Loading...
HomeMy WebLinkAboutCT-008 CAMERA DETAILSProject: Developer: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: By: Sheet Title: COPYRIGHT & OWNERSHIP OF DOCUMENTS Architecture / Project Management: Project Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateTHE CONCOURSECarmel, IN 46032550 Monon BlvdPEDCOR DESIGN GROUP LLC CAMERA DETAILS THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2023 JAMES R. STUTZMAN, AIA, Carmel, Indiana. 02/03/2023 CT -008 CITY REVIEW Revision ID Transmittal Set Date Transmittal Set Name 01 2/3/23 Carmel Review A B C D 1 1 2 2 3 3 4 4 A B C D NOT FORCONSTRUCTIONFriday, February 3, 2023, BIMcloud: pedcordesign - BIMcloud as a Service/Concourse/CONCOURSEREFER TO APPENDIX MATERIALS.1 DRAWING FOR MORE INFORMATION ON PART NUMBERS REQUIRED PART NUMBERS NOTE 2RU WIRE MANAGER UPS 48 PORT ARUBA NETWORK SWITCH CORNING 2RU FIBER ENCLOSURE 1RU LEVITON 24 PORT PATCH PANEL CYBER POWER UPS 1500 KVA HOFFMAN EQUIPMENT CABINET LEVITON SURGE POWER STRIP PROVIDE GROUNDING KIT TO PROPERLY BOND TO BONDING BUSBAR CHECKED BY:REVISION DATE:KBSO NO:DRAWN BY:© Copyright, KBSO Consulting EngineersREF SHEET:SHEET TITLE:PROJECT:1344 S. Rangeling Road, Suite 202Carmel, IN 46032317.344.8044www.KBSOConsulting.com9/14/2022 11:46:04 AMTHE CONCOURSE - TYPICAL MDF EQUIPMENT CABINET ELEVATIONCITY OF CARMEL IT STANDARDSCON-APPENDIX CAB.121096EQUIPMENT CABINET REQUIREMENTS: 1. INSTALLATION A. Equipment racks and cabinets shall be securely attached to the concrete floors using manufacturer recommended hardware or as required by local codes. B. Bundle, lace, and train conductors and cables to terminal points without exceeding manufacturer's limitations on bending radii. Install lacing bars and distribution spools. C. All equipment cabinets and racks shall be grounded to the bonding busbar. D. All rack mounted equipment shall be installed in accordance with the manufacturer’s recommendations and installation guides. DATA CABLING REQUIREMENTS: 1. SUMMARY A. The Contractor shall provide, install, and test a complete communications copper horizontal cabling system that shall provide interconnections between MDF or IDF’s, and the telecommunications outlet. Cabling system consists of horizontal cables, intermediate and main cross-connects, mechanical terminations, patch panels, and patch cords or jumpers used for horizontal-to-horizontal cross-connection. B. The maximum allowable horizontal cable length is 295 feet. This maximum allowable length does not include an allowance for the length of 16 feet to the workstation equipment or in the horizontal cross-connect. 2. INSTALLATION A. The communications copper horizontal cabling system shall be installed in accordance with TIA standards-based recommendations, the manufacturer’s recommendations/installation guides, and industry best practices. B. All data cabling shall be installed in conduit.\ C. Provide a 3 foot service loop at each jack location and a 15 foot service loop for each cable in the MDF or IDF. All serivce loops shall be prorperly supported. D. Any cables that are damaged or exceeding the recommended installation parameters during installation shall be replaced by the installer at no cost to the owner. E. Identify system components, wiring, and cabling with labeling complying with the Owner. a. All labels shall be typed and printed. Handwritten labels will not be accepted. F. General installation requirements for cabling: a. Comply with TIA-568.1-D and TIA-568.2-D. b. Install 110-style IDC termination hardware unless otherwise indicated. c. Do not untwist twisted pair cables more than 1/2 inch from the point of termination to maintain cable geometry. d. Terminate all conductors; no cable shall contain unterminated elements. Make terminations only at indicated outlets, terminals, cross-connects, and patch panels. e. Cables may not be spliced. Secure and support cables at intervals not exceeding 30 inches and not more than 6 inches from cabinets, boxes, fittings, outlets, racks, frames, and terminals. f. Install lacing bars to restrain cables, prevent straining connections, and prevent bending cables to smaller radii than minimums recommended by manufacturer. g. Bundle and lace conductors to terminal points without exceeding manufacturer's limitations on bending radius, but not less than the radius specified in BICSI TDMM. Use lacing bars and distribution spools. h. Do not install bruised, kinked, scored, deformed, or abraded cable. Do not splice cable between termination, tap, or junction points. Remove and discard cable if damaged during installation and replace it with new cable. 3. TESTING A. Test each horizontal cable run, patch panel, and patch cable to verify the performance of the channel warranty for the horizontal cabling systems as defined in ANSI/TIA-1152-A. a. Each horizontal cable run shall be tested for length, continuity, insertion loss, return loss, PSNEXT, PSACR-N, and PSACR-F. b. All test results shall meet or exceed the latest ANSI/TIA-568-D series performance standards for the category of cabling tested. B. Record bandwidth for each test. C. Remove and replace cabling where test results indicate that they do not comply with specified requirements. 4. WARRANTY A. All components, parts, and assemblies of the Communications Copper Horizontal Cabling System supplied by the installer shall be guaranteed against defects in materials and workmanship for a period of 25 years by the manufacturer and installer. B. Warranties shall include all labor, material, travel expenses, test equipment, equipment rental and any other expense required to troubleshoot, remove, repair or replace equipment or components to bring the system up to the original performance criteria and operation. CONDUIT RUNS SHALL HAVE NO MORE THAN 180 DEGREES OF BENDS WITHOUT A PULL BOX. PROVIDE ADDITIONAL PULLBOX FOR EVERY 100 FEET OF CONDUIT PATH. CONDUIT PATHWAYS NOTE PROVIDE ONE (1) CATEGORY 6A CABLE FROM CAMERA TO NEAREST MDF OR IDF. PROVIDE 3 FOOT SERVICE LOOP. DATA CABLING LENGTH SHALL NOT EXCEED 300 FEET. WHERE CONDUIT IS ROUTED UNDERGROUND, PROVIDE OUTDOOR RATED CABLING. DATA CABLING NOTE REFER TO APPENDIX MATERIALS.1 DRAWING FOR MORE INFORMATION ON PART NUMBERS REQUIRED PART NUMBERS NOTE FINISHED FLOOR STRUCTURE REFER TO DRAWINGS FOR CAMERA NUMBER AXIS T94M01D PENDANT KIT AXIS T91B51 CEILING MOUNT CAMERA SHALL BE MOUNTED AT MAXIMUM PARKING GARAGE CLEARANCE 1" CONDUIT TO NEAREST MDF OR IDF. REFER TO CONDUIT ROUTING NOTES FOR MORE INFORMATION AXIS T91B52 EXTENSION PIPE (CUT TO SIZE) NOTE: PROVIDE CAMERA LICENSE FOR EACH CAMERA. COORDINATE EXACT LICENSE REQUIREMENTS WITH CITY OF CARMEL IT CHECKED BY:REVISION DATE:KBSO NO:DRAWN BY:© Copyright, KBSO Consulting EngineersREF SHEET:SHEET TITLE:PROJECT:1344 S. Rangeling Road, Suite 202Carmel, IN 46032317.344.8044www.KBSOConsulting.com9/14/2022 11:46:04 AMTHE CONCOURSE - OVERHEAD CAMERACITY OF CARMEL IT STANDARDSCON-APPENDIX CAM.121096CONDUIT RUNS SHALL HAVE NO MORE THAN 180 DEGREES OF BENDS WITHOUT A PULL BOX. PROVIDE ADDITIONAL PULLBOX FOR EVERY 100 FEET OF CONDUIT PATH. CONDUIT PATHWAYS NOTE PROVIDE ONE (1) CATEGORY 6A CABLE FROM CAMERA TO NEAREST MDF OR IDF. PROVIDE 3 FOOT SERVICE LOOP. DATA CABLING LENGTH SHALL NOT EXCEED 300 FEET. WHERE CONDUIT IS ROUTED UNDERGROUND, PROVIDE OUTDOOR RATED CABLING. DATA CABLING NOTE REFER TO APPENDIX MATERIALS.1 DRAWING FOR MORE INFORMATION ON PART NUMBERS REQUIRED PART NUMBERS NOTE FINISHED FLOOR REFER TO DRAWINGS FOR CAMERA NUMBER EXTERIOR WALL AXIS T91D61 WALL MOUNT 1" CONDUIT TO NEAREST MDF OR IDF. REFER TO CONDUIT ROUTING NOTES FOR MORE INFORMATION AXIS T94M01D PENDANT KIT 3.5" DEEP 2-GANG RECESSED DEVICE BOX WITH SINGLE GANG PLASTER RING MINIMUM 14'-0" A.F.F. NOTE: PROVIDE CAMERA LICENSE FOR EACH CAMERA. COORDINATE EXACT LICENSE REQUIREMENTS WITH CITY OF CARMEL IT CHECKED BY:REVISION DATE:KBSO NO:DRAWN BY:© Copyright, KBSO Consulting EngineersREF SHEET:SHEET TITLE:PROJECT:1344 S. Rangeling Road, Suite 202Carmel, IN 46032317.344.8044www.KBSOConsulting.com9/14/2022 11:46:05 AMTHE CONCOURSE - WALL MOUNTED CAMERA (RECESSED JUNCTIONBOX)CITY OF CARMEL IT STANDARDSCON-APPENDIX CAM.221096CONDUIT RUNS SHALL HAVE NO MORE THAN 180 DEGREES OF BENDS WITHOUT A PULL BOX. PROVIDE ADDITIONAL PULLBOX FOR EVERY 100 FEET OF CONDUIT PATH. CONDUIT PATHWAYS NOTE PROVIDE ONE (1) CATEGORY 6A CABLE FROM CAMERA TO NEAREST MDF OR IDF. PROVIDE 3 FOOT SERVICE LOOP. DATA CABLING LENGTH SHALL NOT EXCEED 300 FEET. WHERE CONDUIT IS ROUTED UNDERGROUND, PROVIDE OUTDOOR RATED CABLING. DATA CABLING NOTE REFER TO APPENDIX MATERIALS.1 DRAWING FOR MORE INFORMATION ON PART NUMBERS REQUIRED PART NUMBERS NOTE FINISHED FLOOR REFER TO DRAWINGS FOR CAMERA NUMBER AXIS T91D61 WALL MOUNT 1" CONDUIT TO NEAREST MDF OR IDF. REFER TO CONDUIT ROUTING NOTES FOR MORE INFORMATION AXIS T94M01D PENDANT KIT CAMERA SHALL BE MOUNTED AT MAXIMUM PARKING GARAGE CLEARANCE (WITH STRUCTURE ABOVE) OR MINIMUM 14'-0" A.F.F. (OPEN AIR) PROVIDE 3.5" DEEP 2-GANG SURFACE MOUNTED DEVICE BOX WITH COVER (WITH TAMPER PROOF SCREWS). NOTE: PROVIDE CAMERA LICENSE FOR EACH CAMERA. COORDINATE EXACT LICENSE REQUIREMENTS WITH CITY OF CARMEL IT CHECKED BY:REVISION DATE:KBSO NO:DRAWN BY:© Copyright, KBSO Consulting EngineersREF SHEET:SHEET TITLE:PROJECT:1344 S. Rangeling Road, Suite 202Carmel, IN 46032317.344.8044www.KBSOConsulting.com9/14/2022 11:46:05 AMTHE CONCOURSE - WALL MOUNTED CAMERA (SURFACE MOUNTEDJUNCTION BOX)CITY OF CARMEL IT STANDARDSCON-APPENDIX CAM.321096