HomeMy WebLinkAboutC5.0 UTILITY PLAN1-STY BRICK AND FRAME COMMERCIAL BUILDING C C C C C C C C C C C C C C C CCC C 6" STORM -PREFERREDLOCATION4" FOODWASTE4" SANWASTEGAS SERVICECT CABSTORM DROP FROM ROOF -PREFERRED LOCATIONTHIS AREA IS FOR MENU BOARDS AND OCB ONLY.NO UNDERGROUND GREASE TRAPS OR ABOVEGROUND ELECTRICAL TRANSFORMERS; SEE SITEPLAN FROM CFS.VERIFY ALL UNDERGROUND WORK THIS AREA w/SIGN CONTRACTOR.FIRE PROTECTION 2" WATER SERVICEFDC DIRECT CONNECTIONSFOR VENDORSPICKUP WINDOWSANSANSANSANSANSAN SAN SAN SANSANSANSANSAN SANITARY CO TC = 833.06 INV = 829.65 31' OF 6" PVC @ 1.1% SANITARY CO TC = 832.42 INV = 828.33 ASSUMED INV = ±825.40 CONTRACTOR TO FIELD VERIFY SANITARY CO TC = 832.47 INV = 826.30 3' OF 6" PVC @ 1.1% 3' OF 6" PVC @ 1.1% SANITARY CO TC = 833.94 INV = 830.00 SANITARY CO TC= 833.72 INV = 830.00 84' OF 6" PVC @ 1.1% 75' OF 6" PVC @ 2.7% 42' OF 6" PVC @ 1.1% G G G GGGGGGGGGGGG E E E E E ECCCCC SANITARY CO TC = 833.28 INV = 829.26 GREASE TRAP INV IN = 829.60 INV OUT = 829.35 31' OF 6" PVC @ 2.4% 5' OF 6" PVC @ 1.1% 8' OF 6" PVC @ 1.1% W WWWWWWWWWWWWFFE = 834.00 STM STM STM ST ST PATIO ST SANITARY CO TC = 831.23 INV = 825.84 PROPOSED BMP EASEMENT PROPOSED BMPEASEMENTPROPOSED BMPEASEMENT40' OF 6" PVC @ 1.1% W W WWWWWWWWWWWWSTMSTMSTM822 825 830 835 822 825 830 835 -0+100+000+250+500+751+001+251+501+752+002+252+502+753+003+253+503+60PROPOSED 6" PVC INV = 825.93 PROPOSED GAS PROPOSED 1" PVC C900 IRRIGATION LINE PROPOSED 6" PE DOMESTIC SERVICE LINE CONCRETE CRADEL STORM SEWER STRUCTURE DATA TABLE STRUCTURE NUMBER DETENTION EX. 100 WQ 101 102 103 104 105 106 TOP OF CASTING 828.86 831.18 831.35 833.30 831.58 831.32 831.00 831.70 831.83 STRUCTURE TYPE NULL STRUCTURE 48'' DIA. MANHOLE AQUA-SWIRL XC-3 48'' DIA. MANHOLE 48'' DIA. MANHOLE 48'' DIA. MANHOLE 48'' DIA. MANHOLE PAVED INLET, 22 X 22 PAVED INLET, 22 X 22 CASTING TYPE SOLID R-1772 SOLID R-1772 R-1772 R-1772 R-3357-A R-3405 R-3405 INVERT INV IN (E)= 827.10 (18" HDPE) INV OUT (W)= 827.10 (18" HDPE) INV IN (SE)= 826.44 (12" RCP) INV IN (SW)= 827.37 (12" HDPE) INV OUT (NW)= 827.27 (12" HDPE) INV IN (E)= 826.60 (18" HDPE) INV OUT (NW)= 826.60 (12" RCP) INV IN (SE)= 827.27 (12" HDPE) INV IN (S)= 827.37 (18" RCP) INV OUT (W)= 827.17 (18" HDPE) INV IN (SE)= 827.57 (18" RCP) INV OUT (NE)= 827.47 (12" HDPE) INV OUT (N)= 828.52 (18" RCP) INV IN (S)= 827.75 (15" RCP) INV OUT (NW)= 827.65 (18" RCP) INV IN (W)= 828.50 (12" RCP) INV OUT (N)= 828.40 (15" RCP) INV OUT (E)= 828.80 (12" RCP) SUMP= 824.60 SUMP= 825.37 SUMP= 825.47 CHAMBERMAXX N / A N / A STORM SEWER PIPE DATA TABLE UPSTREAM STRUCTURE 101 101 102 103 103 104 105 105 WQ DOWNSTREAM STRUCTURE DETENTION EX. 100 WQ 102 103 106 104 102 SIZE 18" 12" 18" 12" 18" 18" 12" 15" 12" MATERIAL HDPE RCP HDPE HDPE RCP RCP RCP RCP HDPE LENGTH 16' 25' 8' 10' 14' 31' 93' 202' 9' SLOPE 3.06% 0.63% 0.85% 0.97% 8.48% 0.26% 0.32% 0.32% 0.00% DETENTION UTILITY PLAN NOTES SANITARY SEWER NOTES CONNECT PROPOSED 6" [SDR-35 PVC] SANITARY SEWER LATERAL TO EXISTING SANITARY SEWER 8" MAIN. COORDINATE CONNECTION WITH MEP. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY INVERT & COORDINATE WITH ENGINEER IF DESIGN VARIES. PROVIDE CLEANOUTS AS REQUIRED/SHOWN. VERIFY INVERTS ON EXISTING LINE AND COORDINATE CONDITIONS WITH MEP. ADJUST AS REQUIRED COORDINATE CONNECTION OF 6" SDR-35 PVC SANITARY SEWER LATERAL WITH PLUMBING DRAWINGS. EXISTING 8" SANITARY SEWER PROPOSED SANITARY LATERAL CLEANOUT TYPE 2 (OUTSIDE 3' OF BUILDING). REFER TO DETAIL ON SHEET C8.2 GREASE TRAP PER CITY OF CARMEL SPECS. REFER TO DETAIL ON SHEET C8.2 PROPOSED SANITARY LATERAL CLEANOUT TYPE 1 (WITHIN 3' OF BUILDING). REFER TO DETAIL ON SHEET C8.2 WATER SERVICE NOTES: COORDINATE AND CONNECT 6" PVC C900 WATER SERVICE LINE TO EXISTING 12" DI WATER MAIN. TAPPING SLEEVE AND VALVE REQUIRED COORDINATE CONNECTION OF 2" PE DOMESTIC SERVICE LINE AND 6" FIRE SERVICE LINE WITH PLUMBING DRAWINGS. COORDINATE CONNECTION OF DOMESTIC 1.5" METER AND BACKFLOW PREVENTOR LOCATION WITH MEP PLANS - TO BE INSIDE BUILDING. EXISTING 12" DI WATER MAIN N/A CONNECT EXISTING 1" LINE TO PROPOSED IRRIGATION VALVE AND 3/4" METER POST INDICATOR VALVE 6" X 2" TEE 6" X 6" TEE PROPOSED FIRE HYDRANT PRIVATE AND PAINTED RED FROM FACTORY PROPOSED FIRE DEPARTMENT CONNECTION [5" STORZ] 4" FIRE SUPPRESSION DRY LINE ELECTRIC NOTES: CONNECT BUILDING ELECTRICAL LINE TO EXISTING POWER SUPPLY. COORDINATE CONNECTION WITH POWER COMPANY AND ELECTRICAL DRAWINGS. ADJUST AS REQUIRED. PROPOSED TRANSFORMER PAD MOUNTED. COORD W LOCAL ELECTRIC CO. BUILDING ELECTRICAL LINE POINT OF CONNECTION. COORDINATE CONNECTION WITH MEP AND ELECTRICAL DRAWINGS. ADJUST AS REQUIRED. COMMUNICATION NOTES: COORDINATE CONNECTION OF COMMUNICATION SERVICE LINES TO EXISTING UTILITY PEDESTAL. COORDINATE AND CONNECT BUILDING COMMUNICATION SERVICE LINE(S) TO CONNECTION POINT AS SHOWN. ADJUST AS REQUIRED. 4" PVC CONDUIT TO BE INSTALLED WITH PULL STRINGS. GAS SERVICE NOTES: CONNECT PROPOSED GAS SERVICE TO EXISTING GAS SERVICE LINE. REFER TO PLUMBING DRAWINGS AND COORDINATE WITH VECTREN. REMOVE EXISTING LINE PAST POINT OF CONNECTION. PROPOSED GAS METER LOCATION. REFER TO PLUMBING DRAWINGS AND COORDINATE WITH VECTREN. STORM SEWER NOTES: 6" BUILDING ROOF DRAIN TO BE DOUBLE WALL HANCOR HI-Q OR EQUIVALENT. REFER TO ARCHITECTURAL PLANS FOR CONNECTION INSIDE BUILDING 3" CANOPY ROOF DRAIN (DOUBLE WALL HANCOR HI-Q OR EQUIVALENT) STRUCTURE TO BE MOUNTED WITH AQUA-SWIRL AQUA-GUARDIAN CATCH BASIN INSERT. REFER TO DETAIL ON SHEET 8.3 WATER QUALITY DIVERSION STRUCTURE - REFER TO DETAIL ON SHEET C8.3 AQUA-SHIELD XCELERATOR XC-3 - REFER TO DETAIL ON SHEET C8.4 UNDERGROUND DETENTION - REFER TO DETAILS ON SHEET C8.4 OUTLET CONTROL STRUCTURE - REFER TO DETAIL ON SHEET C8.3 GENERAL NOTES: MAINTAIN 10' HORIZONTAL AND 18" VERTICAL SEPARATION BETWEEN STORM / SANITARY SEWER SYSTEMS AND DOMESTIC / FIRE LINE SERVICE - OTHERWISE, CONCRETE CRADEL IS REQUIRED. SANITARY SEWER LINE IN CLOSE PROXIMITY OF WATER LINE SHALL BE C900 WATER MAIN GRADE PVC. W4 W2 W3 SS3 SS2 W1 SS4 E1 E2 C1 G1 SS1 W5 C5.0UTILITY PLANELECTRICAL RISER GUY ANCHOR ELECTRIC JUNCTION BOX STREET LIGHT UTILITY POLE UTILITY POLE W/ TRANSFORMER TRANSFORMER COMMUNICATIONS JUNCTION BOX COMMUNICATIONS MANHOLE COMMUNICATIONS PEDESTAL RIGHT OF WAY LINE FIRE HYDRANT WATER MANHOLE SPRINKLER CONTROL VALVE WATER METER WATER VALVE GAS METER GAS VALVE ELECTRIC METER BOLLARD FLAG POLE PARKING METER POST SIGN PARKING WHEEL STOP DOWN SPOUT ACCESSIBLE SPACE GATE POST STORM CLEANOUT BEEHIVE INLET CURB INLET FLOOR DRAIN ROUND INLET SQUARE INLET STORM MANHOLE SANITARY SEWER CLEANOUT SANITARY SEWER MANHOLE PARKING LOT LIGHT (1 HEAD) PARKING LOT LIGHT (2 HEAD) FFE FINISH FLOOR ELEVATION CMP CORRUGATED METAL PIPE RCP REINFORCED CONCRETE PIPE PVC POLYVINYL CHLORIDE PIPE VCP VITRIFIED CLAY PIPE HDPE HIGH DENSITY POLYETHYLENE PIPE DIP DUCTILE IRON PIPE SSD SUB SURFACE DRAIN PIPE STM STORM SAN SANITARY STR STRUCTURE CO CLEANOUT UTILITY PLAN LEGEND UTILITIES ABBREVIATIONS OTHER LINE TYPES SANITARY SEWER MAIN STORM SEWER MAIN UNDERGROUND GAS UNDERGROUND WATER UNDERGROUND ELECTRIC G G G W W E E E C C C UNDERGROUND FIBER OPTICFOFO SANITARY SEWER LATERALSANSAN ROOF DRAINSTMSTM SUB SURFACE DRAIN C2 G2 W6 W7 POST INDICATOR VALVE REVISIONS AND ISSUESPREPARED FOR:PROJECT NO. SHEET NO.CHECKED BY:DRAWN BY:DEGDESIGNED BY:DWG NAME:PROJECT NO.:W220058DATEBY01.31.2022BTDATE:DEGSTEVEN SCOTT RUCKER P.E. 11300279ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SMA PART OF THE SOUTHWEST QUARTER, SECTION 31, TOWNSHIP 18 NORTH, RANGE 4 EAST, HAMILTON COUNTY, INDIANAW22.0058431 E CARMEL DRIVE, CARMEL, IN 46032Know what's below. before you dig.Call R CULVER'SCARMEL, INW S N E 04.29.2022DEGTAC COMMENT REVISIONS105.13.2022AMQLANDSCAPE COMMENT REVISIONS206.24.2022BTREMOVE PARKING ISLAND AND TRANSFORMER3TAC COMMENT REVISIONS 2407.07.2022DEGWQ TREATMENT TRAIN & WATER COMMENTS508.12.2022DEGADDED FIRE HYDRANT & FDC AND DRY LINE608.25.2022DEGRELOCATED IRRIGATION VALVE & METER709.29.2022DEGSWPPP2 UPDATE TO CLARIFY WQ UNIT & EASEMENT810.06.2022DEGCRE REVIEW COMMENT REVISIONS910.24.2022DEGADDED SURVEY DATA FOR EAST ADJOINER1011.23.2022DEGSS3 N1 SS5 NOTE: FULL DEPTH GRANULAR BACKFILL REQUIRED FOR SANITARY, WATER, STORM LINES UNDER PAVEMENT. TRACER WIRE TO BE LAID ALONG SANITARY, WATER, STORM LINES. ST1 ST2 SS3SS1 SS4 SS4 SS4 SS4 SS5 SS6 W1 W2 SS6 SS2 SS2 W3 W3 W5 W7 E1 E3 C1 C2 G1 G2 ST1 ST1 ST3 ST2 ST2 N1 UNDERGROUND COMMUNICATIONS ST3 ST6 ST4 ST5 ST6 ST7 ST7 ST4 ST5 10-YR HGL 10-YR HGL 10-YR HGL 100-YR HGL 100-YR HGL 100-YR HGL E3 E2 W6 ST3 ST3 N2 SS4 FINISHED GRADE EXISTING GRADE PROFILE LEGEND HYDRAULIC GRADE LINE N1 N1 N2 W8 W8 W9 W9 W10 W10 W11 W11 W11