HomeMy WebLinkAboutC805 - WATER CONSTRUCTION DETAILSio J a z z_ C] C] m COLLAR ;RADE-- 2REL---- 3ARREL TED '-6" WOOD JG HYLENE� 'SI CONC. - BLOCK SIDE VIEW 0 Ld TRENCH WIDTH FRONT VIEW GATE VALVE BOX SETTING TEES, PLUGS & HYDRANTS TEES, PLUGS & HYDRANTS PIPE DIA. BEARING AREA INCHES "A" FEET SQUARE FEET 4 2.0 1.5 6 2.0 2.9 8 2.5 4.8 10 2.5 7.1 12 3.0 10.0 16 3.0 17.1 18 3.5 21.0 20 4.0 26.0 NOTES: NO SCALE F I RNAN ELBOWS PIPE DIA. BEARING AREA "A" FEET INCHES 90° 45° 22-112° 11-1/4° 4 1.5 2.1 1.1 0.6 0.3 6 2.0 4.1 2.2 1.1 0.6 8 2.0 6.8 3.7 1.9 0.9 10 2.5 10.1 5.5 2.8 1.4 12 3.0 14.1 7.6 3.9 2.0 16 3.0 24.2 13.0 6.7 3.3 18 3.0 30.0 16.3 8.3 4.2 20 3.0 36.8 19.9 10.1 5.1 1. THRUST BLOCK SHALL BE fc=2500 PSI @ 28 DAYS (SEE SPECIFICATIONS SECTION 03300) 2. ALL THRUST BLOCKS SHALL BE POURED AGAINST UNDISTURBED EARTH. 3. BOLTS, FITTINGS & JOINTS SHALL BE KEPT CLEAR OF CONCRETE. 4. A BEARING CAPACITY OF 2000# PER FOOT WAS USED IN DETERMINING THE MINIMUM "BEARING AREAS" IN THE ABOVE TABLES. 5. THE CROSS SECTION OF THE THRUST BLOCKS SHALL BE SQUARE. CONCRETE THRUST BLOCK DETAIL NO SCALE New Pipe Shall Be Existing Water Main Installed Under The Topping Sleeve Existing Water Main See Trench Detail For Backfill Requirements tVG/VeVGI Existing Water Main New Water Main Varies � vvvvvvvvvvv vvvvvvvvvvv• 12" Min j vvvvvvvvvvv vvvvvvvvvv i Tee vvvvvvvvvvv vvvvv New Water Main vvv vvvv vvv ' vvv vvv Bend \ vvv vvvv As Required 9 I/ories vvvvv vvvv vvv vvvvvv Bed Pipe In Specified Granular Bedding Material Hand Tamped In Note: All Joints Shall Be 6" Layers To Pipe Centerline Restrained Except Bedding Material Shall Conform In Run Of Tee. To INDOT 903.02, Size No. 8 PLAN SECTION Notes: 1) Megalug flanges shall be used for all mechanical joints. 2) Bell end pieces of pipe 4 ft. and smaller shall be considered TITLE: scrap, and shall not be installed into system. CITY OF C A R M E L WATER VAIN STANDARD DETAILS CONNECTION DETAIL Drawn By: Date: March 2001 Scale: Not To Scale Jones & Henry Drawing Name: CW5 Engineers, Inc. SIZE "W" Ll "** "T" 6" 2'-6" 2'-0" 4" 8„ 2,-6„ 2,-1- 4„ 10" 2'-6" 2'-3" 4" 12" 2,_9" 2,_5" 4"" 15 3'-0" 2'-8" 5" 18 3'-6" 3'-0" 5" 21 " 3'-11 " 3'-4" 6" 24" 4'-3" 3'-8" 6" 27" 5'-6" 3'-11„ 6» 30 5'-9" 4'-4" 6" 36 6'-3" 5'-2" 6" 42 6'-11" 8» 48" 7'-4" 9" 54" 8,-0„ 9„ 60" 8'-6" 9" 66" 9'-1" g" 72" 9-8 10» 10 78" 10'-3" loll 1'-0" Minimum Undisturbed Ground Match Existing Pavement Material And Thickness Existing Pavement, Saw Cut Straight Edge Approved Excavated Material In Unpaved Areas Unless Otherwise Directed Special Back/ill Under Pavement, Drives, Walks Or Where Ordered Tamped In 6" Layers Special Backfill Shall Conform To INDOT 211.02b TRENCH SCHEDULE Note: Under Existing Sewers, Water Lines, Gas Lines, Telephone Cable And % o Electrical Conduits, Backfill With Granular Bedding Material To The Centerline Of The Existing Utility Lines. Undisturbed Earth "W" or 'U" At Top Of Pipe ~ *Note.' "W" Is The Maximum Width For Rigid Pipes. "U" Is The Minimum Width For Flexible Pipes In Accordance With ASTM D-2321. ** Table is For ASTM D-3034, Wall Thickness Class SDR 35 For 6 "-15" And AST" F-679 Wall Thickness Class T-1 For 18"-36. For Other Flexible Pipes, Minimum Trench Width 'U" Shall Meet Manufacturers Requirements. TRENCH DETAIL FOR WATER LINES - NOT TO SCALE For Flexible Pipe With Solid Or Profile Walls, Granular Bedding Material Shall Be Placed And Hand Tamped In 6" Layers To A Minimum Of 1 "-O" Above Pipe. Bed Pipe In Specified Granular Bedding Material Hand Tamped In 6"" foyers to 8 to 12 inches above pipe. Bedding Material Shall Conform To INDOT 903.02, Size No. 8 Final backfill for water mains, water service laterals, sanitary mains and sanitary service laterals for all installations within the City right-of-way shall be B-Borrow for Structure Backfill meeting the material requirements of the WDOT The material shall be apporoved by the City of Carmel Department of Engineering at time of installation. Final bockfill shall be compacted in 6-inch maximum lifts to not less than 95Z Standard Proctor Density for the entire depth of the material placed. The bockfill for the top 6-inches of the excavation below the start of the aggregate sub -base of the pavement shall be No. 53 Stone meeting the material requirements of the INDOT and shall be compacted to not less than 957 Standard Proctor Density. If the standard practice of the utility that has jurisdiction over the installation has a more stringent final backrill requirement, the more stringent requirement shall govern. PRESSURE PIPE JOINT RESTRAINT TABLE Length Of Pipe To Be Restrained In Each Direction From ? Of Bend Based On 150 PSI Test Pressure Degree Of Bend 6" 8" loll 12" 14" 161, 18" 20" 24" Jo 90" Tees 27' J5' 42' 50' 58' 65' 7J' 80, 95' 115' & Plugs 45- 7' 9' 11, 13' 15' 17' 19' 21 ' 24' 29' 22-1/2- 3' 4' 5' 6' 7' 8' 9' 10' 12' 14' 11-1/4" 2' 2' 3' 3' 4' 4' 4' 5' 6' 7' Restrained Joints Shall Be Mechanical Joint With Retainer Glands, US Pipe TR Flex Joint System, US Pipe Field LOK Gasket System, Or Equal. NOTE.- THE ABOVE RESTRAINED JOINT LENGTHS ARE MINIMUM LENGTHS THE DESIGN ENGINEER SHALL DETERMINE IF LONGER LENGTHS ARE REQUIRED. CIRCLE DESIGN GROUP INDIANAPOLIS, IN 1 317,781.6200 C I RCLEDESIGNGROUP.COM Engineer: \�pp\ 111111111111I llllll/ °gip ............ 910023 STATE OF .ram Off• / �v //'/I �lllllllll I I I 1 Y KEY PLAN CARMEL CITY CENTER SCALE: NTS PLAN (NORTH Developer: P E D C O R a' aew&x DEVELOPMENT CO. COPYRIGHT & OWNERSHIP OF DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. m COPY RIGHT 2015 JAMES R. STUTZMAN, AIA, Carmel, Indiana. CONSTRUCTION DOCUMENTS Set Issue Date Sheet Issue Date 06/30/21 Drawn By Checked By DBH RDM Last Revision Date: Sheet Title: WATER CONSTRUCTION DETAILS Sheet Number: C805