HomeMy WebLinkAbout06070183 Site Plan
.--
'1
Schneider
Tho _ Corporation
BOOlotllA....,.
1llIlorIo rorl _
h..H.iI'lpI'lI, ID.d1au. 48218-1037
817-828-71110
817-828-72110 rAI
IDgInaerin(
SIlm1IJl&
LoIllIIcal"'-
GJS.Ull
GooIo&1
Note:
This drawing Is based on construction plans or record drawIngs,
and is not based upon a field survey. The Schneider Corporation
does not worront the accuracy or sufficiency of this information.
Contractors should verify existing conditions prior to any
construction. MY discrepancy found on this drawing should
be reported to The Schneider Corporation immediately, foiling
to do so results In the contractors assumption of all liability.
This Plot Pion Prepored For: Arbor Homes
Lot # 23 ,contoining 14,419 S.F.:l:, in
The Troils ot Hoyden Run Sec. 1
INSTR. # 200500069468
Cloy Twp, Homilton County
Sec 20, T29N, R3E
3132 FRAMINGHAM LANE
Westfield, IN 46074
Prepored Dote: 07/26/06: By: KA,G.
Community Restrlctlon~
Side Yard -3" min.
Rear Yard := 20'
Aggregate - 6' (B.H.)
(50'R/W)
Arbor Homes
finished Floor Elevation Infonmation
Pod Grode = 921.4 per plan
Pod Grode + to' = Garage FIT (922.4)
Garage FIT + 0.5' = Residential FIT (922.9)
Residential FIT - 10.0' = Basement FIT (912.9)
Note : The garage finished floor elevation
Is 1.7' above the curb at the drive, per
plan.
GROUND COVER CALCULA nONS:
Drive = 1,291 Sf:!:
Public Walk =4S5 Sf:!:
Privale Walk =194 Sf:!:
Seeding = 6,039Sf:!: .
Sod = 4707 Sf:!: ,
even wlill the rear of house.
Nate:
The contractor Is 10 malnloln 0
minimum d~lonce of ten fset (10')
betwson the eanltry ..wer and woter
line 101,,01&
NOlE:
SUMP PUMP(S) TO BE PLAC!D
BY BUILDER AS NEEDED.
Nole:
The basemenl elevalion, depleted hereon, has
been detenmined and based upon the pod
grades and/or conlours laken from the
construction plans for this subdivision. Unless
staled, no Information aboul fluctuallng water
lables, soli conditions, or soli types has been
provided or slaled on soid plans. II Is
recommended that the basemenl flnlshed floor
elevallons be alleasl Iwo feel (2') above the
nonmal pool e1evallon of any adjoining bo4i"~
of woler, unless 0 sludy of facts reveal...._
otherwise. If during the excavation proceSs'rony
ground water Is witnessed, The Schneider
Corporation should be notified immediately. The
basemen I e1evallon should be raised two feel
(2') above the ground w~ I
construction tcenlq eSshould be Inco ora
to allevlole future roblem&
-rff/- MHI811
/ , TCa92o.55
PER RECORO
DRAYllNG
,\\\\\\\\\IIIIII/jll/H/iii;
#~t. L /' ~/%
~.~ fJJ ~
~~..............)fc0~~
~~~...tG\S TF:Iti........A~
g~""<t- No. ().....;c~
, ( S0303 ) I
% ..... STATE OF ..... ~
~ <~.....I"'O'A~""""~~
~ -Y #; ................i:" '\:l ~
~/,I/, SUR~\.,,#
1Jllf""I/IIIII\\\I\\\\\\~
~l'f11
Plot Pion Legend
[jjQ[[J Proposed Grad..
000.0 Existing Grodes
-000.0- Conlour Grode
* Approx. Lateral location
- . - Sanitary Sewer Unes
-IT- Storm Sewer Unes
- IJ - Water Service Unes
- - - - - - - Sub-Surface Drain Unas
. Manhole (Scnltory or Storm)
. Beehive Inlet (Storm)
IlII Curb Inlet (Storm)
D End-S8i:t1on'(St6rin)
... r.e Hydrant
- " " " - " " " - Flow Una of swole
Note: Sanitary Sewer
Top of Casling Infonmallon
Upstream Manhole, TC= 920.55
Downstream Monhole, TC=921.45
per record drawing.
LOT # 23
VB # 06.0058741
OetaR of t)!llcal Storm
Water flow pattern for
Indl>iduollots.
I I
:G:
I I
~
~
=[i::3o
~
Assumed North
Scale: I' = 30'
Note: Builder to ensure
positive drainoge Qway
from structure{s).
94.00'
on
on
a;
...
...
...
30' L.M.A.E.&R.D.E.
61.0' 60.0' _
- 1920.41- - - - - - 1920.4 I--
I
I
I
I
I
I
I
I
I
I
I
I
"8 17.110 "8 Ol:CK
r...: r...:
SOl)
29.110
SUMP
PUMP
~
-l>o
9
(J1
N_
~
-..J
?'i:l
VJ;li
"'-
MA mRHORN B
FRII&llSY
RESIDENCE
BASEMENT
CONC
ORIVE
6.0'
5.1
\ VAR. D.U.&S.S.E.
:>
THREE CAR
>- GARAGE
~
V R. B.L.::: 22. .
.
g;
~~
:.:.
ROll CURB
FF
~
d
N
'"
ElEV-920.7
PER PlAN
~.
:i
b
.,.. .1 <;A,rRt
~ .'
TYPICAL SWALE SECTlON
RE\lSlON "
RE\lSED GARAGE PER FAX
07/27/06 - KAG
Note:
Per Carm~ zoning ordinance 26.1.1 : The resldenllal
district limite height to twenty-flve fset (25'), however
o dw~lIng may be Increased In height to thlrly-flve
fset (35') pro>ided the side and rear yards are Increased
on oddltlonol one foot (1') for each one foot (1') the
struclure exceeds the f..t Iwenty-flve fsel (25') In
helghl
ThIIctvmg II not htned to be I'eprIIIlllltad 011 G retn:lcem<<It tX
orlglI<llbclxldcry_.routG_rr.!lnol"lDcatlo1R'9"l-
Rood Hazard Stotement The _racy of any flood hazard data shown on this reparlls sub)ocl to map
ae uncerlalnlY.CSld.to CSly other uncertal11y I1locol1on or ~e"'~on on the referenced flood Insurance
rate map. All of the w1thl1 described land DOES NOT UE within that epeclol flood hazard zone A as said
land plots by oede an flood l1euronce role mop , lB057C0205f for City of Carm~, Indlano (maps dated
FebNcry 19, 2D03~