Loading...
HomeMy WebLinkAboutTRUSS LAYOUTS2X8 LEDGER BOARDATTACHED TO 2ND FLOOR WALLSET B02 & B03 ON TOPOF FLOOR TRUSS GIRDER2X8 LEDGER BOARDATTACHED TO 2ND FLOOR WALLDO NOT SET TRUSSIN ATTIC ACCESS SPACEA01A04B01B03B05B06C01C02C02B03V19V20V21V22V23V24V25V26V27V28V08V01V02V03V04V05V06V07V09V10V11V12V13V14V15V16V17V18Undesigned(4) A02(13) A03(5) B02(10) B045-07-081-04-0820-03-0817-11-009-04-00 10-00-008-00-0026-08-0015-00-0419-07-1220-02-00D01D03(17) D02Truss Connector Total ListManuf Product QtyIMPORTANTTHIS DRAWING IS FOR FIELD PLACEMENT OF INDIVIDUALCOMPONENTS ONLY, AND DOES NOT CONSTITUTE ANENGINEERED DOCUMENT.NOTEPROPER BEARING AND BEARING DESIGN INCLUDINGANCHORAGE, IS THE RESPONSIBILITY OF THE BUILDINGDESIGNER, ARCHITECT AND / OR BUILDING ENGINEER. REFERTO INDIVIDUAL TRUSS DESIGNS FOR REACTIONS, MINIMUMREQUIRED BEARING SIZE, UPLIFT, AND ADDITIONAL LOADS.84 COMPONENTS DOES NOT ASSUME RESPONSIBILITY INTHESE AREAS OF CONCERN.BRACINGERECTION, TEMPORARY, AND PERMANENT BRACING IS THERESPONSIBILITY OF THE CONTRACTOR AND / OR BUILDINGDESIGNER. REFER TO INDIVIDUAL TRUSS DESIGNS FORADDITIONAL BRACING REQUIREMENTS. REFER TO BCSI-B1SUMMARY SHEET. THE STRUCTURAL BUILDING COMPONENTSASSOCIATION COMMENTARY, AND RECOMMENDATIONS FORHANDLING, INSTALLING & BRACING METAL PLATE CONNECTEDWOOD TRUSSES.www.sbcindustry.comINSTALLATIONDO NOT CUT, DRILL, OR ALTER TRUSSES. ANY QUESTIONSCALL 84 COMPONENTS. PROPER INSTALLATION, ANDHANDLING OF COMPONENTS IS THE RESPONSIBILITY OF THEERECTING CONTRACTOR. 84 COMPONENTS MUST BENOTIFIED OF ANY PROBLEMS, AND AFFORDED THEOPPORTUNITY TO REVIEW, AND MAKE NECESSARYCORRECTIONS, OR NO BACK CHARGES WILL BE ACCEPTEDOR APPROVED.WARNINGWARNINGS, AND INSTRUCTIONS FOR ERECTIONOF COMPONENTS ARE INCLUDED IN THE DELIVERY PACKAGE.KEEP THIS INFORMATION ON THE JOB SITE. THESEDOCUMENTS WILL ALSO BE NEEDED FOR JOB SITEINSPECTION. MISUSE AND IMPROPER INSTALLATION OFCOMPONENTS MAY RESULT IN FAILURE, BODILY INJURY, LOSSOF PROPERTY, AND / OR LIFE.Roof Area:Overhang Length:Eave Length:Hip Length:Valley Length:Ridge Length:SHEET NUMBER:R1.1Roof TrussPlacement PlanSCALE: NTSJob#: A00340PO#:Date: 1/24/2023Drawn By: NBMDesigned By: NBMChecked By:ROOF LOADS:TCLL: 25.0 lb/ft²TCDL: 10.0 lb/ft²BCLL: 0.0 lb/ft²BCDL:10.0 lb/ft²Building Code: IRC 2018Wind Speed: 115 mphOn-Center Spacing: 24" U.N.O.2131.38 SF67.94 LF215.37 LF0 LF104.13 LF43.27 LFROOFDATATHIS LAYOUT IS INTENDED FOR THE PURPOSE OF TRUSS LOCATION ANDPLACEMENT ONLY. REFER TO THE BUILDING PLANS FOR ACTUAL BUILDING CONSTRUCTION.DREES AAV-14BLUCERNE & ZURICH, ,ROOF TRUSS PLACEMENT PLANA003401850 N Graham RoadFranklin, Indiana 46131Office:(317) 346-4274Fax: (317) 346-0916