HomeMy WebLinkAboutP-601 - PLUMBING DETAILS40" MIN.36" MIN.
DOOR MIN. 30"
WATER HEATER PAN
WATER HEATER
FAN COIL UNIT
PLENUM
CLEARANCE
RACK REFRIGERANT
LINE SETS ON SIDE
WALL OF MECH ROOM
RETURN GRILLE,
SEE PLANS
CONDENSATE DRAIN;
ROUTE TO HUB DRAIN
MAIN SHUT-OFF
WATER HEATER PAN
SLEEVE
FLEX
CONN.
DUCTFIRE DAMPER
W/ACCESS PANEL
FAN
COIL
UNIT
WATER HEATER
DWH-1
HW CW VALVE (TYP.)
SIDE VIEW
TOP VIEW
NOTE: TYPICAL CONDITION SHOWN, REFER TO HVAC AND
PLUMBING FLOOR PLANS FOR ADDITIONAL REQUIREMENTS.
CEILING
RADIATION
DAMPER
PLENUM BOX OR
ELBOW, R/D=1.5
MIN. 20"9'-0" REFER TO PLANSSEE HVACPLANSSEE HVAC PLANS12"MIN.NOM.36"FIRE PARTITION BY
CONTRACTOR;
WITH FOAM SEAL.4"NOTES:
1. ROUTE CONDENSATE PIPING (SIZE PER
MANUFACTURER) TO HUB DRAIN.
2. REFER TO REFRIGERANT PIPING DETAIL
ON HVAC DETAIL SHEET FOR
ASSOCIATED REQUIREMENTS.
3. REFER TO STRUCTURAL UNIT PLAN
DRAWINGS FOR ACTUAL CONDITION AT
EACH CLOSET. HARD DUCT MAIN ALWAYS
ROUTES PARALLEL TO JOINTS.
4. COORDINATE HARD DUCT ELEVATION AT
JOIST SPACE WITH FIRE AND PLUMBING
PIPING PRIOR TO INSTALLATION.
5. FIRESTOP ALL PENETRATIONS AT
CEILING, FLOOR AND THROUGH FCU
SUPPORT.
NOM. 30"
T&P VALVE, ROUTE
DRAIN LINE TO HUB
DRAIN
4" HUB DRAIN
2" WASTE
TRAP SHALL NOT BE INSTALLED
BELOW FLOOR BUT SHALL
BE ROUGHED IN NOT LESS
THAN 6" AND NOT MORE
THAN 18" ABOVE FLOOR
NO STANDPIPE RECEPTOR SHALL
EXTEND MORE THAN 30" NOR
LESS THEN 18" ABOVE ITS TRAP
1 1/2" VENT
1/2"CW
1/2"HW
SHUTOFF VALVE WITH THREADED
HOSE CONNECTION
2" WASTE
P-TRAP WITH UNION
CONNECTIONS
FLOOR LINE
CLOTHES WASHER RECESSED
WALL BOX WITH FACE PLATE;
EQUAL TO GUY GRAY SERIES
RECESSED WALL BOXES
SINK
SHUT-OFF VALVE
REDUCER
GARBAGE
DISPOSAL
5/8" DRAIN
HOSE
1 1/2" VENT
2" SAN
DISHWASHER
1/2" HW
CW SUPPLY
HW SUPPLY
CODE APPROVED
AIR ADMITTANCE
VALVE (AAV)
COUNTERTOP
INSTALL AS HIGH AS
POSSIBLE UNDER
THE COUNTERTOP
4" MIN.
SLOPE
RISER PIPE SAME
AS SEWER
18"x18"x8" THICK
CONCRETE PAD
ROUND FLANGED HOUSING
W/ HEAVY DUTY CAST IRON
COVER LIKE J.R. SMITH 4251
CLEANOUT PLUGFINISH GRADE
2-WAY FITTING
SYSTEM RISER
CAST IRON FLANGE
AND SPIGOT PIECE
CAST IRON BELL
AND SPIGOT PIPE
THRUST BLOCKING
RODS
FIRE SERVICE
MAIN
RESTRAINT
BUILDING SLAB
SLOPE
RISER PIPE SAME AS SEWER
FINISH FLOOR
CLEANOUT BOX WITH RECESSED
SOLID COVER
BRONZE PLUG
MAXIMUM MOUNTINGHEIGHT OF 5'-0"ABOVE FLOORBFP-1
BFP-2
METER
REDUCED PRESSURE ZONE
TYPE BACKFLOW PREVENTER
4"CW TO
BUILDING
SERVICE
PROVIDE REMOTE WATER
METER READ OUTS, SEE
FLOOR PLANS FOR LOCATION
NEEDLE VALVE
PRESSURE GAUGE
FINISHED FLOOR
SEE SPECIFICATIONS FOR PIPE
SUPPORT REQUIREMENTS
TYPICAL DRAIN FUNNEL WITH AIR
GAP, TERMINATE DRAIN LINE OVER
NEAREST FLOOR DRAIN
4"CW INCOMING SERVICE
FLOOR SLEEVE
COUPLING ADAPTOR (TYP)
GATE VALVE (TYP)
1. ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH UTILITY COMPANY'S
REQUIREMENTS. WATER METER FURNISHED BY LOCAL UTILITY, CONTRACTOR INSTALLED.
NOTE:
4"CW 4"CWSTRAINER (TYP)
THREADED
CLEANOUT PLUG
TEST TEE ACCESS COVER AND FRAME
FINISHED WALL SURFACE
PIPE
DOUBLE SUPPORT NUT
LOCKING NUT
HANGER ROD HANGER ROD
LOCKING NUT
SUPPORT NUTCLEVIS HANGER
14 GAUGE ZINC COATED
SHEET STEEL SADDLE
AT LEAST 12" LONG
PIPE
INSULATION
INSULATION
PREFORMED PIPE SUPPORT INSERT,
SAME THICKNESS AS INSULATION
MANUFACTURED FOR THIS PURPOSE
AT REFRIGERATORS = 12" AFF.
AT ICE MACHINES = 12" AFF.
AT COUNTERS = 1" ABOVE COUNTER BACK SPLASH,
FOR COFFEE MAKER SUPPLY
VARIESREFRIGERATOR ICE MAKER
RECESSED WALL BOX WITH
FACE PLATE; EQUAL TO OATEY
SERIES RECESSED WALL BOXES
ANGLE STOP VALVE WITH
THREADED CONNECTION
FOR ICE MAKER TUBING
1/2"CW
FLOOR LINE
3/4"HW
3/4"CW
BALL VALVE
CHECK VALVE
THERMAL EXPANSION
TANK ET-1
SUPPORT FROM
STRUCTURE
VACUUM RELIEF
VALVE
ASME APPROVED TEMP. &
PRESSURE RELIEF VALVE.
TERMINATE RELIEF DRAIN LINE OVER
MOP BASIN WITH MINIMUM 4" AIR GAP
PAN ASSEMBLY DRAIN,
TERMINATE OVER MOP BASIN
WITH MINIMUM 4" AIR GAP
ELECTRIC
WATER
HEATER
DWH-3
TANK
DRAIN
SUPPORT PLATFORM ASSEMBLY
WITH DRAIN PAN AND SUPPORT
BRACKETS. EQUAL TO HOLDRITE
#30-SWHP-WM. INSTALL PER
MANUFACTURER'S REQUIREMENTS
ALL-THREAD
SUPPORT
RODS
UNION
(TYPICAL)
THERMOMETER
CW
HW
INSULATION
BLOCKING
UNI-STRUT TRAPEZE SUPPORT
STRUT PIPE CLAMP
PIPE INSULATION MATERIAL
(REFER TO SPECIFICATIONS)
SYSTEM PIPE (REFER TO
DRAWINGS FOR TYPE OF
SYSTEM AND PIPE SIZE)
FLEXIBLE
ELASTOMER
MATERIALTHREADED
STEEL HANGER
ROD
STEEL ROD
COUPLING
TRIM ALL THREAD
ROD BELOW
TRAPEZE SUPPORT
TO NO MORE THAN
1/2"48" A.F.F. IN MECH CLOSETSRECESSED WALL VALVE BOX WITH
FACE PLATE; EQUAL TO ACUDOR
ARVB RECESSED WALL VALVE BOXES
SHUT-OFF
VALVE
FLOOR LINE
CW, SEE ENLARGED
FLOOR PLANS
CW, SEE ENLARGED
FLOOR PLANS
12"PENETRATION BOOT & FLASHING TO
MEMBRANE ROOFING BY ROOFING
CONTRACTOR
PROVIDE STAINLESS STEEL
CLAMPING BAND
SURE SEAL WATER CUT-OFF MASTIC
ROOF DECK -SEE ARCHITECTURAL
DRAWINGS FOR CONSTRUCTION
OPENING IN DECK BY PLUMBING
CONTRACTOR
SEE DRAWINGS FOR SIZE
INCREASER AS REQUIRED
PIPE SIZE PER DRAWINGS
CARRIER PIPE
WATER STOP AND
ANCHOR COLLAR
WALL
WALL SLEEVE
MECHANICAL INTERLOCKING
RUBBER LINKS TYPE WALL
PENETRATION SEAL
CONTROL PANEL
AND VFD'S
HYDROPNEUMATIC TANK
TYPICAL
PUMP TYPICAL FLEXIBLE
CONNECTOR
FLOOR
CONCRETE HOUSEKEEPING PAD
NORMALLY CLOSED FULL
LINE SIZE BY-PASS
PRESSURE REGULATING
VALVE AND CHECK VALVE
TYPICAL SHUT OFF VALVE
TYPICAL CHECK VALVE
CW TO
BUILDING
SERVICE
CW FROM BFP'S, AND
WATER METERS
NOTE: REFER TO SCHEDULE AND SPECIFICATIONS FOR ACTUAL QUANTITY OF PUMPS.
CW
HW (120°F)
HWR (120°F)
THERMOMETER
HW (140°F)
DOMESTIC WATER HEATER
(DWH)
HW (140°F)
THERMOSTATIC MIXING
VALVE (TMV)
FLOOR
FLOOR
DRAINCONCRETE PAD
TANK DRAIN
CW
ASME APPROVED TEMP. &
PRESSURE RELIEF VALVE,
TERMINATE RELIEF DRAIN
LINE OVER FLOOR DRAIN
THERMAL
EXPANSION TANK
BALANCING VALVE
3/4"CW
ANTI-SIPHON SPILL RESISTANT
VACUUM BREAKER BACKFLOW PREVENTER
EQUAL TO WATTS LF008PCQT
3/4" IPS PIPING
SANITIZING VALVE
(BY OTHERS)
FLUSHING SPRAY
HEAD (BY OTHERS)
TRASH CHUTE
SHUT-OFF VALVE
SIPHON TUBE
(BY OTHERS)
ONE GALLON SANITIZING
BOTTLE AND LOCATION
(BY OTHERS)
STRAINER
21071
Project:
Developer:
Sheet Number:
Engineer:
By:
Sheet Title:
CDG Number:
Last Revision Date:
Set Issue Date
Drawn By Checked By
Sheet Issue DateTHE CONCOURSECarmel, IN 46032Carmel Review
GRJK550 Monon BlvdNOT FOR CONSTRUCTIONP-601
PLUMBING DETAILS
02/03/2302/03/23
NOT TO SCALE
APT. WATER HEATER & FAN COIL UNIT DETAILA
NOT TO SCALE
CLOTHES WASHER BOX PIPING DETAILB
NOT TO SCALE
DISHWASHER/DISPOSAL DETAILC
NOT TO SCALE
EXTERIOR CLEANOUT DETAILD
NOT TO SCALE
FIRE SERVICE CONNECTIONE
NOT TO SCALE
INTERIOR CLEANOUT DETAILF
NOT TO SCALE
MULTIPLE WATER METER PIPING DETAILG
NOT TO SCALE
NO HUB CLEANOUT W/ ACCESS DOOR DETAILH
NOT TO SCALE
PIPE HANGER DETAILI
NOT TO SCALE
RECESSED WATER VALVE BOXJ
NOT TO SCALE
SUSPENDED WATER HEATER PIPING DETAILK
NOT TO SCALE
TRAPEZE DETAILL
NOT TO SCALE
UNIT RECESSED WALL VALVE BOX DETAILM
NOT TO SCALE
VENT THRU ROOF DETAILN
NOT TO SCALE
WALL/FLOOR SLEEVE DETAILO
NOT TO SCALE
WATER BOOSTER PUMP PIPING DETAILP
NOT TO SCALE
WATER HEATER PIPING DETAILQ
NOT TO SCALE
TRASH CHUTE SANITIZER DETAILR