Loading...
HomeMy WebLinkAboutAVV 15 - FLOOR LAYOUT - A00201 DREES AAV15 FL LO CIFT03FT02FT01FT06FT11FT10FT07FT23FT16FT14FT13FT13FT24FT17FT12(3) FT05(6) FT08(5) FT04(3) FT09(6) FT22(3) FT21(4) FT19(3) FT15(2) FT20(2) FT1818-00-0810-00-006-07-083-06-0016-05-0015-11-0014-02-0834-08-0016-05-00 3-06-00 14-09-004-02-00 12-02-004-02-086-121-07-082-11-0014-00-008-00-004-09-041-07-001-08-141-07-031-07-031-07-039-071-07-031-07-031-07-031-07-031-07-031-00-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-09-021-05-041-07-031-07-031-07-031-07-031-07-0310-051-07-031-07-031-07-031-06-077-1111-111-08-149-071-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-00-0316-11-0024-04-0815-03-0034-08-0034-08-0017-02-0820-05-0031-04-0818-03-00Truss Connector Total ListManuf Product QtyDREES AAV-15ZURICH AND GENEVA1850 N Graham RoadFranklin, Indiana 461312nd Floor Truss Placement PlanA00201IMPORTANTTHIS DRAWING IS FOR FIELD PLACEMENT OF INDIVIDUALCOMPONENTS ONLY, AND DOES NOT CONSTITUTE ANENGINEERED DOCUMENT.NOTEPROPER BEARING AND BEARING DESIGN INCLUDINGANCHORAGE, IS THE RESPONSIBILITY OF THE BUILDINGDESIGNER, ARCHITECT AND / OR BUILDING ENGINEER. REFERTO INDIVIDUAL TRUSS DESIGNS FOR REACTIONS, MINIMUMREQUIRED BEARING SIZE, UPLIFT, AND ADDITIONAL LOADS.84 COMPONENTS DOES NOT ASSUME RESPONSIBILITY INTHESE AREAS OF CONCERN.BRACINGERECTION, TEMPORARY, AND PERMANENT BRACING IS THERESPONSIBILITY OF THE CONTRACTOR AND / OR BUILDINGDESIGNER. REFER TO INDIVIDUAL TRUSS DESIGNS FORADDITIONAL BRACING REQUIREMENTS. REFER TO BCSI-B1SUMMARY SHEET. THE STRUCTURAL BUILDING COMPONENTSASSOCIATION COMMENTARY, AND RECOMMENDATIONS FORHANDLING, INSTALLING & BRACING METAL PLATE CONNECTEDWOOD TRUSSES.www.sbcindustry.comINSTALLATIONDO NOT CUT, DRILL, OR ALTER TRUSSES. ANY QUESTIONSCALL 84 COMPONENTS. PROPER INSTALLATION, ANDHANDLING OF COMPONENTS IS THE RESPONSIBILITY OF THEERECTING CONTRACTOR. 84 COMPONENTS MUST BENOTIFIED OF ANY PROBLEMS, AND AFFORDED THEOPPORTUNITY TO REVIEW, AND MAKE NECESSARYCORRECTIONS, OR NO BACK CHARGES WILL BE ACCEPTEDOR APPROVED.WARNINGWARNINGS, AND INSTRUCTIONS FOR ERECTIONOF COMPONENTS ARE INCLUDED IN THE DELIVERY PACKAGE.KEEP THIS INFORMATION ON THE JOB SITE. THESEDOCUMENTS WILL ALSO BE NEEDED FOR JOB SITEINSPECTION. MISUSE AND IMPROPER INSTALLATION OFCOMPONENTS MAY RESULT IN FAILURE, BODILY INJURY, LOSSOF PROPERTY, AND / OR LIFE.Floor Area:Floor Sheathing:SHEET NUMBER:F2.1Floor TrussPlacement PlanSCALE:NTSJob#: A00201PO#:Date: 12/9/2022Drawn By: NBMChecked By:FLOORLOADS:40-10-10On-Center Spacing: 19.2" U.N.O.1138.22 SF40.9 SheetsFLOORDATA1850 N. Graham RoadFranklin, Indiana 46131Phone: (317) 346-4274