HomeMy WebLinkAboutH-601 - HVAC DETAILSCONDENSING UNIT DISCONNECT MOUNTED DIRECTLY ON CONDENSING UNIT SHEET METAL COVER POWER WIRING AND REFRIGERANT LINES FROM BUILDING UP THROUGH ROOF IN CUSTOM SHEETMETAL DOG HOUSE THREADED PVC SUPPORT PIPE ON EACH CORNER ROOF MEMBRANE PIPE INSULATION BASE GALVANIZED CHANNEL SECURE PIPING TO SUPPORT WITH STRAP MOTOR DISCONNECT SWITCH BY UNIT MFGR. PIGTAIL CORD EXTERNAL ALUM. WIRE POST BY UNIT MFGR. REFER TO ARCHITECTURAL PLANS FOR ROOF CONSTRUCTION AUTO BACKDRAFT DAMPER SEE PLANS FOR DUCT SIZE ALUM. HOUSING FAN WHEEL BIRDSCREEN FLASH AND COUNTERFLAS H 16" HIGH PRE-FAB CURB PROVIDE HOLE THRU ROOF ROUTE WIRE OUTSIDE DAMPER, BY OTHERS ROOF CURB CAP WOOD NAILER PIPING PENETRATIONS THRU ROOF CURB TO BE SIGRIST EXIT SEAL OR EQUIVALENT. SECURE CURB DIRECTLY TO DECK FILL VOIDS AROUND PIPING W/ FIBERGLASS INSULATION FROM CLOSURE PLATE TO CURB CAP FIELD APPLIED CANT VERIFY ACTUAL ROOF CONSTRUCTION PROVIDE ROOF OPENING CLOSURE PLATE AND SECURE TO DECK ROOF CUTTING AND PATCHING BY M.C. REFRIGERANT PIPING TO ASSOCIATED FAN COIL UNIT INSULATED CURB CAP BY VENT MFGR. FASTENED TO NAILER WITH STAINLESS STEEL SCREWS REFRIGERANT PIPING TO BE ROUTED SUCH THAT PIPES ARE NOT TRAPPED. COUNTERFLASHING ROOF CURB TO BE PATE PC-2 W/ INSULATED CAP OR EQUIVALENT. SIZE ROOF CURB AS REQUIRED FOR REFRIGERANT PIPING AND ELEC. CONDUIT TO AND FROM MULTIPLE CONDENSING UNITS. JOINING AND ATTACHING FLEXIBLE DUCT SPECIFICATION: A. METALLIC FLEXIBLE DUCT SHALL BE ATTACHED USING A MINIMUM OF THREE #3 SHEET METAL SCREWS EQUALLY SPACED AROUND THE DUCTS CIRCUMFERENCE; DUCTS LARGER THAN 12"Ø SHALL HAVE A MINIMUM OF FIVE #8 SHEET METAL SCREWS. SCREWS SHALL BE LOCATED AT LEAST 1/2" FROM THE DUCT END. B. NON-METALLIC FLEXIBLE DUCT SHALL BE SECURED TO THE SLEEVE OR COLLAR USING A DRAW BAND. IF THE DUCT COLLAR EXCEEDS 12"Ø, THE DRAW BAND MUST BE POSITIONED BEHIND A BEAD ON THE METAL COLLAR. C. INSULATION AND VAPOR BARRIERS PRESENT ON FACTORY-FABRICATED DUCTS SHALL BE FITTED OVER THE CORE CONNECTION AND SHALL BE SUPPLEMENTALLY SECURED WITH A DRAW BAND. D. FLEXIBLE DUCT SEALING SHALL BE A CLASS "B" SEAL FOR LOW PRESSURE SUPPLY. RECTANGULA R SUPPLY DUCT SPIN-IN FITTING W/VOLUME DAMPER FLEX DUCT-MAXIMUM 6'-0" LENGTH AND NO MORE THAN ONE (1) 90° BEND. SQUARE TO ROUND FITTING CEILING SUPPLY DIFFUSER 90° METAL ELBOW TYPICAL AT ALL DIFFUSER CONNECTIONS FLOOR TO FLOOR STRUCTURE OR BULKHEADALL CONCEALED 4" DRYER DUCT SHALL BE NON- CORRUGATED SMOOTH METAL WITHOUT SCREWS. EXTERIOR WALL CAP WITHOUT SCREEN.TRANSFER GRILLES ON EACH SIDE, CENTERED ABOVE DOOR. SIZE DICTATED BY ENLARGED PLANS. DRYER BOX IN SIDE WALL MOUNTED AT HEIGHT DETAILED IN ENLARGED PLANS. WALL -SEE ARCHITECTURAL PLANS EXHAUST DUCT - MOUNT TO DRYER WALL VENT ACCORDING TO MANUFACTURERS RECOMMENDATIONS DRYER WALL VENT -MODEL #DWV4. COLOR TO BE SELECTED BY ARCHITECT DAMPER WITH MAGNETS FINISHED INTERIOR MIN. 32" SQUARE DOOR MIN. 30" WATER HEATER PAN WATER HEATER MECHANICAL EQUIPMENT PLENUM CLEARANCE RACK REFRIGERANT LINE SETS ON SIDE WALL OF MECH ROOM RETURN GRILLE, SEE PLANS CONDENSATE DRAIN; ROUTE TO FLOOR DRAIN PROVIDED MAIN SHUT-OFF SUBMETER WATER HEATER WATER HEATER PAN SLEEVE FLEX CONN. DUCTFIRE DAMPER W/ACCESS PANEL FAN COIL WATER HEATER HW CW VALVE SIDE VIEW TOP VIEW NOTE: TYPICAL CONDITION SHOWN, REFER TO MECHANICAL AND PLUMBING FLOOR PLANS FOR ADDITIONAL REQUIREMENTS. CEILING RADIATION DAMPER PLENUM BOX OR ELBOW, R/D=1.5 MIN. 20"REFER TO PLANS16" MINNOM. 45"12"MIN.NOM.36"FIRE PARTITION BY CONTRACTOR; WITH FOAM SEAL.4"NOTES: 1. ROUTE CONDENSATE PIPING (SIZE PER MANUFACTURER) TO FLOOR DRAIN. 2. REFER TO REFRIGERANT PIPING DETAIL ON MECHANICAL DETAIL SHEET FOR ASSOCIATED REQUIREMENTS. 3. REFER TO STRUTURAL UNIT PLAN DRAWINGS FOR ACTUAL CONDITION AT EACH CLOSET. HARD DUCT MAIN ALWAYS ROUTES PARALLEL TO JOINTS. 4. COORDINATE HARD DUCT ELEVATION AT JOIST SPACE WITH FIRE AND PLUMBING PIPING PRIOR TO INSTALLATION. 5. FIRESTOP ALL PENETRATIONS AT CEILING, FLOOR AND THROUGH FCU SUPPORT. 21071 Project: Developer: Sheet Number: Engineer: By: Sheet Title: CDG Number: Last Revision Date: Set Issue Date Drawn By Checked By Sheet Issue DateTHE CONCOURSECarmel, IN 46032Carmel Review JBAJAddressNOT FOR CONSTRUCTIONH-601 HVAC DETAILS 02/03/202302/03/2023 NOT TO SCALE Condensing Unit Detail2 NOT TO SCALE Pipe Roof Support Detail3 NOT TO SCALE Typical Exhaust Fan (Flat) Detail5 NOT TO SCALE Typical Rooftop Piping Installation Detail4 NOT TO SCALE Typical Supply Diffuser Installation Detail6 NOT TO SCALE Typical Dryer Vent Connection Detail7 NOT TO SCALE Exhaust Vent Cap Detail8 NOT TO SCALE Wall-Mounted FCU Above Water Heater Detail1