HomeMy WebLinkAboutEP101C - 1ST FLOOR POWER PLAN - AREA CJ J J GA GB GC GE GH GJGG 5 4 2 1 3 B.2 C.3 D D.5 E F H K LJ MD.2 4.6 D.7 GFG.9A 1.8 0.1 3.2 B.3 C.4 D.6 3.1 1.5 C.8 D.9 E.3 0.7A 0.7B GA.9 GI E.6 CUH-1 FCU-101 USB/USBC USB/USBC FCU-102 FCU-103 EF-2A EF-2B AUTO DOOR POWER AUTO DOOR POWER H1A- 65 H1A- 65 H1A- 65 H1A- 65 H1A- 65 H1A- 65 H1A- 65 H1A- 63 H1A- 63 H1A- 63 H1A- 63 H1A- 63 H1A- 63 H1A- 33 H1A- 35 H1A- 63 H1A- 59 H1A- 59 H1A- 59 H1A- 59 H1A- 59 EWH-1 HWRP-1 TMV-1 DWH-2 H1A- 41 H1A- 41 H1A- 23,25 H1A- 13,15 H1A- 49 H1A- 49 H1A- 68,70,72 H1A- 1 H1A- 48 H1A- 48 H1A- 48 H1A- 49 H1A- 14 +60" +60"H1A- 30H1A- 27 H1A- 10 H1A- 10 H1A- 10 H1A- 10 H1A- 10 H1A- 10 H1A- 31 H1A- 10 H1A- 4 H1A- 4 H1A- 4 H1A- 4H1A- 36H1A- 34H1A- 32 H1A- 11 H1A- 11 H1A- 62 H1A- 62 H1A- 62 H1A- 62 H1A- 62 H1A- 62 H1A- 62 H1A- 57 H1A- 57H1A- 57 H1A- 57 H1A- 57 H1A- 57 H1A- 2 H1A- 2 H1A- 2H1A- 26,28 EUH-4 C5- 31,33 EUH-4 H1A- 22,24 H1A- 67 H1A- 73,75,77 H1A- 20 H1A- 9 H1A- 9 H1A- 71 2 11 All work shown in this commecrial space is to be temporary to prevent fire system freezing tenant build out of this area not in scope of project unless noted explicitly. 3 3 3 3 3 4 H1A- 66 H1A- 66 H1A- 66 H1A- 66 H1A- 66 H1A- 66 H1A- 7 H1A- 7 H1A- 7 H1A- 7 H1A- 7 A. SEE SHEET E-000 FOR SYMBOLS AND ABBREVIATIONS. B. SEE SHEET E-502 FOR MECHANICAL EQUIPMENT POWER SCHEDULE. C. SEE SHEETS E-503 THROUGH E-505 FOR PANEL SCHEDULES. D. SEE SHEETS E-601 FOR ELECTRICAL DETAILS. E. WIRING SYSTEM SHALL BE CONDUIT AND CONDUCTOR UNLESS NOTED OTHERWISE. USE SOLID CONDUCTOR FOR SIZE #10 AWG AND SMALLER. USE STRANDED CONDUCTOR FOR LARGER SIZES. F. ALL COVER PLATES FOR ELECTRICAL DEVICES SHALL BE OF A COLOR TO MATCH THE AREA COLOR SCHEME AS DIRECTED BY THE INTERIOR DESIGNER. G. ALL WORK SHALL COMPLY WITH ALL NATIONAL, STATE AND LOCAL CODES AND ORDINANCES PERTAINING TO THE WORK IN THIS PROJECT. H. EXPOSED CONDUIT SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO BUILDING LINES. I. REFER TO ARCHITECTURAL DRAWINGS FOR DESIGNATION AND LISTING OF FIRE RATED ASSEMBLIES. COORDINATE ALL DESIGN EFFORTS WITH FIRE RESISTANCE OF MATERIALS AND CONSTRUCTION. J. ALL EXTERIOR EQUIPMENT AND DEVICES SHALL BE WEATHER PROOF AND RAIN TIGHT. K. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL INTERCONNECT WIRING FOR MECHANICAL AND PLUMBING EQUIPMENT FURNISHED BY OTHERS. GENERAL SHEET NOTES 21071 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateTHE CONCOURSECarmel, IN 46032Carmel Review GRJK550 Monon BlvdNOT FOR CONSTRUCTIONEP101C 1ST FLOOR POWER PLAN - AREA C 02/03/202302/03/2023 1/8" = 1'-0" 1ST FLOOR POWER PLAN - AREA C1 N 0 16'8'4' SHEET PLAN NOTES 1 PROVIDE USB/USBC RECEPTACLE AT ENDS OF ISLAND. MOUNT 12" FROM COUNTER TOP TO BOTTOM OF RECEPTACLE PLATE. 2 CONNECT UNDER COUNTER DISHWASHER VIA CHORD AND PLUG TO RECEPTACLE IN MILLWORK(PROVIDE GFI BREAKER AND PANEL). 3 EXTERIOR RECEPTS: SWITCHED CHRISTMAS LIGHT RECEPTACLES AT SOFFIT. PLACE SWTICH IN HALL NEXT TO JANITOR CLOSET.PROVIDE WEATHERPROOF WHILE IN USE COVER. 4 LIGHT SWITCH FOR EXTERIOR HOLIDAY RECEPTS.