Loading...
HomeMy WebLinkAboutEL103A - 3RD FLOOR LIGHTING PLAN - AREA AM P M P M P M P M PMM P M P M P M P MGA GB GC G8 GE GJ 12 F K M 14 N 16 15 L.5L.1J.1 18 D.8D.3CD.1BA0.8A A.3 13 13.8 GFG.9A GA.9 G7.9 13.9 H2B - 3 'L4' H2B - 3 'L4' H2B - 3 'L4' H2B - 3 'L4' H2B - 3 'L4' H2B - 3 'L1' H2B - 3 'L1' H2B - 3 'L1' H2B - 3 'L1' H2B - 3 'L4' H2B - 3 'L1' H2B - 3 'L1'H2B - 3 'L1' H2B - 3 'L1' H2B - 3 'L1'H2B - 3 'L1' H2B - 3 'L1' H2B - 3 'L5' H2B - 3 'L5' H2B - 3 'L1' H2B - 3 'L1'H2B - 3 'L4' H2B - 3 'L4' H2B - 3 'L4' H2B - 3 'L4'H2B - 3 'L4' H2B - 3 'L4' H2B - 3 'L1' 1 11 1 1 H2B - 3 'L1' H2B - 3 'L1' H2B - 3 'L1' H2B - 3 'L1' H2B - 3 'L4' H2B - 3 'L1' 'U7' 'U7' 'U7''U7''U7''U7' 'U7' 'U7''U7' APARTMENT TYPE A1 SEE ENLARGED ELECTRICAL PLANS APARTMENT TYPE B2 SEE ENLARGED ELECTRICAL PLANS APARTMENT TYPE B1 SEE ENLARGED ELECTRICAL PLANS APARTMENT TYPE D1 SEE ENLARGED ELECTRICAL PLANS APARTMENT TYPE A2 SEE ENLARGED ELECTRICAL PLANS APARTMENT TYPE A2 SEE ENLARGED ELECTRICAL PLANS APARTMENT TYPE D1 SEE ENLARGED ELECTRICAL PLANS APARTMENT TYPE B9 SEE ENLARGED ELECTRICAL PLANS APARTMENT TYPE A1 SEE ENLARGED ELECTRICAL PLANS APARTMENT TYPE B2 SEE ENLARGED ELECTRICAL PLANS APARTMENT TYPE B4 SEE ENLARGED ELECTRICAL PLANS 'U7' 'U7' NLNL NL NL NLNL NLNL NL NL NL NL NL H2B - 3 'X1' H2B - 3 'X1' H2B - 3 'X2' H2B - 3 'X1' H2B - 3 'X1' H2B - 3 'EM1' H2B - 3 'EM1' H2B - 3 'EM1' H2B - 3 'EM1' H2B - 3 'EM1' H2B - 3 'EM1' H2B - 3 'EM1' H2B - 3 'K2' H2B - 3 'K2' H2B - 3 'K2' H2B - 3 'L13' H2B - 3 'K2' H2B - 3 'K2' H2B - 3 'K2' H2B - 3 'X1' H2B - 3 'L1' H2B - 3 'L1' H2B - 3 'L1' H2B - 3 'L1' NL APARTMENT TYPE A3 SEE ENLARGED ELECTRICAL PLANS 'U7' APARTMENT TYPE B9 SEE ENLARGED ELECTRICAL PLANS H2B - 3 'X1' H2B - 3 'L1' GENERAL SHEET NOTES A. SEE SHEET E-001 FOR SYMBOLS AND ABBREVIATIONS. B. SEE SHEET E-501 FOR LIGHTING FIXTURE SCHEDULE AND LIGHTING CONTROL SEQUENCE SCHEDULE. C. SEE E-500 SERIES SHEETS FOR PANEL SCHEDULES. D. SEE E-600 SERIES SHEETS FOR ELECTRICAL DETAILS. E. SEE E-300 SERIES FOR ENLARGED UNIT PLANS. F. COORDINATE INSTALLATION OF LIGHTING FIXTURES WITH ARCHITECTURAL REFLECTED CEILING PLANS, ARCHITECTURAL ELEVATIONS, MECHANICAL EQUIPMENT, DIFFUSERS, SUPPORTS, PIPING, DUCTWORK AND STRUCTURAL PLANS PRIOR TO ROUGH-IN AND INSTALLATION OF LIGHTS. G. ALL MOUNTING HEIGHTS NOTED ON THE PLANS ARE TO THE BOTTOM OF THE FIXTURES UNLESS NOTED OTHERWISE. H. LOCATE CEILING MOUNTED OCCUPANCY SENSORS TO PROVIDE COMPLETE AREA COVERAGE OF THE SPACE THEY ARE INSTALLED IN. SELECT PROPER SENSOR COVERAGE PATTERN FROM MANUFACTURER'S PRODUCT DATA TO DETERMINE COVERAGE. ADDITIONAL SENSORS REQUIRED DUE TO LACK OF COVERAGE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND THE MANUFACTURER. SENSORS SHALL INCLUDE ALL POWER SUPPLIES AND RELAYS NECESSARY FOR PROPER OPERATION. I. WIRING SYSTEM SHALL BE CONDUIT AND CONDUCTOR UNLESS NOTED OTHERWISE. USE SOLID CONDUCTOR FOR SIZE #10 AWG AND SMALLER. USE STRANDED CONDUCTOR FOR LARGER SIZES. J. ALL COVER PLATES FOR ELECTRICAL DEVICES SHALL BE OF A COLOR TO MATCH THE AREA COLOR SCHEME AS DIRECTED BY THE INTERIOR DESIGNER. K. LABEL ALL RELAYS AND POWER SUPPLIES (ON THE DEVICE OR ON THE BOX THEY ARE CONNECTED TO) WITH THE AREA THE DEVICES SERVES, THE BRANCH CIRCUIT IT CONTROLS AND THE DEVICE ADDRESS (IF APPLICABLE). L. EMERGENCY LIGHTING SHOWN ON THIS DRAWING INDICATES CODE REQUIRED EMERGENCY LIGHTING. M. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS, ROOM AND AREA FINISHES, CEILING PLANS, DOOR SWINGS, FIRE-RATED PARTITIONS, CABINET AND CASEWORK AND BUILT-IN DETAILS. N. ALL WORK SHALL COMPLY WITH ALL NATIONAL, STATE AND LOCAL CODES AND ORDINANCES PERTAINING TO THE WORK IN THIS PROJECT. O. EXPOSED CONDUIT SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO BUILDING LINES. P. REFER TO ARCHITECTURAL DRAWINGS FOR DESIGNATION AND LISTING OF FIRE RATED ASSEMBLIES. COORDINATE ALL DESIGN EFFORTS WITH FIRE RESISTANCE OF MATERIALS AND CONSTRUCTION. Q. ALL EXTERIOR EQUIPMENT AND DEVICES SHALL BE WEATHER PROOF AND RAIN TIGHT. R. REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR MOUNTING HEIGHT OF WALL MOUNTED FIXTURE TYPES 'L4', 'L5', 'W1', 'W2', 'W3' AND 'W4'. S. REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR MOUNTING HEIGHT OF SUSPENDED FIXTURE TYPES 'L6', 'L7', 'L10', 'L11' AND 'U3'. T. THE EC IS RESPONSIBLE FOR VERIFYING ALL PENDANT LENGTHS. FIELD VERIFY IF NECESSARY. U. WALL MOUNTED EXIT SIGNS ABOVE DOORS TO BE +0'-6" ABOVE FINISHED DOOR FRAME TO BOTTOM OF EXIT SIGN. WALL MOUNTED EXITS NOT LOCATED ABOVE DOOR TO BE MOUNTED AT 7'-6" AFF TO BOTTOM OF EXIT SIGN UNLESS NOTED OTHERWISE. V. TYPE 'X2' FIXTURES MOUNTED IN OPEN GARAGE TO BE HUNG ON RGID STEM WITH ALL-THREAD SO THAT THE TOP OF THE FIXTURE FALLS +0'-2" BELOW LOWEST STRUCTURAL MEMBER UNLESS NOTED OTHERWISE. W. P1, P1E, P2 AND P2E PENDANTS TO BE MOUNTED SO THAT THE BOTTOM OF THE FIXTURE IS FLUSH WITH THE BOTTOM OF THE STRUCTURAL BEAMS ON RIGID STEM UNLESS NOTED OTHERWISE. X. LIGHT FIXTURE TYPE 'U7' TO BE ON THE RESIDENCE UNIT'S RESPECTIVE LIGHTING CIRCUIT. SHOWN ON THIS PLAN FOR REFERENCE ONLY. 21071 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateTHE CONCOURSECarmel, IN 46032Carmel Review GRJK550 Monon BlvdNOT FOR CONSTRUCTIONEL103A 3RD FLOOR LIGHTING PLAN - AREA A 02/03/202302/03/2023 0 16'8'4' N1/8" = 1'-0" 3RD FLOOR LIGHTING PLAN - AREA A1 SHEET PLAN NOTES 1 LIGHTING FIXTURES IN THIS SPACE TO HAVE ON-BOARD OCCUPANCY SENSORS SET TO PROVIDE 100 PERCENT LIGHT OUTPUT IN OCCUPIED MODE AND 50 PERCENT LIGHT OUTPUT IN UNOCCUPIED MODE.