Loading...
HomeMy WebLinkAboutP601 - Plumbing Schedules & DetailsPlumbing Fixture Schedule Mark No. Description HW CW W V Pipe Connections (in)Model Numbers Acceptable Manufacturers WATER CLOSET - WC-1 - 1 3 2 WATER CLOSET - WC-1A - 1 3 2 URINAL - UR-1A - 3 4 2 11 2 LAVATORY - L-2A 1 2 1 2 11 2 11 4 SINK - SK-1A 1 2 1 2 11 2 11 2 MOP SINK - Floor mounted, 24" X 24", cast polymer. Provide hose with hanger, mop hook, p-trap, ss strainer, ss wall guards. Service faucet with vacuum breaker. Seal at wall. MS-1 3 4 3 4 3 2 FIAT, SWAN, MUSTEE, STERN WILLIAMS CHICAGO, T&S, ZURN FLORESTONE #MSR-2424 SPEAKMAN #SC-5814 FLORESTONE #MR-370, MR-372, MR-373 FIAT, SWAN, MUSTEE, STERN WILLIAMS FLORESTONE #MR-375, MR-377 FIAT, SWAN, MUSTEE, STERN WILLIAMS SHOWER - SH-1 1 2 1 2 3 2 TRANSFER SHOWER - SH-1A 1 2 1 2 3 2 BOTTLE FILLER - Filtered water dispenser, sensor operated. Provide p-trap, supplies and stops. Mount per ADA requirements at +341 2" A.F.F. to shelf. BF-1A - 1 2 11 2 11 4 ELKAY #ER101YREMOTE CHILLER - Electric, refrigerated, 10 GPH. Provide drain RC-1 -1 2 WATER HEATER - Gas, high efficiency, 100 gal storage tank, 188 GPH recovery @ 90°F rise, 150,000 BTU. Provide ventless gas pressure regulator, suitable for site gas pressure, set to mfgr's recommendations. Thermal expansion tank. Set outlet temperature to 140°F. Condensate neutralization kit. WH-1 3 4 3 4 (2) 3- A.O. SMITH, BOCK, LOCHINVAR, RHEEM, STATEBRADFORD WHITE #EF-60T-150E-3N AMTROL #ST-12 A.O. SMITH, TACO A.O. SMITH, BOCK, LOCHINVAR, RHEEM, STATEBRADFORD WHITE #A2123601 3 4 3 4 MV-1 MIXING VALVE - ASSE 1017. Thermostatically controlled, temperature and pressure compensated. Provide with unions, check stops, shut off valve & thermometer. Set outlet temperature to 110°F. - - BRADLEY, LEONARD, SYMMONS LAWLER #84008-61-25 GRUNDFOS #UP 15-18 B5 & #599388RECIRCULATING PUMP - 1 GPM @ 10' of head. 24 hr programmable time clock.RP-1 LINE SIZE LINE SIZE - -BELL & GOSSETT, TACO FLOOR DRAIN - Cast iron body, nickel bronze round flat strainer. Deep seal p-trap with trap seal.FD-1 - --2 ZURN #ZN415-BZ1 J.R. SMITH, JOSAM, MIFAB, SIOUX CHIEF, WATTS SURE SEAL #SS2009V J.R. SMITH, ZURN FD-1 - --4FLOOR DRAIN - Cast iron body, nickel bronze round flat strainer, 4"Ø funnel. Deep seal p-trap with trap seal.SURE SEAL #SS4009V J.R. SMITH, ZURN ZURN #ZN415-BZ1-4 J.R. SMITH, JOSAM, MIFAB, SIOUX CHIEF, WATTS ROOF DRAINS - Packaged roof drain system with roof and overflow drains. Cast iron bodies, aluminum domes, gravel stops. Verify roof type. RD-1 - - LINE SIZE -JOSAM, J.R. SMITH, MIFAB, WATTSZURN #ZA164 CO-1 FLOOR CLEAN OUT - Cast iron body, round scoriated nickel bronze top, bronze plug. ZURN #ZN1400-BZ1-BP - - - J.R. SMITH, JOSAM, MIFAB, WATTS4 EXTERIOR CLEAN OUT - (Paved areas) Cast iron body, heavy duty round scoriated nickel bronze cover, bronze plug. (Unpaved areas) Cast iron body, bronze plug. CO-2 ZURN #ZN1400-HD-BP- --JOSAM, J.R. SMITH, MIFAB, WATTS JOSAM, J.R. SMITH, MIFAB, WATTS4 ZURN #Z-1440-BP (UNPAVED AREAS) WILKINS #375XLREDUCED PRESSURE ZONE BACKFLOW PREVENTER - Make and model as approved by the Ind. Dept. of Health.RPZ-1 1- - -CONBRACO, FEBCO, WATTS WOODFORD #67 FREEZE PROOF HOSE BIB - Wall mounted, cast bronze valve, chrome plated face plate, automatic draining, stainless steel stem, integral backflow protection. FPHB - 3 4 - - ELKAY #LBWDC00 BOTTLE FILLER - Filtered water dispenser, sensor operated. Provide p-trap, supplies and stops. Mount per ADA requirements at +341 2" A.F.F. to shelf. BF-1 - HALSEY TAYLOR, HAWS, OASIS1 2 11 2 11 4 ELKAY #LBWDC00 HALSEY TAYLOR, HAWS, OASIS HALSEY TAYLOR, HAWS, OASIS3 4 ELKAY #ER51YREMOTE CHILLER - Electric, refrigerated, 5 GPH. Provide drain RC-2 -1 2 HALSEY TAYLOR, HAWS, OASIS 3 4 GUY GRAY #T200 WB-1 WASHER UTILITY BOX - 2"Ø Standpipe MUST tie into 3"Ø horizontal drain pipe. Provide with LT-1. 3 4 3 4 2 11 2 OATEY, WATER-TITE LT-1 LINT TRAP - Cast aluminum, bottom access, gasketed cover, removable filter screens, bronze frame.-2 STREIM #SIDEKICK- - SIOUX CHIEF #696-3 & 696-LCDRAIN BOX - White, ABS box with trim panel. Louvered cover plate.DB-1 2 - -11 4 Overflow drain w/strainer Pipe hanger 4" min. NOTES: 1. Roof and overflow drain to be of identical size as noted on drawings. 2. Roof drain and leader sizing to be in accordance with Ind. Plumbing code. 3. Insulate Piping and Sump. Clean-out plug Deck clamp Sump Slope in direction of flow 12" min./24" max. Roof drain w/strainer NOTE: Details shown here are typical only and may not be complete. Contractor shall provide all material and labor necessary for the configuration, piping and accessories required to operate this system in the manner intended with complete safety. Gas cock Dirt leg To floor drain Water heater 3"Ø flue Min. 3 4"G ASME T&P relief valve (typ) Dielectric union (typ) 3"Ø intake Thermometer Recirculating pump (RP-1) Check valve (typ) 31 2" Conc. pad Mixing valve (MV-1) locate below water line Floor Tank drain Thermometer (typ) Thermal exp. absorber. Support as necessary. Ball valve (typ) Strainer 1 2"HWR 1"CW 1"HW N.C. N.C. Audible/visual alarm To fire dept. connection NOTES: 1. ALL fire protection piping to be installed concealed, unless otherwise noted. 2. Details shown here are typical only. Exact final details and layout shall be as required to suit the facility layout and the requirements of the various regulatory agencies. System drain Main water supply OS&Y gate valve Sleeve, extend min. 1"A.F.F. Alarm check valve Water gauge Flow switch Double check backflow preventer Cap Tee Gas valve Gas supply Union Connect to equipment 3" min.Cap Tee Gas valve Gas supply Union Connect to equipment 3" min.Finished floor Condensate pipe. See plumbing plans for size. Drain box 2" Stand pipe 11 4"Vent min. 2"Waste 2" P-trapApprox. 36" A.F.F.Wye for midline connection. 1 8 ell for end of line connection. Air gap to be 1.5x condensate pipe diameter. Wye fitting Condensate piping Condensate piping Condensate piping 90° ell 45° ell Do Not Use Vertical pipe drop out of bottom of horizontal pipe Vertical pipe rise out of top of horizontal pipe Gas shutoff valve Freeze proof hose bibb (FPHB) Floor drain (FD) or Roof drain (RD) Shutoff valve in pipe 90° Elbow down (drop in pipe) 90° Elbow up (rise in pipe) Clean out in floor CO Sanitary below grade or slab (W) Storm below grade or slab (S) Storm above grade or slab (S) Low pressure gas piping (G) Vent piping (V) Plumbing Symbols and Abbreviations Cold water piping (CW) Sanitary above grade or slab (W) Hot water return piping (HWR) Balancing valve in pipe Check valve in pipe Hot water piping (HW)DRAWING TITLESEALSHEETPROJECT INFOREVISIONS22030 12-12-2022 # DESCRIPTION DATE 100% REVIEW ARCHITECTCLIENTPROJECTAddition &Renovations toOzwell FitnessCONSULTANT1077 3rd Avenue SW,Carmel INOZWELLfitnessGNIBMULP·LACITCELE·LACINAHCEMRTHEENGINEERINGCOLLABORATIV E P601PLUMBINGSCHEDULES &DETAILSSCALE: NTS01 WATER HEATER DETAIL SCALE: NTS02 VERTICAL FIRE RISER SCALE: NTS03 ROOF DRAIN DETAIL SCALE: NTS04DRAIN BOX DETAIL SCALE: NTS05 CONDENSATE TEE DETAIL SCALE: NTS06GAS DIRT LEG DETAIL 02/20/23