HomeMy WebLinkAboutA010 - Front ElevationãBRICK VENEER LINTEL SCHEDULE
HEIGHT OF VENEERSPAN
ALL LINTELS <=6' SHALL HAVE 4" MINIMUM BEARING AT EACH END.
ALL LINTELS >=6' SHALL HAVE 8" MINIMUM BEARING AT EACH END.
* FASTENED TO HDR @ 1/3 SPAN POINTS THRU 1-1/2" LONG VERTICALLY SLOTTED HOLES IN LINTEL w/
1/2" DIA. x 3-1/2" LONG LAG SCREWS. LOCATE LAG SCREWS @ MIDDLE OF SLOTTED HOLE & TIGHTEN
SCREWS ENOUGH TO ALLOW MOVEMENT OF LINTEL.
***ANY LINTEL CONDITION NOT SPECIFIED ABOVE SHALL BE DESIGNED
STEEL ANGLE SIZE
Up to 3'-6"
Up to 6'-0"
Up to 8'-0"
9'-0"
*16'-0"
12 FT. MAX
ABOVE LINTEL
*16'-0"
L3-1/2 x3-1/2 x1/4
3 FT. MAX
4-1/2 FT. MAX
20 FT. MAX
20 FT. MAX
20 FT. MAX
L5x 3-1/2x 5/16 (LLV)
L6x 3-1/2x 3/8 (LLV)
L7x 4x 3/8 (LLV)
L8x 4x 1/2 (LLV)
L7x 4x 3/8 (LLV)
TYPICAL TRIM:
6" FASCIA
8" FRIEZE
(ALL SIDES)
(FRONT ONLY, UNLESS OTHERWISE NOTED)
ZURICH
UNIT A
ZURICH
UNIT A
GENEVA
UNIT B
GENEVA
UNIT B