-2"1'-0"1'-7"1'-0" PVC ROOF SYSTEM & TAPERED INSUL. ON CONC. DECK W6Di PODIUM SLAB. REF. S-SERIES COM. 105 APT. 225 BRICK VENEER 5/8" GYPSUM BOARD 1" FOAM INSULATION THRU-WALL FLEXIBLE FLASHING W/ WEEP LAYER, TERMINATION BAR, PROPER CANTING AND S.S. DRIP EDGE. USE PROPER BRIDGING MATERIAL ACROSS AIRSPACE. LOOSE LAID STL. ANGLE VAPOR PERMEABLE AIR BARRIER DRIP EDGE TO COVER AND COUNTER ROOF TERMINATION GROUT SOLID BELOW FLASHING SCALE: 1:26.67 B1 Canopy Section Map A318SCALE: 1/8" = 1'-0" B3 West Low Roof Parapet - Framing Plan A318 0 4'8'16' SCALE: 3/4" = 1'-0" E1 Amenity Center Canopy Section A318 0 1'2'3' SCALE: 1 1/2"= 1'-0" E3 Section Detail A318 0 6''12''18'' SCALE: 1 1/2"= 1'-0" C3 Low Roof Section Detail A318 0 6''12''18''