Loading...
HomeMy WebLinkAboutC4.0 GRADING PLAND D D D D D D D DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD D D D D D D D 1-STY BRICK AND FRAME COMMERCIAL BUILDING C C C C C C C C C C C C C C C CCC C 6" STORM -PREFERREDLOCATION4" FOODWASTE4" SANWASTEGAS SERVICECT CABSTORM DROP FROM ROOF -PREFERRED LOCATIONTHIS AREA IS FOR MENU BOARDS AND OCB ONLY.NO UNDERGROUND GREASE TRAPS OR ABOVEGROUND ELECTRICAL TRANSFORMERS; SEE SITEPLAN FROM CFS.VERIFY ALL UNDERGROUND WORK THIS AREA w/SIGN CONTRACTOR.FIRE PROTECTION 2" WATER SERVICEFDC DIRECT CONNECTIONSFOR VENDORSPICKUP WINDOWSANSANSANSANSANSAN SAN SAN SANSANSANSANSAN G G G GGGGGGGGGGGG E E E E E ECCCCC W WWWWWWWWWWWWFFE = 834.00 STM STM STM ST ST PATIO ST W W WWWWWWWWWWWWSTMSTMSTMFLOOD PLAIN NOTE THE SITE DOES NOT LIE IN A SPECIAL FLOOD HAZARD AREA ZONE ESTABLISHED BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY - NATIONAL FLOOD INSURANCE PROGRAM, WHEN PLOTTED BY SCALE ON FLOOD INSURANCE RATE MAP #18057C0139C DATED NOVEMBER 19, 2014. IMPERVIOUS AREAS EXISTING = 0.52 AC (44.8%) PROPOSED = 0.79 AC (68.3%) C4.0 EXISTING SPOT ELEVATION CURB & GUTTER ELEVATION PAVEMENT SPOT ELEVATION GROUND SPOT ELEVATION ELECTRICAL RISER GUY ANCHOR ELECTRIC JUNCTION BOX STREET LIGHT ELECTRIC MANHOLE ELECTRIC OUTLET UTILITY POLE UTILITY POLE W/ TRANSFORMER TRANSFORMER COMMUNICATIONS JUNCTION BOX COMMUNICATIONS MANHOLE COMMUNICATIONS PEDESTAL RIGHT OF WAY LINE FENCE GUARD RAIL BOUNDARY LINE FIRE HYDRANT POST INDICATOR VALVE WATER MANHOLE SPRINKLER SPIGOT WATER METER WATER VALVE GAS METER GAS VALVE ELECTRIC METER MONITORING WELL TRAFFIC SIGNAL POLE TRAFFIC SIGNAL BOLLARD FLAG POLE PARKING METER POST SIGN PARKING WHEEL STOP DOWN SPOUT ACCESSIBLE SPACE GATE POST COMMUNICATIONS RISER STORM CLEANOUT BEEHIVE INLET CURB INLET FLOOR DRAIN ROUND INLET SQUARE INLET STORM MANHOLE SANITARY SEWER CLEANOUT LIFT STATION SANITARY SEWER MANHOLE HEAVY DUTY ASPHALT STANDARD DUTY ASPHALT ROW RIGHT OF WAY ESMT EASEMENT D.&U.E.DRAINAGE AND UTILITY EASEMENT FFE FINISH FLOOR ELEVATION TC TOP OF CURB GUT GUTTER CMP CORRUGATED METAL PIPE RCP REINFORCED CONCRETE PIPE PVC POLYVINYL CHLORIDE PIPE VCP VITRIFIED CLAY PIPE HDPE HIGH DENSITY POLYETHYLENE PIPE DIP DUCTILE IRON PIPE SSD SUB SURFACE DRAIN PIPE STM STORM SAN SANITARY STR STRUCTURE CO CLEANOUT PAVEMENT GRADING PLAN LEGEND UTILITIES ABBREVIATIONS OTHER LINE TYPES FLOW LINE INDEX CONTOUR INTERMEDIATE CONTOUR SANITARY SEWER MAIN STORM SEWER MAIN UNDERGROUND GAS UNDERGROUND WATER AERIAL ELECTRIC UNDERGROUND ELECTRIC UNDERGROUND COMMUNICATIONS AERIAL COMMUNICATIONS OVERHEAD UTILITY FORCE MAIN G G G W W E(A)E(A) E E E C C C C(A)C(A) OHU OHU FM FM AERIAL FIBER OPTIC CABLEFO(A)FO(A) UNDERGROUND FIBER OPTICFOFO EMERGENCY FLOOD ROUTE SANITARY SEWER LATERALSANSAN ROOF DRAINSTMSTM SUB SURFACE DRAIN GRADE BREAK LINE FLOW DIRECTION AND SLOPE GRADING PLANBENCHMARK DATA REFER TO SHEET C0 - TITLE SHEET FOR BENCHMARK DATA. STORM SEWER DATA REFER TO SHEET C5.0 - UTILITY PLAN FOR DETAILED STORM STRUCTURE AND PIPE INFORMATION. ALL PROPOSED STORM SEWERS ARE A PRIVATE STORM SEWER SYSTEM.REVISIONS AND ISSUESPREPARED FOR:PROJECT NO. SHEET NO.CHECKED BY:DRAWN BY:DEGDESIGNED BY:DWG NAME:PROJECT NO.:W220058DATEBY01.31.2022BTDATE:DEGSTEVEN SCOTT RUCKER P.E. 11300279ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SMA PART OF THE SOUTHWEST QUARTER, SECTION 31, TOWNSHIP 18 NORTH, RANGE 4 EAST, HAMILTON COUNTY, INDIANAW22.0058431 E CARMEL DRIVE, CARMEL, IN 46032Know what's below. before you dig.Call R CULVER'SCARMEL, INW S N E 04.29.2022DEGTAC COMMENT REVISIONS105.13.2022AMQLANDSCAPE COMMENT REVISIONS206.24.2022BTREMOVE PARKING ISLAND AND TRANSFORMER3TAC COMMENT REVISIONS 2407.07.2022DEGWQ TREATMENT TRAIN & WATER COMMENTS508.12.2022DEGADDED FIRE HYDRANT & FDC AND DRY LINE608.25.2022DEGRELOCATED IRRIGATION VALVE & METER709.29.2022DEGSWPPP2 UPDATE TO CLARIFY WQ UNIT & EASEMENT810.06.2022DEGCRE REVIEW COMMENT REVISIONS910.24.2022DEGADDED SURVEY DATA FOR EAST ADJOINER1011.23.2022DEGPONDING LIMITS EMERGENCY OVERFLOW DEPTH = 0.50' ELEVATION = 832.30 DEPTH = 0.22' ELEVATION = 831.22 UNDERGROUND DETENTION SYSTEM TOP OF STONE - 830.63 TOP OF CHAMBER - 829.63 BOTTOM OF CHAMBER - 827.10 BOTTOM OF STONE BASE - 826.60 DETENTION VOLUME = 4,670 CUFT DRAINAGE ANALYSIS DRAINAGE AREA = 1.16 Ac ALLOWABLE RELEASE RATES Q10post ≤ Q2pre = 2.90 cfs Q100post ≤ Q2pre = 4.35 cfs PROPOSED DISCHARGE RATES 2-YEAR = 1.74 10-YEAR = 2.88 100-YEAR = 4.33 DETENTION VOLUME REQUIRED = 5,105 PROVIDED = 5,640 DEPTH = 0.60' ELEVATION = 832.30 LIMITS OF DISTURBANCE FLOOD PROTECTION 100-YEAR STAGE ELEVATION = 830.09 EMERGENCY OVERFLOW WEIR = 830.25 MINIMUM LOWEST ADJACENT GRADE MLAG = 832.25 NEAREST FLOODWAY = CARMEL CREEK APPROXIMATELY 0.5-MILES OFF-SITE NEAREST BASE FLOOD ELEVATION = 813 MINIMUM FLOOD PROTECTION GRADEMFPG = 833.40 CONCRETE PAVEMENT BUILDING AREA DEPTH = 0.21' ELEVATION = 831.10