HomeMy WebLinkAboutE-303 - ELECTRICAL ENLARGED PLANSTV
TV
TV
S
S
S
S
FF
FF
FJ
J
J
T
FF FFFF
S
TVTVTVS
S
S
J
J
J
TV
TV
TV FF
F
FF
S
S
S
S
J
J
J
T
F FFF
F
F
TV
TVTVS
SS
SJ
J
J
TV
FF
F
S
S
J
B5- 9
B5- 17,19
B5- 6
B5- 5
B5- 4 B5- 5
B5- 1,3
B5- 2 B5- 4
B5- 8
B5- 9
B5- 18,20
B5- 11
B5- 16
B5- 16 B5- 16
B5- 16
B5- 16
B5- 11
B5- 12
B5- 11
B5- 11
B5- 13
B5- 13
B5- 13B5- 13
B5- 13
B5- 11
B5- 14
B5
B5- 10
11
7
10
10
10
10
8
8
8
1
4
3
2
B5- 7
5 6
9
9
9
9
9
13
a b c
a
b
c
a
3b
c
3d
a
b b
c
c
d e
e e
e
f
g3d3e3fg
3b 3e3f
a
b
c
c
c
b
a
a
b
c
15'U8'
15'U4A'
15'U1'
15'U2'
15
'U6'
15'U1'15'U1'
15
'U5'
15
'U3'
15'U1'
15'U1'
15'U1'
15'U1'15'U1'
15'U1'
15'U3'
15'U1'
15'U4B'
a
c
aa
b
c
USB
USB +44"
USB
B5- 11
17
12
15
152' - 6"18
12
B5- 14
B5- 21
B5- 21
15'U8'a
14
19
22,24
FCU-1.5
20
20
15'U7'
15'U4A'B5- 21
B6
B6- 16
B6- 15
B6- 15B6- 16
B6- 16B6- 16
B6- 16
B6- 18
B6- 17
B6- 18
B6- 18 B6- 18
B6- 19
B6- 18
B6- 16
B6- 11
B6- 19
B6- 20,22
B6- 9
B6- 6 B6- 4 B6- 5
B6- 4
B6- 5
B6- 1,3
B6- 2
B6- 4
B6- 9
B6- 7
B6- 11
B6- 12,14B6- 11
B6- 13
B6- 15
B6- 15
B6- 15
B6- 15
9
9
9
9
9
2
10
10
10
10
8
8
8
1
4
11
5
6
3
B6- 10
7
a
b
c
c a
b
c
a
a
c
b
a b c
c
a
a
b
c
c
b
3a
3b
a
b
bb
b
c
cc
3a
3b
3d
dd
3d
e
f
g
e e
ee
g
f13
14
21'U2'
21'U1'21'U1'
21'U1'
21
'U3'
21'U3'
21'U5'
21'U1'
21
'U4A'
21'U4A'
21'U6'21'U1'
21'U4C'21'U1'
21'U1'21'U1'
21'U1'21'U1'
21'U1'
USB
USB +44"
USB
12
17
15
B6- 13
15
2' - 6"
B6- 19
12
18
a
21
'U8'
a
21'U8'
19
24,26
B6- 8
20
20
21'U7'
B7
B7- 14
B7- 16
B7- 14
B7- 14
B7- 14
B7- 14
B7- 14
B7- 15
B7- 15
B7- 17
B7- 17
B7- 17
B7- 17
B7- 18
B7- 18
B7- 18
B7- 18
B7- 7
B7- 9
B7- 7
B7- 10,12
B7- 19,21
B7- 13B7- 4B7- 2B7- 1,3B7- 5
B7- 4
B7- 5
B7- 6
B7- 18
B7- 20
7
8
8
8
3
11
9
9
9
9
9
10
10
10
10
56
1 4
2a
a
bcd
bb
d d
b
c
c
3d
3d
e f g
e e
ee
f
g
a c
c
a
b
c
c
a
b
b
a
c
c
a
a
b
c
c
a
b
b
11
'U1'
11
'U1'
11'U3'
11'U3'
11'U5'11'U6'
11
'U1'
11'U4B'
11'U1'
11'U1'11'U1'
11'U2'
11'U1'
11'U4A'
11
'U4A'
11
'U1'
11'U1'
11
'U1'
11
'U1'
11
'U1'
13
B7- 18
USB +44"
USB
USB
B7- 17
B7- 15
12
18
15
15
2' - 6"B7- 13
12
17
16
11'U8'
a
11'U8'
19
19
B7- 8
16
14
B7- 16
20
20
11'U7'
11'U7'
B8- 13
B8- 13
B8- 13
B8- 15
B8- 14,16
B8- 13
B8- 13
B8- 12
B8- 13 B8- 12
B8- 12
B8- 12
B8- 12
B8- 10
B8- 10
B8- 20,22
B8- 18
B8- 10
B8- 10
B8- 19
B8- 11
B8- 19
B8- 19
B8- 7
B8- 9B8- 7
B8- 4
B8- 2
B8- 1,3
B8- 5
B8- 4B8- 5B8- 6
10
10
1010
9
9
9
9
9
9
3
1
4
5
6
11
8
88
2
B8- 17
7
a b c
a
b
b
cc
3d
d
d
e
ee
e
f
g
h
a b c
c
abc
c
abc
c
a
b
abc
c
a
b
3h
3h 3e 3d
3eg
21'U2'
21'U1'
21'U4B'
21'U1'
21
'U1'
21'U6'21'U4B'
21'U1'
21'U1'
21
'U1'
21'U1'
21'U1'
21
'U3'
21
'U3'
21'U1'
21
'U1'21
'U5'
13
14
USB
USB
B8- 18
12
17
B8- 15
17
a
14
B8
15 15
2' - 6"
USB
21
'U8'
a
21
'U8'
19
23,25
B8- 8
3f
3f
20
20
21'U7'
D1- 13
D1- 15,17
D1
D1- 10D1- 10
D1- 10
D1- 2 D1- 4 D1- 1,3
D1- 4
D1- 5
D1- 7
D1- 6
D1- 9,11
D1- 7
D1- 7 D1- 7
D1- 7
D1- 8D1- 7
1
3
8
D1- 147
10
9
9
9
2
abc
ca
fgh
h
12'U6'
f,g
a a b b
bb
b c d
d
12'U4B'
12'U1'
12'U1'
12'U1'
12'U1'
12
'U1'
12'U1'
b
12'U1'
a12'U1'
12'U9'
USB
USB
+42"
D1- 16
16
D1- 13
12
17
5
6
19
18,20
12'U7'
a
A. SEE SHEET E-000 FOR SYMBOLS AND ABBREVIATIONS.
B. SEE SHEET E-502 FOR MECHANICAL EQUIPMENT POWER SCHEDULE.
C. SEE SHEETS E-503 THROUGH E-505 FOR PANEL SCHEDULES.
D. SEE SHEETS E-601 FOR ELECTRICAL DETAILS.
E. WIRING SYSTEM SHALL BE CONDUIT AND CONDUCTOR UNLESS NOTED
OTHERWISE. USE SOLID CONDUCTOR FOR SIZE #10 AWG AND SMALLER.
USE STRANDED CONDUCTOR FOR LARGER SIZES.
F. ALL COVER PLATES FOR ELECTRICAL DEVICES SHALL BE OF A COLOR TO
MATCH THE AREA COLOR SCHEME AS DIRECTED BY THE INTERIOR
DESIGNER.
G. ALL WORK SHALL COMPLY WITH ALL NATIONAL, STATE AND LOCAL CODES
AND ORDINANCES PERTAINING TO THE WORK IN THIS PROJECT.
H. EXPOSED CONDUIT SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO
BUILDING LINES.
I. REFER TO ARCHITECTURAL DRAWINGS FOR DESIGNATION AND LISTING OF
FIRE RATED ASSEMBLIES. COORDINATE ALL DESIGN EFFORTS WITH FIRE
RESISTANCE OF MATERIALS AND CONSTRUCTION.
J. ALL EXTERIOR EQUIPMENT AND DEVICES SHALL BE WEATHER PROOF AND
RAIN TIGHT.
K. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL
INTERCONNECT WIRING FOR MECHANICAL AND PLUMBING EQUIPMENT
FURNISHED BY OTHERS.
GENERAL SHEET NOTES
RCP DIMENSIONING NOTE
ALL ELECTRICAL EQUIPMENT AND DEVICES LOCATED IN THE CEILING MUST BE
COORDINATED WITH THE UNDERLYING STRUCTURAL FRAMING SYSTEM. EC TO
PREPARE AND SUBMIT COORDINATION DRAWINGS ALONG WITH SHOP DRAWINGS PRIOR
TO ROUGH-IN THAT PROVIDE A COMPLETE REFLECTED CEILING PLAN WITH ALL CEILING
MOUNTED DEVICES, EQUIPMENT AND FIXTURES INDICATED AND DIMENSIONED AT
MINIMUM OF 1/2" = 1'-0" SCALE. SUBMITTAL IS FOR THE REVIEW AND APPROVAL OF THE
ARCHITECT/INTERIOR DESIGNER AND MEP ENGINEER.
21071
Project:
Developer:
Sheet Number:
Engineer:
By:
Sheet Title:
CDG Number:
Last Revision Date:
Set Issue Date
Drawn By Checked By
Sheet Issue DateTHE CONCOURSECarmel, IN 46032Carmel Review
GRJK550 Monon BlvdNOT FOR CONSTRUCTIONE-303
ELECTRICAL
ENLARGED PLANS
02/03/202302/03/2023
0 8'4'2'0 8'4'2'
0 8'4'2'0 8'4'2'0 8'4'2'
1/4" = 1'-0"
UNIT B5 ELECTRICAL ENLARGED PLAN1 1/4" = 1'-0"
UNIT B6 ELECTRICAL ENLARGED PLAN2
1/4" = 1'-0"
UNIT B7 ELECTRICAL ENLARGED PLAN3 1/4" = 1'-0"
UNIT B8 ELECTRICAL ENLARGED PLAN4 1/4" = 1'-0"
UNIT D1 ELECTRICAL ENLARGED PLAN5
SHEET PLAN NOTES
1 RANGE: INSTALL NEMA 14-50R FLUSH MOUNTED RECEPACE AT +24" AFF.
BRANCH WIRING TO BE 3-#6 AND 1-#10 GRD COPPER CONDUCTORS.
2 DRYER: INSTALL NEMA 14-30R FLUSH RECEPTACLE AT +36" AFF. BRANC
WIRING TO BE 3-#10 AND 1-#10GRD COPPER CONDUCTORS.
3 WATER HEATER: BRANCH WIRING TO BE 3-#10 AND 1-#10 GRD COPPER
CONDUCTORS. CONNECT CIRCUIT TO WATER HEATER THROUGH
DISCONNECT SWITCH INSTALLED ADJACENT TO WATER HEATER. INSTALL
DISCONNECT SWITCH TO ALLOW FOR MINIMUM CODE REQUIRED WORKING
CLEARANCE.
4 MICROWAVE: ROUGH-IN FOR WALL MOUNTED MIRCROWAV/HOOD UNIT.
INSTALL ROUGH-IN AT +64" AFF UNLESS OTHERWISE NOTED. INSTALL
ELECTRICAL ROUGH-IN AND WIRING PER THE REQUIREMENTS PROVIDED
WITH THE MANUFACTURER'S INSTALLATION MANUAL.
5 GARBAGE DISPOSAL: SPLIT WIRED DUPLEX RECEPTACLE INSIDE LOWER SINK
CABINET. TOP HALF OF DUPLEX FOR DISPOSAL CONTROLLED BY DISPOSAL
SWITCH LOCATED BELOW SINK.
6 DISHWASHER: CONNECT DISWASHER WITH CORD AND PLUG TO THE
UNSWITCHED LOWER HALF OF SPLIT DUPLEX RECEPTALCE.
7 TELECOM: TELECOMMUNICATIONS HOME NETWORKING FLUSH MOUNTED
CABINET. PROVIDE RECEPTACLE INSIDE THE CABINETENCLOSURE. VERIFY
EXACT LOCATION WITH THE OWNER AND THE OWNER'S LOW VOLTAGE
CONSULTANT PRIOR TO ROUGH-IN.
8 TELEVISION: PROVIDE ONE DUPLEX RECEPTACLE AND ONE WIRED "F" TYPE
TV JACK WITH ONE RG-6 COAX CABLE FROM THIS OUTLET TO THEHOME
NETWORKING ENCLOSURE CABINT.
9 FIRE ALARM: IN ADAPTABLE (TYPE B) UNITS - JUNCTION BOX, WIRING AND
BLANK COVER PLATE FOR FUTURE ADDRESSABLE ADA FIRE ALARM STROBE,
IN ADA (TYPE A) UNITS- PROVIDE STROBE INSTALLED.
10 FIRE ALARM: PROVIDE SYSTEM DETECTOR WITH AUDIBLE SOUNDER BASE
MEETING NFPA 72 CODE REQUIEMENT FOR LOW-FREQUENCY, 520 HZ TONE.
11 ISLAND RECEPT: PROVIDE USB/USBC ENABLED GFCI RECEPTACLE LOCATED
NO MORE THAN 12" BELOW TOP EDGE OF COUNTERTOP TO BOTTOM OF
OUTLET FACEPLATE.
12 EXHAUST FAN: CONNECT EXHAUST FAN TO SWTCH ON WALL.
13 CEILING FAN: CEILING MOUNTED JUNCTION BOX FOR FUTURE FAN. PROVIDE
COVERPLATE.
14 CEILING FAN: PROVIDE BLACKBOX AND COVER PLATE FOR FUTURE FAN
CONTROL CORDINATE WITH LTG AS TO WHERE FUTURE FANS GO.
15 ISLAND LTG: ALIGN PENDANTS OVER ISLAND AND PENINSULA WITH FACE OF
LOW SUPPORTING WALL ON LIVING ROOM SIDE. SPACE PENDANTS AS
INDICATED WITH AN EQUAL DISTANCE FROM THE EDGE(S) OF COUNTERTOP.
COORDINATE EXACT LOCATIONS AND SPACING WITH ARCHITECT & INTERIOR
DESIGNER PRIOR TO ROUGH IN.
16 PROVIDE AND INSTALL 2-GANG COMBINATION ROCKER SWITCH FOR MIRROR
LIGHTING AND GFCI RECEPTACLE.
17 ALIGN EDGE OF LIT MIRROR WITH FINISHED END OF SINK BASE CABINET AND
COUNTERTOP. REFER TO ARCHITECTURAL ELEVATIONS ON SHEETS A423
THROUGH A427 FOR EXACT PLACEMENT OF LED MIRROR.
18 CENTER EACH LIT MIRROR OVER EACH SINK BOWL. REFER TO
ARCHITECTURAL ELEVATIONS ON SHEETS A423 THROUGH A427 FOR EXACT
PLACEMENT OF LED MIRROR.
19 SWITCH FOR EXTERIOR BALCONY LIGHT FIXTURE TYPE 'U7'. REFER TO
LIGHTING PLANS AND ARCHITECTURAL ELEVATIONS FOR EXACT LOCATION.
20 CEILING FAN: PROVIDE WIRING FOR FUTURE FAN AND TWO SWITCHES, ONE
FOR FAN AND ONE FOR FAN LIGHT. INSTALL BLANK COVERPLATE WHERE NO
LIGHT FIXTURE IS INITALLY INSTALLED.