Loading...
HomeMy WebLinkAboutA323 EIFS Cornice Profile Section Details - EP2Project: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateTHE CONCOURSECarmel, IN 46032550 Monon BlvdPEDCOR DESIGN GROUP LLC EIFS Cornice Profile Section Details - EP2 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2023 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 02/03/2023 A323 CITY REVIEW Revision ID Transmittal Set Date Transmittal Set Name 01 2/3/23 Carmel Review A B C D 1 1 2 2 3 3 4 4 A B C D NOT FORCONSTRUCTIONFriday, February 3, 2023, BIMcloud: pedcordesign - BIMcloud as a Service/Concourse/CONCOURSE1 1/2"1 3/8"1'-4 7/8"3 3/4"1"3 5/8"4 7/8"3 5/8"3 3/4"5 3/4"1'-11 3/8"4 1/4"2 5/8"6 1/4"8 5/8"1'-4 1/2"2 7/8" MTL. FASCIA & FLASHING STRIP HEAT WELDED TO ROOF MEMBRANE. REFER TO DETAIL A-5XX EXTERIOR SHEATHING COLORED EIFS ROOF MEMBRANE ADHERED TO STUD WALL SHEATHING LAPPED 4" OVER AND HEAT WELDED TO ROOF MEMBRANE FLASHING 3"2"3"1'-3"5"5"3 1/2"2 3/4"COLORED EIFS 2X6 WOOD STUD WALL W/ PLYWOOD SHEATHING SUPPORTING EIFS PROFILE PLYWOOD TRIM - NOT SURE WHAT'S GOING ON 16'-7 1/2" 17'-4 3/8" 19'-1"3'-4 1/2"6 5/8"1'-4 1/8"4 1/2"18'-8 9/16" EIFS PILASTER BASE DETAIL BUILT OVER WOOD FRAME BOX. PREFABRICATED FRAMING & SHEATHING DESIGNED, FABRICATED, & INSTALLED BY A DELEGATED DESIGN CONTRACTOR 9 1/4"5 1/2"9 1/8" 17'-4 3/8" B/EIFS ROOF MEMBRANE ADHERED TO PARAPET SHEATHING LAPPED 4" OVER AND HEAT WELDED TO ROOF MEMBRANE FLASHING SLOPED WOOD BLOCKING ON METAL STUD WALL BACKER ROD & SEALANT BRICK VENEER EIFS CORNICE PROFILE ATTACHED TO PARAPET WALL 1'-3 5/8"1'-1 5/8" EIFS CORNICE PROFILE EP2.2 W/ PVC MEMBRANE OVER PLYWOOD W/ METAL DRIP EDGE PREFABRICATED CORNICE FRAMING & SHEATHING DESIGNED, FABRICATED, & INSTALLED BY A DELEGATED-DESIGN CONTRACTOR DRIP EDGE IN EIFS TOP HALF OF EIFS DARK COLOR BACKER ROD & SEALANT BOTTOM HALF OF EIFS LIGHT COLOR BOTTOM OF EIFS LIGHT COLOR TOP OF EIFS DARK COLOR DRIP EDGE IN EIFS STUD FRAMING AND SHEATHING BEHIND EIFS METAL WALL CAP 8" CFS STUD WALL TOP OF EIFS DARK COLOR BOTTOM OF EIFS LIGHT COLOR MTL. FASCIA & FLASHING STRIP HEAT WELDED TO ROOF MEMBRANE. REFER TO DETAIL A-5XX PREFABRICATED CORNICE FRAMING & SHEATHING DESIGNED, FABRICATED, & INSTALLED BY A DELEGATED-DESIGN CONTRACTOR NOTES: 1. PROVIDE MINERAL WOOL INSULATION (ROCKWOOL) INSIDE CFS BOX HEADERS AND CRIPPLE STUD CAVITIES SO ENTIRE WALL IS INSULATED. 2. PAINT ALL EXPOSED STEEL LINTELS WITH COLOR SPECIFIED BY ARCHITECT. 3. PROVIDE STAINLESS STEEL LINTELS WHERE SUPPORTING LIMESTONE. 4. FOR EIFS CORNICE PROFILES, SEE SHEETS A321, A322, AND A323 5. ALL STEEL AND ALUMINUM ON BALCONIES IS PAINTED W/ TNEMEC SYSTEM. 6. INSULATE THE CAVITIES IN STOREFRONT SYSTEMS BETWEEN FRAMES. SPRAY FOAM SHIM SPACES FOR AIR TIGHT SEALS. 7. REFER TO EIFS DETAILS FOR TYPICAL EIFS REQUIREMENTS AND OTHER REQUIREMENTS IMPLIED WHEN ADJOINING OTHER SYSTEMS. 8. WOOD BLOCKING AND PLYWOOD AT TYPE I CONSTRUCTION ARE FIRE RETARDANT TREATED, INCLUDING ANY WOOD ON THE LOW ROOF AND PARAPETS AT THE SECOND FLOOR, ALONG WITH CORRESPONDING COPING AND PARAPET DETAILS. 9. USE PRESERVATIVE TREATED EXTERIOR PLYWOOD SHEATHING AT ROOF SIDE OF PARAPETS AND PANELS AT ROOF WALLS, PORCH WALLS OR CANOPY AREAS. 10. PROVIDE AIR MOISTURE BARRIER PER MANUFACTURE’S REQUIREMENTS. DETAILS AT TRANSITIONS FROM WALLS, SLABS, LEDGES, FLASHINGS AND OPENINGS REQUIRE SPECIAL ATTENTION. COMMON DETAILS ARE SHOWN IN VARIOUS WALL SECTIONS DETAILS, WINDOW, DOOR AND STOREFRONT DETAILS, AND THE A500 SERIES. 11. SPACE IN EIFS CORNICE PROFILES INDICATES FRAMING DELEGATED FOR COORDINATION BETWEEN FRAMERS AND EIFS SUPPLIER. 12. PROVIDE MORTAR NET AT THE BASE OF EACH MASONRY VENEER WALL ABOVE ANY WALL FLASHING. SCALE: 1 1/2"= 1'-0" A4 EP2.16 A323 0 6''12''18'' SCALE: 1 1/2"= 1'-0" A2 EP2.6 A323 0 6''12''18'' SCALE: 1 1/2"= 1'-0" B4 BP1.1 A323 0 6''12''18'' SCALE: 1 1/2"= 1'-0" B3 EP2.13 A323 0 6''12''18'' SCALE: 1 1/2"= 1'-0" D3 EP2.15 A323 0 6''12''18'' SCALE: 1 1/2"= 1'-0" A1 EP2.1 A323 0 6''12''18'' SCALE: 1 1/2"= 1'-0" B1 EP2.2 A323 0 6''12''18'' SCALE: 1 1/2"= 1'-0" B2 EP2.8 A323 0 6''12''18'' SCALE: 1 1/2"= 1'-0" C2 EP2.10 A323 0 6''12''18'' SCALE: 1 1/2"= 1'-0" D2 EP2.11 A323 0 6''12''18'' SCALE: 1 1/2"= 1'-0" A3 EP2.12 A323 0 6''12''18'' SCALE: 1 1/2"= 1'-0" C3 EP2.14 A323 0 6''12''18'' SCALE: 1 1/2"= 1'-0" C1 EP2.3 A323 0 6''12''18''