HomeMy WebLinkAboutE-401 - ELECTRICAL RISER DIAGRAMTRANSFORMER #2 M 125A-2P M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M 400A-3P M 200A-3P M 200A-3P M 200A-3P M 200A-3P PANEL C1 120/208 3P, 4W 400A MLO PANEL C2 120/208 3P, 4W 200A MLO PANEL C3 120/208 3P, 4W 200A MLO PANEL C4 120/208 3P, 4W 200A MLO PANEL C5 120/208 3P, 4W 200A MLO M 400A-3P M 200A-3P M 200A-3P M 200A-3P PANEL C6 120/208 3P, 4W 400A MLO PANEL C7 120/208 3P, 4W 200A MLO PANEL C9 120/208 3P, 4W 200A MLO PANEL C11 120/208 3P, 4W 200A MLO COMMERCIAL 1 COMMERCIAL 2 COMMERCIAL 3 COMMERCIAL 4 COMMERCIAL 5 COMMERCIAL 6 COMMERCIAL 7 COMMERCIAL 9 COMMERCIAL 11 PANEL C8 120/208 3P, 4W 400A MLO HOUSE 2 CT CABINET 800A PANEL C10 120/208 3P, 4W 400A MLO HOUSE 1 CT CABIENT 800A TRANSFORMER #1 1000A MAIN CIRCUIT BREAKER 120/208V 3P-4W 65K AIC M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M 1000-3N 1000-3N 1200-3N 800-3N 800-3N 1200-3N 800-3NG 800-3NG M 400A-3P COMMERCIAL 8 PANEL H1A 120/208 3P, 4W 800A MLO PANEL H2A 120/208 3P, 4W 800A MLO UTILITY UTILITY 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P 125A-2P TYPICAL 2/0-2/0-2/0-1 ALUMINUM SER CABLE TO CABLE TO EACH APARTMENT PANL. INCREASE WIRE SIZE TO KEEP VOLTAGE DROP BELOW 2% FOR FEEDERS OVER 100'-0" IN LENGTH. TYPICAL 2/0-2/0-2/0-1 ALUMINUM SER CABLE TO CABLE TO EACH APARTMENT PANL. INCREASE WIRE SIZE TO KEEP VOLTAGE DROP BELOW 2% FOR FEEDERS OVER 100'-0" IN LENGTH. TYPICAL 2/0-2/0-2/0-1 ALUMINUM SER CABLE TO CABLE TO EACH APARTMENT PANL. INCREASE WIRE SIZE TO KEEP VOLTAGE DROP BELOW 2% FOR FEEDERS OVER 100'-0" IN LENGTH. TYPICAL 2/0-2/0-2/0-1 ALUMINUM SER CABLE TO CABLE TO EACH APARTMENT PANL. INCREASE WIRE SIZE TO KEEP VOLTAGE DROP BELOW 2% FOR FEEDERS OVER 100'-0" IN LENGTH. SOUTH SOUTH 1200A MAIN CIRCUIT BREAKER 120/208V 3P-4W 65K AIC 1000A MAIN CIRCUIT BREAKER 120/208V 3P-4W 65K AIC 1200A MAIN CIRCUIT BREAKER 120/208V 3P-4W 65K AIC PV SYSTEM M M M 125A-2P 125A-2P 125A-2P M 125A-2P M 125A-2P M M M M 125A-2P 125A-2P 125A-2P 125A-2P M 125A-2P M M M 125A-2P 125A-2P 125A-2P UTILITY TRANSFORMER NOTES OWNERS NAME:THE CONCOURSE CONTACT #:(???)???-???? ADDRESS:?????EXST SRVC METER #: ????? CITY, STATE ZIP CODE NEW SRVC METER #: ????? UTILITY SERVICE PROVIDER:DUKE CONTACT NAME: BILL FERRELL CONTACT #: (317)776-5351 EMAIL:Bill.Ferrell@duke-energy.com MOUNTING TYPE:PAD FEED TYPE: UNDERGROUND POWER RATING:500 KVA PRIMARY SECONDARY CONFIGURATION:DELTA CONFIGURATION:WYE VOLTAGE: MEDIUM VOLTAGE: 208V UTILITY RESPONSIBILITIES CONTRACTOR RESPONSIBILITIES PRIMARY CONDUCTORS, INSTALLATION & TERMINATION OF SECONDARY CABLES AT TRANSFORMER, METER BOX/CT CABINET ORDER INSTALLATION/COORDINATE WITH UTILITY INSTALLATION MUST COMPLY WITH UTILITY STANDARDS/REQUIREMENTS PRIMARY CONDUITS & INSTALLATION SECONDARY CONDUITS, FEEDERS, INSTALLATION & TERMINATION AT MDP OR MSWBD METER BOX/CT CABINET INSTALLATION TRANSFORMER PAD INSTALLATION UTILITY TRANSFORMER NOTES OWNERS NAME: THE CONCOURSE CONTACT #: (???)???-???? ADDRESS: ????? EXST SRVC METER #: ????? CITY, STATE ZIP CODE NEW SRVC METER #: ????? UTILITY SERVICE PROVIDER: DUKE CONTACT NAME: BILL FERRELL CONTACT #: (317)776-5351 EMAIL:Bill.Ferrell@duke-energy.com MOUNTING TYPE:PAD FEED TYPE: UNDERGROUND POWER RATING: 750 KVA PRIMARY SECONDARY CONFIGURATION: DELTA CONFIGURATION:WYE VOLTAGE: MEDIUM VOLTAGE: 208V UTILITY RESPONSIBILITIES CONTRACTOR RESPONSIBILITIES PRIMARY CONDUCTORS, INSTALLATION & TERMINATION OF SECONDARY CABLES AT TRANSFORMER, METER BOX/CT CABINET ORDER INSTALLATION/COORDINATE WITH UTILITY INSTALLATION MUST COMPLY WITH UTILITY STANDARDS/REQUIREMENTS PRIMARY CONDUITS & INSTALLATION SECONDARY CONDUITS, FEEDERS, INSTALLATION & TERMINATION AT MDP OR MSWBD METER BOX/CT CABINET INSTALLATION TRANSFORMER PAD INSTALLATION M 125A-2P MUSEUM 150KVA XFMR 'T1' 150KVA XFMR 'T2' SERV. ELEV. 1 PUB. ELEV. 3 PUB. ELEV. 2PUB. ELEV. 1 PANEL E1 480/277 3P, 4W 100A MLO PANEL E2 480/277 3P, 4W 100A MLO M 400A-3P COMMERCIAL 10 100-3NG 100-3NG 200-3NG 200-3NG 50-3NG PANEL H1B 120/208 3P, 4W 100A MLO PANEL H2B 120/208 3P, 4W 100A MLO 200-3NG 200-3NG FEEDER SCHEDULE NOMINAL OCP AMPS 20-# 30-# 40-# COPPER FEEDERS AND COPPER GROUND GROUND SETS 1 1 1 CONDUCTOR AMPACITY 20A 30A 40A COPPER WIRE SIZE #12 #10 #8 CONDUCTOR PER CONDUIT COPPER WIRE #12 #10 #10 MINIMUM CONDUIT SIZE 3/4" 3/4" 3/4" ALUMINUM FEEDERS AND COPPER GROUND GROUND SETS CONDUCTOR AMPACITY ALUMINUM WIRE SIZE CONDUCTOR PER CONDUIT COPPER WIRE MINIMUM CONDUIT SIZE 60-# 70-# 80-# 1 1 1 55A 70A 80A #6 #4 #3 #10 #8 #8 1" 1 1/4" 1 1/4" 100-# 130-# 150-# 175-# 200-# 225-# 250-# 300-# 350-# 400-# 500-# 600-# 800-# 1000-# 1200-# 1600-# 2000-# 2500-# 3000-# 1 1 1 1 1 1 1 1 1 1 2 2 2 3 4 5 6 7 8 95A 130A 150A 175A 200A 230A 255A 310A 350A 380A 510A 620A 760A 1140A 1240A 1900A 2300A 2660A 3040A #2 #1 #1/0 #2/0 #3/0 #4/0 250 KCMIL 350 KCMIL 500 KCMIL 500 KCMIL 250 KCMIL 350 KCMIL 500 KCMIL 500 KCMIL 350 KCMIL 500 KCMIL 500 KCMIL 500 KCMIL 500 KCMIL #8 #6 #6 #6 #6 #4 #4 #4 #3 #2 #2 #1 #1/0 #2/0 #3/0 #4/0 250 KCMIL 350 KCMIL 400 KCMIL 1 1/4" 1 1/2" 2" 2" 2" 2 1/2" 2 1/2" 3" 3" 3 1/2" 3" 3" 3 1/2" 3 1/2" 3" 3 1/2" 3 1/2" 4" 4" 1 1 1 1 1 1 1 1 1 2 2 2 3 4 5 6 7 8 135A 155A 180A 205A 230A 270A 310A 350A 385A 500A 620A 770A 1155A 1240A 1925A 2310A 2695A 3080A #2/0 #3/0 #4/0 300 KCMIL 250 KCMIL 400 KCMIL 500 KCMIL 750 KCMIL 750 KCMIL 350 KCMIL 500 KCMIL 750 KCMIL 750 KCMIL 500 KCMIL 750 KCMIL 750 KCMIL 750 KCMIL 750 KCMIL #6 #6 #6 #6 #4 #4 #4 #3 #3 #2 #1 #1/0 #2/0 #3/0 #4/0 250 KCMIL 350 KCMIL 400 KCMIL 2" 2" 2" 2" 2" 2 1/2" 3" 3" 4" 3" 3 1/2" 4" 4" 3 1/2" 4" 4" 4" 4" -- - - - - - - - - - NOTES: 1. WIRING SHALL BE PROVIDED IN ACCORDANCE WITH NEC, UNLESS LARGER SIZES ARE SHOWN TO ACCOMMODATE FUTURE LOADS OR VOLTAGE DROP. 2. THE NUMBER OF PHASE WIRES ARE DESIGNATED BY '#' IN SCHEDULE. REFER TO RISER DIAGRAM FOR EXACT AMOUNT. 3. PROVIDE AN EQUIPMENT GROUNDING CONDUCTOR IN EVERY FEEDER AND BRANCH CIRCUIT. 4. BASED ON THWN/THHN COPPER CONDUCTORS IN 30C AMBIENT. 5. DO NOT USE THIS TABLE FOR SCHEDULE 80 PVC OR ENT (WHEN PERMITTED BY SPECIFICATIONS), REFER TO NEC CHAPTER 9. 6. KEY: AMPREAGE - PHASE/NEUTRAL/GROUND. EXAMPLE "300-3NG = 300 AMP FEEDER, 3 PHASE, 4 WIRE WITH GROUND", "90-3G = 90 AMP FEEDER, 3 PHASE, 3 WIRE WITH GROUND". 7. ALUMINUM NOT UTILIZED BELOW 100 AMPS DUE TO ISSUES CONCERNS WITH EQUIPMENT SUPPLIES AND LUG COMPATABILITY ISSUES. 21071 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateTHE CONCOURSECarmel, IN 46032Carmel Review GRJK550 Monon BlvdNOT FOR CONSTRUCTIONE-401 ELECTRICAL RISER DIAGRAM 02/03/202302/03/2023 NOT TO SCALE E-RISER DIAGRAM1 EC SHALL PROVIDE PROPOSED ROUTING OF SERVICE AND APARTMENT FEEDERS FOR ARCHITECTURAL AND ENGINEERING REVIEW PRIOR TO INSTALLATION. FEEDER ROUTING NOTE