Loading...
HomeMy WebLinkAboutA321 EIFS Cornice Profile Section Details EP6Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateTHE CONCOURSECarmel, IN 46032550 Monon BlvdPEDCOR DESIGN GROUP LLC EIFS Cornice Profile Section Details EP6 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2023 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 02/03/2023 A321 CITY REVIEW Revision ID Transmittal Set Date Transmittal Set Name 01 2/3/23 Carmel Review A B C D 1 1 2 2 3 3 4 4 A B C D NOT FORCONSTRUCTIONFriday, February 3, 2023, BIMcloud: pedcordesign - BIMcloud as a Service/Concourse/CONCOURSE2'-0"65'-3 1/4" 65'-6 3/8" REFER TO ELEVATION MIN.MTL. FASCIA & FLASHING STRIP HEAT WELDED TO ROOF MEMBRANE. REFER TO DETAIL A2/A505 PREFABRICATED PARAPET FRAMING & SHEATHING DESIGNED, FABRICATED, & INSTALLED BY A DELEGATED-DESIGN CONTRACTOR ROOF MEMBRANE ADHERED TO PARAPET SHEATHING LAPPED 4" OVER AND HEAT WELDED TO ROOF MEMBRANE FLASHING POLYVINYL CHLORIDE (PVC) ROOFING OVER 5/8" GYPSUM RECOVER BD., OVER INSUL. OVER 5/8" DENSGLAS SHEATING, OVER VAPOR BARRIER PRESERVATIVE EXTERIOR TREATED CONTINUOUS NAILERS POLYVINYL CHLORIDE (PVC) ROOF FLASHING 3/4" PRESERVATIVE EXTERIOR TREATED PLYWOOD SHEATHING PRESERVATIVE EXTERIOR TREATED BLOCKING EXTERIOR SHEATHING SYSTEM BACKER ROD & SEALANT PATTERNED EIFS PANEL PARAPET BATT INSULATION EXTENDS 2' MIN. ABOVE ROOF DECK T/PLY T/PLATE 5/8" GYP. BOARD BATT INSULATION PRE-APPLIED VAPOR BARRIER OR LIQUID APPLIED VAPOR PERMEABLE AIR BARRIER PAINTED WD. CASING PATIO DOOR WOOD HEADER INSULATION DOOR FRAME ZIP BOARD OR EXT. SHEATHING BRICK MOULD METAL DRIP FLASHING W/ WEEPS PER MANUFACTURER'S REQUIREMENTS EIFS TRIM ADHESIVE BACKED FLASHING BACKER ROD AND SEALANT 2'-2 1/8"9 7/8" 73'-4 1/2" MTL. FASCIA & FLASHING STRIP HEAT WELDED TO ROOF MEMBRANE. REFER TO DETAIL A2/A505 PREFABRICATED PARAPET FRAMING & SHEATHING DESIGNED, FABRICATED, & INSTALLED BY A DELEGATED-DESIGN CONTRACTOR ROOF MEMBRANE ADHERED TO PARAPET SHEATHING LAPPED 4" OVER AND HEAT WELDED TO ROOF MEMBRANE FLASHING EXTERIOR SHEATHING SYSTEM T/PLY EIFS DRIP EDGE 2'-0"65'-1" 65'-6 3/8" MTL. FASCIA & FLASHING STRIP HEAT WELDED TO ROOF MEMBRANE. REFER TO DETAIL A2/A505 PREFABRICATED PARAPET FRAMING & SHEATHING DESIGNED, FABRICATED, & INSTALLED BY A DELEGATED-DESIGN CONTRACTOR PRESERVATIVE EXTERIOR TREATED CONTINUOUS NAILERS 3/4" PRESERVATIVE EXTERIOR TREATED PLYWOOD SHEATHING PRESERVATIVE EXTERIOR TREATED BLOCKING BACKER ROD & SEALANT PATTERNED EIFS PANEL POLYVINYL CHLORIDE (PVC) ROOFING OVER 5/8" GYPSUM RECOVER BD., OVER INSUL. OVER 5/8" DENSGLAS SHEATHING, OVER VAPOR BARRIER PARAPET BATT INSULATION EXTENDS 2' ABOVE ROOF DECK TYP. T/PLATE T/PLY ROOF MEMBRANE ADHERED TO PARAPET SHEATHING LAPPED 4" OVER AND HEAT WELDED TO ROOF MEMBRANE FLASHING 3/8" EIFS DRIP EDGE 8 5/8"1'-7 1/2"11 1/2"9 1/8" 67'-9" 68'-2 3/8" 4"3"2" 9 1/4" MTL. FASCIA & FLASHING STRIP HEAT WELDED TO ROOF MEMBRANE. REFER TO DETAIL A2/A505 PREFABRICATED PARAPET FRAMING & SHEATHING DESIGNED, FABRICATED, & INSTALLED BY A DELEGATED-DESIGN CONTRACTOR ROOF MEMBRANE ADHERED TO PARAPET SHEATHING LAPPED 4" OVER AND HEAT WELDED TO ROOF MEMBRANE FLASHING POLYVINYL CHLORIDE (PVC) ROOFING OVER 5/8" GYPSUM RECOVER BD., OVER INSUL. OVER 5/8" DENSGLAS SHEATING, OVER VAPOR BARRIER PRESERVATIVE EXTERIOR TREATED CONTINUOUS NAILERS POLYVINYL CHLORIDE (PVC) ROOF FLASHING 3/4" PRESERVATIVE EXTERIOR TREATED PLYWOOD SHEATHING PRESERVATIVE EXTERIOR TREATED BLOCKING EXTERIOR SHEATHING SYSTEM DECORATIVE EIFS CAPITAL DECORATIVE PILASTER EXTEND BATT INSULATION ABOVE ROOF DECK 24" MIN. T/PLATE T/PLY BACK CUT PILASTER CAPITAL TO MATCH CORNICE PROFILE 3/8" EIFS DRIP EDGE 3/8" EIFS DRIP EDGE 1 2 2X8 WD BLOCKING W/ MTL COPING 3/8" EIFS DRIP EDGE BACKER ROD & SEALANT 1 2 2"1 1/2"1 1/2"5"4"4"4"3 1/2"3 1/2"3/8" EFIS DRIP EDGE BACKER ROD & SEALANT 2X WD BLOCKING MTL COPING 67'-9" 68'-2 3/8" MTL. FASCIA & FLASHING STRIP HEAT WELDED TO ROOF MEMBRANE. REFER TO DETAIL A2/A505 PREFABRICATED PARAPET FRAMING & SHEATHING DESIGNED, FABRICATED, & INSTALLED BY A DELEGATED-DESIGN CONTRACTOR ROOF MEMBRANE ADHERED TO PARAPET SHEATHING LAPPED 4" OVER AND HEAT WELDED TO ROOF MEMBRANE FLASHING POLYVINYL CHLORIDE (PVC) ROOF FLASHING 3/4" PRESERVATIVE EXTERIOR TREATED PLYWOOD SHEATHING PRESERVATIVE EXTERIOR TREATED BLOCKING DECORATIVE EIFS CAPITAL EXTEND BATT INSULATION ABOVE ROOF DECK 24" MIN. POLYVINYL CHLORIDE (PVC) ROOFING OVER 5/8" GYPSUM RECOVER BD., OVER INSUL. OVER 5/8" DENSGLAS SHEATING, OVER VAPOR BARRIER PRESERVATIVE EXTERIOR TREATED CONTINUOUS NAILERS T/PLY T/PLATE 3/8" EIFS DRIP EDGE 1 2 65'-4 3/8" 65'-6 3/8" MTL. FASCIA & FLASHING STRIP HEAT WELDED TO ROOF MEMBRANE. REFER TO DETAIL A2/A505 PREFABRICATED PARAPET FRAMING & SHEATHING DESIGNED, FABRICATED, & INSTALLED BY A DELEGATED-DESIGN CONTRACTOR POLYVINYL CHLORIDE (PVC) ROOFING OVER 5/8" GYPSUM RECOVER BD., OVER INSUL. OVER 5/8" DENSGLAS SHEATING, OVER VAPOR BARRIER PRESERVATIVE EXTERIOR TREATED CONTINUOUS NAILERS POLYVINYL CHLORIDE (PVC) ROOF FLASHING 3/4" PRESERVATIVE EXTERIOR TREATED PLYWOOD SHEATHING PRESERVATIVE EXTERIOR TREATED BLOCKING EXTEND BATT INSULATION ABOVE ROOF DECK 24" MIN. T/PLATE ROOF MEMBRANE ADHERED TO PARAPET SHEATHING LAPPED 4" OVER AND HEAT WELDED TO ROOF MEMBRANE FLASHING T/PLY 3/8" EIFS DRIP EDGE 1 2 NOTES: 1. PROVIDE MINERAL WOOL INSULATION (ROCKWOOL) INSIDE CFS BOX HEADERS AND CRIPPLE STUD CAVITIES SO ENTIRE WALL IS INSULATED. 2. PAINT ALL EXPOSED STEEL LINTELS WITH COLOR SPECIFIED BY ARCHITECT. 3. PROVIDE STAINLESS STEEL LINTELS WHERE SUPPORTING LIMESTONE. 4. FOR EIFS CORNICE PROFILES, SEE SHEETS A321, A322, AND A323 5. ALL STEEL AND ALUMINUM ON BALCONIES IS PAINTED W/ TNEMEC SYSTEM. 6. INSULATE THE CAVITIES IN STOREFRONT SYSTEMS BETWEEN FRAMES. SPRAY FOAM SHIM SPACES FOR AIR TIGHT SEALS. 7. REFER TO EIFS DETAILS FOR TYPICAL EIFS REQUIREMENTS AND OTHER REQUIREMENTS IMPLIED WHEN ADJOINING OTHER SYSTEMS. 8. WOOD BLOCKING AND PLYWOOD AT TYPE I CONSTRUCTION ARE FIRE RETARDANT TREATED, INCLUDING ANY WOOD ON THE LOW ROOF AND PARAPETS AT THE SECOND FLOOR, ALONG WITH CORRESPONDING COPING AND PARAPET DETAILS. 9. USE PRESERVATIVE TREATED EXTERIOR PLYWOOD SHEATHING AT ROOF SIDE OF PARAPETS AND PANELS AT ROOF WALLS, PORCH WALLS OR CANOPY AREAS. 10. PROVIDE AIR MOISTURE BARRIER PER MANUFACTURE’S REQUIREMENTS. DETAILS AT TRANSITIONS FROM WALLS, SLABS, LEDGES, FLASHINGS AND OPENINGS REQUIRE SPECIAL ATTENTION. COMMON DETAILS ARE SHOWN IN VARIOUS WALL SECTIONS DETAILS, WINDOW, DOOR AND STOREFRONT DETAILS, AND THE A500 SERIES. 11. SPACE IN EIFS CORNICE PROFILES INDICATES FRAMING DELEGATED FOR COORDINATION BETWEEN FRAMERS AND EIFS SUPPLIER. 12. PROVIDE MORTAR NET AT THE BASE OF EACH MASONRY VENEER WALL ABOVE ANY WALL FLASHING. SCALE: 1 1/2"= 1'-0" A1 EP6.1 A321 0 6''12''18'' SCALE: 1 1/2"= 1'-0" A4 EP6.10 A321 0 6''12''18'' SCALE: 1 1/2"= 1'-0" C3 EP6.6 A321 0 6''12''18'' SCALE: 1 1/2"= 1'-0" A3 EP6.8 A321 0 6''12''18'' SCALE: 1 1/2"= 1'-0" C2 EP6.3 A321 0 6''12''18'' SCALE: 1 1/2"= 1'-0" C1 EP6.2 A321 0 6''12''18'' SCALE: 1 1/2"= 1'-0" A2 EP6.7 A321 0 6''12''18'' SCALE: 1 1/2"= 1'-0" C4 EP6.11 A321 0 6''12''18''