Loading...
HomeMy WebLinkAbout06070191 Site Plan ~' ~:1 !he IlcImoIder CorporatioD . ;;:~=-_'-103? ,/ 317-828-'1100 Schleider 817-828-7200 FAI ~ Sune7iDI LaDdIoape - GJS.Ull lleoIoo Plot Plan Leqend !JiliQ]J Proposed Grades 000.0 E,lstlng Grades __ 000.0-- Contour Grade * Appro,. Lateral Location _ . - Sanitary Sewer Lines _ If- Storm Sewer Lines _ '.J - Water Service Unes _ _ _ - - - - Sub-Surface Drain Unes . ~anhale (Sanitary ar Storm) . Beehive Inlet (Storm) 11III Curb Inlet (Storm) D End Section (Storm) .... Fire Hl"rant _"" 0 _ ",," - Flow Line of swale This Plot Plan Prepared For: snver Thome Homes Lot # 45, containing 23,553 5.F.t, in Aberdeen Bend Subdl~slan Instrument # 200500066134 P.C. # 3, Slide # 739 HA~IL TON COUNTY, QA Y TO\\tjSHIP 12819 PETRONIA COURT (50' RjW) Carm~, IN 46032 Prepared Dote: 07/07/06 By. KAG . Community Restrictions: Side Yard = N/A Rear Yard = 25' Aggregate = 30' Zoning = Sl SlIverthome Homes. LLC. Finished Floor Elevation Information Pod Grade = 913.0 per plan Pod Grade + 1.0' = Garage FIT (914.0) Garage FIT + 0.5' = Residential FIT (914.5) Residential FIT - 10.0' = Basement FIT (904.5) Note : The garage finished floor ~evation Is 2.0' above the curb at the drive, per plan. Ground Caver Calculations: Drive = 1.253 SFt Public Walk = 521 SFt Private Walk = 202 SF t Seed = 13.271 SFt Sod = 6,392 SFt.!rom rear of home. / ABB109 TC=913.00 PER PLAN Note: Sanitary Sewer Top of Costing Information Upstream ~anhale, TC= 912.90 Downstream ~anhole, TC=913.00 per plan. ABB110 TC=912.90 PER PLAN ~\\\\\\\\\\I\1IIl/IJI/I/II!. >$>\\\~ C. L ,,~~@ ~ ,~ tiP ~ ff.~" ""''''''"....:1' ~J~ ~ ~~ ..tG\s TF:~i-" ....A~ ~ ~ lq. No 6.....;0~ I ( 50303 ) 1 ~ \ i g ~ ". STATE OF... ~ :a. /.... .... if? ~'C A '..(.vOIA"""':'" ~~ ~ "'4'/) """""""'(,"\" # ~/!. SUR't ,,~.# WIII/lf/IJIII\I\\\\\\\\\\~ -0-:-lFf This <<owing Is not Intended to be represented os a retracement or original boundary BUM)'. Q fClllte lll.IfW)'. or 0 Swwp LocGtlon Report. flOOD HAZARD STATEMENT The accuracy of any flood hazard data shown 00 this plot plan is subject to mop scale uncertainty and to any other uncertainty In location or elevation on the referenced flood insurance rate map. ALL of the within described land DOES NOT UE within that special flood hazard zone A as sold land plats by scale on community-panel # 180080 0205F of the flood Insurance rate mope for Fishers. IN (maps doted Feb. 19. 2003). ."- , , '-" Note: This drawing is based on construction plans or record drawings, and is not based upon 0 fi~d survey. The Schneider Corporation does nat warront the accuracy or sufficiency of this information. Cantracto", should verify existing conditions prior to any construction. Any discrepancy found an this drawing should be reported to The Schneider Corporation Immediately; foiling to do so results in the contractors assumption of 011 liability. LOT# 45 VB06.0057544 Oetai of t:,pical Ground Water flow pattern for individual iota ~ ~ =~= ~ Assumed North Scale: 1. = 40' ~ . M--, -~- ' - - -- Note: Builder to ensure positive drainage away from structure(s), NOTE: IN THE RESIDENTIAL OISTRIClS UNITING H~GHT TO TWENTY-AYE (25) FEET. A OWEWNG ~AY BE INCREASED IN H~GHT TO THIRTY-AYE (35) FEET PRO'llOEO THE SIDE AND REAR YAROS ARE INalEASED AN ADDITIONAL FOOT FOR EACH FOOT SUCH STRUCTURE EXCEEDS TWENTY-AYE (25) FEET IN H~GHl PER CARNEL ZONING ORDINANCE 26,1.1. ~ TYPICAL SWAl}; SECTION / 210.25 ~ :;! " =l l<l ,20.1 x~ ~ 8 is 125.1' 262.34 NOTE: SU~P PU~P(S) TO BE PLACED BY BUILDER AS NEED EO, NOTE: THE BASE~ENT ElEVAllON DEPICTED HEREON HAS BEEN DmRMINEO AND BASED UPON THE PAD GRADES AND OR CONTOURS TAKEN FROM THE CONSlRUCllON PLANS FOR THE SUBDIVISION. UNLESS STAlED. NO INFORMAllON ABOUT F1.UClUATING WATER TABLES. SOIL CONDITIONS OR SOIL TYPES WITHIN THE aUiLO:NG AREA HAS 8EEN PROVIDED OR STAl'EO ON SAID PLANS. IT IS RECOMMENDED THAT BASEMENT ANISHED F1.00R ELEVATIONS BE AT LEAST (2) FEET ABOVE THE NORMAL POOL ELEVATION OF ANY AQJOfNING BODIES OF WATER UNLESS A SnJDY OF FACTS REVEALS QTHERWlSE.1F DURING THE EXCAVA'TlON PROCESS, ANY GROUNDWA'TER IS WITNESSED, 'THE SCHNEIDER CORP. SHOULD BE NOllAED lMI.4E01ATELY. ll-lE BASEMENT ELEVATION SHOULD BE RAISED (2) FEET ABOVE THE CROUNOWA TER LEVEL AND ADDITlONAL CONSTRUCTION lECHNIQUES SHOULD BE INCORPORATED TO ALLEVlA lE FUlURE PROBLEMS. Note: The contractor Is to maIntain a minimum dIstance of ten feet (10') between the sanitary sewer and water line laterals. PLEASE NOTE THAT THE STRAIGHT UNE SLOPE Of THE ORIYEWA Y FRON THE GARAGE FINISHED FLOOR ELEVATION TO THE TOP Of THE CURB AT THE CENTER Of THE DRIYEWA Y EXCEEDS 5% AS PROPOSED, THIS SLOPE IS BASED ON THE REOUIRED ~INI~U~ GARAGE FINISHED FLOOR ELEVA]QN AND THE EXISTING TOP OF CURB ELEVATION.