Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A319 Wall Sections
Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateTHE CONCOURSECarmel, IN 46032550 Monon BlvdPEDCOR DESIGN GROUP LLC Wall Sections THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2023 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 02/03/2023 A 3 19 CITY REVIEW Revision ID Transmittal Set Date Transmittal Set Name 01 2/3/23 Carmel Review A B C D E 1 1 2 2 3 3 4 4 5 5 6 6 A B C D E F F NOT FORCONSTRUCTIONFriday, February 3, 2023, BIMcloud: pedcordesign - BIMcloud as a Service/Concourse/CONCOURSEA1 A322 D3 A319 B4 A323 NOTES: 1. PROVIDE MINERAL WOOL INSULATION (ROCKWOOL) INSIDE CFS BOX HEADERS AND CRIPPLE STUD CAVITIES SO ENTIRE WALL IS INSULATED. 2. PAINT ALL EXPOSED STEEL LINTELS WITH COLOR SPECIFIED BY ARCHITECT. 3. PROVIDE STAINLESS STEEL LINTELS WHERE SUPPORTING LIMESTONE. 4. FOR EIFS CORNICE PROFILES, SEE SHEETS A321, A322, AND A323 5. ALL STEEL AND ALUMINUM ON BALCONIES IS PAINTED W/ TNEMEC SYSTEM. 6. INSULATE THE CAVITIES IN STOREFRONT SYSTEMS BETWEEN FRAMES. SPRAY FOAM SHIM SPACES FOR AIR TIGHT SEALS. 7. REFER TO EIFS DETAILS FOR TYPICAL EIFS REQUIREMENTS AND OTHER REQUIREMENTS IMPLIED WHEN ADJOINING OTHER SYSTEMS. 8. WOOD BLOCKING AND PLYWOOD AT TYPE I CONSTRUCTION ARE FIRE RETARDANT TREATED, INCLUDING ANY WOOD ON THE LOW ROOF AND PARAPETS AT THE SECOND FLOOR, ALONG WITH CORRESPONDING COPING AND PARAPET DETAILS. 9. USE PRESERVATIVE TREATED EXTERIOR PLYWOOD SHEATHING AT ROOF SIDE OF PARAPETS AND PANELS AT ROOF WALLS, PORCH WALLS OR CANOPY AREAS. 10. PROVIDE AIR MOISTURE BARRIER PER MANUFACTURE’S REQUIREMENTS. DETAILS AT TRANSITIONS FROM WALLS, SLABS, LEDGES, FLASHINGS AND OPENINGS REQUIRE SPECIAL ATTENTION. COMMON DETAILS ARE SHOWN IN VARIOUS WALL SECTIONS DETAILS, WINDOW, DOOR AND STOREFRONT DETAILS, AND THE A500 SERIES. 11. SPACE IN EIFS CORNICE PROFILES INDICATES FRAMING DELEGATED FOR COORDINATION BETWEEN FRAMERS AND EIFS SUPPLIER. 12. PROVIDE MORTAR NET AT THE BASE OF EACH MASONRY VENEER WALL ABOVE ANY WALL FLASHING. 0.10.7B 3/4"1'-11 3/8"8"2 1/2" 18'-1 1/2" 20'-7 1/2"2'-7 3/8"3 5/8"6 1/8"1'-5 1/4"1'-2" 3/4"2'-7 1/4" 20'-9 5/8" B/FRAMING 21'-1 1/4" T/FRAMING EIFS CORNICE PROFILE EP2.1 W/ PVC MEMBRANE OVER PLYWOOD W/ METAL DRIP EDGE EIFS FINIAL 01 BEYOND REFER TO SIM DET. A3/A314 CFS STUD WALL, 5/8" EXTERIOR SHEATHING ONE SIDE, PRESERVATIVE TREATED AND FIRE RETARDANT PVC MEMBRANE OVER FIRE RETARDENT TREATED PLYWOOD W/ METAL DRIP EDGE AND FASCIA HEAT WELD PVC ROOF FLASH. TO ROOF MEMBRANE & MEMBRANE ON PARAPET CORNICE PVC ROOF SYSTEM & RECOVERY BOARD ON METAL DECK B/CORNICE TS/HP STEEL BEAM - SEE S- SERIES DRAWINGS WASH SLOPE ON EIFS TOP WASH SLOPE 3.2 15'-7 1/8" 17'-0 1/2" 20'-1 1/2" 20'-3 3/4" EIFS CORNICE PROFILE EP2.1 PVC ROOF SYSTEM &TAPERED INSUL. ON METAL DECK HEAT WELD PVC ROOF FLASHING ON PARAPET & EXTENDED 6" ON ROOF B/CORNICE T/STL T/FRAMING ROOF EDGE STEEL BEAM - SEE S- SERIES DRAWINGS CFS STUD WALL, 5/8" EXTERIOR SHEATHING ONE SIDE, PRESERVATIVE TREATED AND FIRE RETARDANT 5/8" GLASS MATT CEILING W/ EXTERIOR FINISH W/ 3" PERIMETER VENT METAL GUTTER CORNICE BEYOND WASH SLOPE ON EIFS TOP NOT TO SCALE F1 Perspective A319 SCALE: 1 1/2"= 1'-0" C5 Entrance Canopy Section Detail A319 0 6''12''18'' SCALE: 1 1/2"= 1'-0" D3 Entrance Canopy Gutter Section Detail A319 0 6''12''18'' 3.20.1 A1 A321 D3 A319 B4 A323 C5 A319 # A319 8 A510 +17'-6" 2 2nd Floor +28'-2" 3 3rd Floor +38'-10" 4 4th Floor +49'-6" 5 5th Floor 6'-10" T/COL BASE 18'-1 1/2" 20'-7 1/2" 21'-1 5/8" 15'-7 1/8" B/EP2.1B 15'-7 1/8" 20'-3 3/8" 17'-0 1/2"2'-0"2'-2"1'-11 3/8"10 1/2" EIFS CORNICE PROFILE EP6.1 W/ PVC MEMBRANE OVER PLYWOOD W/ METAL DRIP EDGE EIFS CORNICE PROFILE EP5.1 EIFS CORNICE PROFILE BP1.1 AT BALCONY EIFS CORNICE PROFILE EP2.1 B BRICK WATERTABLE SB3 3" CS COLUMN BASE EIFS COLUMN 01 W/ CAST STONE BASE EIFS COLUMN 02 W/ CAST STONE BASE BRICK WATERTABLE SB4 EIFS CORNICE PROFILE EP2.1 W/ PVC MEMBRANE OVER PLYWOOD W/ METAL DRIP EDGE TREX DECK OVER STEEL BALCONY FRAMING C.I.P. SLAB, BALCONY SLOPED TO DRAIN / LOW ROOF EIFS VENEER TREX DECK OVER STEEL BALCONY FRAMING TREX DECK OVER STEEL BALCONY FRAMING LOW ROOF EIFS WRAPPED ARCHITECTURAL WING WALL, BEYOND (RUNS 2ND-5TH FLR) METAL WRAP OVER EIFS AT SLOPED & RADIUS AREAS EIFS VENEER EIFS VENEER EIFS VENEER EIFS WRAPPED ARCHITECTURAL WING WALL, BEYOND (RUNS 2ND-5TH FLR) METAL RAILING LOW ROOF / CANOPY ASSEMBLY W/ EIFS CORNICE SKIRT BRICK VENEER ON STEEL LINTEL CONC. FOUNDATION, REF. S-SERIES DWGS. ALUMINUM STOREFRONT, REFERENCE ELEVATIONS AND A600 SERIES SHEETS WOOD STUD EXTERIOR WALL, REFERENCE S-SERIES FOR STRUCTURAL REQUIREMENTS. WINDOW- DOUBLE HUNG WINDOW- DOUBLE HUNG WINDOW- SINGLE HUNG CFS HEADER SINGLE COURSE CMU SIM. T/FRAMING B/CORNICE B/CORNICE T/STL T/FRAMING ROOF EDGE EIFS FINIAL 01 ON 36"X36" EIFS BASE W/ TREATED WOOD COLUMN SUPPORT. REFER TO DET. A3/A314. 5/8" GLASS MATT CEILING W/ EXTERIOR FINISH W/ 3" PERIMETER VENT STEEL BEAMS AND METAL DECK - SEE S-SERIES DRAWINGS EXTERIOR LIGHT FIXTURE MASONRY SIGN METAL GUTTER & DOWNSPOUT TAPERED INSULATION ROOF SCALE: 3/8" = 1'-0" F2 Wall Section A319 0 2'4'6'