Loading...
HomeMy WebLinkAboutGADDY220532WBIN-plotLayout Name 220532WBIN Description GADDY RES Created December 14, 2022 Revised December 14, 2022 Builder CARTER NOBLESVILLE Dealer Sales Rep TIM Designer Ground Floor Floor Truss Label Description Width Depth Qty Plies Pcs Length B28 OJ314 2.5 16 1 12-0-0 B25 OJ314 2.5 16 1 10-0-0 B26 OJ314 2.5 16 1 10-0-0 J5 OJ314 2.5 16 10 16-0-0 J15 OJ314 2.5 16 4 16-0-0 J14 OJ314 2.5 16 6 12-0-0 J12 OJ314 2.5 16 17 10-0-0 J18 OJ314 2.5 16 3 10-0-0 J10 OJ315 2.5 16 15 2 30 20-0-0 J6 OJ315 2.5 16 4 20-0-0 J1 OJ315 2.5 16 20 18-0-0 B27 OJ315 2.5 16 2 2 4 20-0-0 J21 OJ418 3.5 16 35 26-0-0 J9 OJ418 3.5 16 2 2 4 26-0-0 J2 OJ418 3.5 16 3 24-0-0 J8 OJ418 3.5 16 1 24-0-0 J7 OJ418 3.5 16 6 22-0-0 B30 OJ418 3.5 16 1 24-0-0 I Joist Label Description Width Depth Qty Plies Pcs Length B29 NI-60 2.5 16 1 6-0-0 Blocking Label Description Width Depth Qty Plies Pcs Length BLK1 NI-60 2.5 16 LinFt Varies 29-0-0 LVL/LSL Label Description Width Depth Qty Plies Pcs Length B19 2.0E Rigidlam LVL 1.75 11.875 1 3 3 12-0-0 B5 2.0E Rigidlam LVL 1.75 11.875 1 2 2 10-0-0 B20 2.0E Rigidlam LVL 1.75 14 1 2 2 14-0-0 B23 2.0E Rigidlam LVL 1.75 16 1 2 2 48-0-0 B21 2.0E Rigidlam LVL 1.75 16 1 2 2 12-0-0 Rim Board Label Description Width Depth Qty Plies Pcs Length R1 Nordic Rim Board 1.125 X 16 1.125 16 28 12-0-0 Hanger Label Pcs Description Skew Slope Hg1 5 IUS2.56/16 (Max) Hg2 4 IUS3.56/16 (Max) Beam By Others Label Description Width Depth Qty Plies Pcs Length B22 [STEEL BEAM BY OTHER] 1 16-0-0 B24 [STEEL BEAM BY OTHER] 1 26-0-0 Ground Floor Design Method ASD (USA) Building Code IBC 2012 Floor Loads Live 40 Dead 18 Deflection Joist LL Span L/600 TL Span L/360 LL Cant 2L/480 TL Cant 2L/360 Deflection Flush Girder LL Span L/360 TL Span L/240 LL Cant 2L/360 TL Cant 2L/360 Deflection Dropped Girder LL Span L/360 TL Span L/240 LL Cant 2L/360 TL Cant 2L/240 Deflection Header LL Span L/360 TL Span L/240 LL Cant 2L/360 TL Cant 2L/240 Decking Decking OSB 3/4 APA Rated Sturd-I- Floor Fastener Nailed & Glued Legend WS Web Stiffener -ws In Hanger Label Denotes Web Stiffener PS Point Load Support Load from Above Wall Nordic Rim Board 1.125 X 16 NI-60 16 2.0E Rigidlam LVL 1.75 X 11.875 (Dropped) 2.0E Rigidlam LVL 1.75 X 14 (Dropped) 2.0E Rigidlam LVL 1.75 X 16 3.5 X 16 5.5 X 16 OJ314 2.5 X 16 OJ315 2.5 X 16 OJ418 3.5 X 16 Ground Floor 2 X J103 X J1010 J10 @ 19.2" 24 J21 @ 16"2 X J911 J21 @ 16" 2 X J6 J87 J12 @ 19.2" 7 J12 @ 19.2" 6 J7 @ 19.2" 3 J12 @ 19.2" 2 X J6 10 J1 @ 19.2" 10 J1 @ 19.2" 10 J5 @ 19.2" 3 J2 @ 19.2" 3 X J18 6 J14 @ 19.2" 4 J15 @ 19.2"B28 (1 -ply)B25 (1 -ply)B26 (1 -ply)B23 (2 -ply)B21 (2 -ply) B19 (3 -ply) B5 (2 -ply)B24 (1 -ply)B22 (1 -ply)B27 (2 -ply)B27 (2 -ply)B20 (2 -ply) B29 (1 -ply)B30 (1 -ply)PSPS PSPSPSPSPSPSPSPSPSPS PS R1 R1R1 R1R1 R1R1R1 R1R1 R1R1 R1R1R1 R1R1R1R1R1R1R1 R1 BLK1 (NI-60 -16")BLK1 (NI-60 -16") BLK1 (NI-60 -16") BLK1 (NI-60 -16") 4 X Hg2 Hg1-wsHg1-ws3 X Hg1 DESIGN ASSUMES UNFINISHED AREAS OF THE BASEMENT TO HAVE 1/2" DRYWALL APPLIED TO THE CEILING. STRONGBACK INSTALLED MIDSPAN. SEE DETAIL #5THIS DETAIL ONLY APPLIES TO UNFINISHED AREAS. Reinforcement Table All dimensions and faces are referenced when looking at the joist with the trimmable end on the right. B25-A Add REINFORCEMENT: Plywood 32/16 4Ply (15/32") x 16" of height x 16" of length, starting at 0" from left end, in VERTICAL position, fixed on BOTH sides to top and bottom chord with PL PREMIUM glue and 3" nails at 5" o.c. Add REINFORCEMENT: Plywood 32/16 4Ply (15/32") x 16" of height x 16" of length, starting at 94 7/16" from left end, in VERTICAL position, fixed on ONE side to top and bottom chord with PL PREMIUM glue and 3" nails at 5" o.c. B28-A Add REINFORCEMENT: Plywood 32/16 4Ply (15/32") x 16" of height x 16 7/16" of length, starting at 0" from left end, in VERTICAL position, fixed on BOTH sides to top and bottom chord with PL PREMIUM glue and 3" nails at 5" o.c. Add REINFORCEMENT: Plywood 32/16 4Ply (15/32") x 16" of height x 32" of length, starting at 97 3/16" from left end, in VERTICAL position, fixed on FRONT side over previously installed wood filler parts with PL PREMIUM glue and to top and bottom chord with PL PREMIUM glue and 3" nails at 5" o.c. Add WOOD FILLER: 19/32" of thickness Plywood or OSB x 13" of height x 12 13/16" of length, STARTING at 112 3/8" from LEFT end, fixed on FRONT side to OSB panel with PL PREMIUM glue. Add WOOD FILLER: Plywood 32/16 4Ply (15/32") x 13" of height x 24" of length, STARTING at 101 3/16" from LEFT end, fixed on FRONT side over previously installed wood filler parts, fixed with PL PREMIUM glue and 2" nails at 3" o.c. to webs. B30-A Add REINFORCEMENT: Plywood 32/16 4Ply (15/32") x 16" of height x 16 7/16" of length, starting at 0" from left end, in VERTICAL position, fixed on BOTH sides to top and bottom chord with PL PREMIUM glue and 3" nails at 5" o.c. Add REINFORCEMENT: Plywood 32/16 4Ply (15/32") x 16" of height x 32" of length, starting at 97 3/16" from left end, in VERTICAL position, fixed on BACK side over previously installed wood filler parts with PL PREMIUM glue and to top and bottom chord with PL PREMIUM glue and 3" nails at 5" o.c. Add WOOD FILLER: 2 plies of Plywood 32/16 4Ply (15/32") x 13" of height x 24" of length, STARTING at 101 3/16" from LEFT end, fixed on BACK side to webs with PL PREMIUM glue and 2" nails at 3" o.c. J14-A Add REINFORCEMENT: Plywood 32/16 4Ply (15/32") x 16" of height x 16 7/16" of length, starting at 0" from left end, in VERTICAL position, fixed on BOTH sides to top and bottom chord with PL PREMIUM glue and 3" nails at 5" o.c. J14-B Add REINFORCEMENT: Plywood 32/16 4Ply (15/32") x 16" of height x 16 7/16" of length, starting at 0" from left end, in VERTICAL position, fixed on BOTH sides to top and bottom chord with PL PREMIUM glue and 3" nails at 5" o.c. J15-A Add REINFORCEMENT: Plywood 32/16 4Ply (15/32") x 16" of height x 16 7/16" of length, starting at 0" from left end, in VERTICAL position, fixed on BOTH sides to top and bottom chord with PL PREMIUM glue and 3" nails at 5" o.c. J15-B Add REINFORCEMENT: Plywood 32/16 4Ply (15/32") x 16" of height x 16 7/16" of length, starting at 0" from left end, in VERTICAL position, fixed on BOTH sides to top and bottom chord with PL PREMIUM glue and 3" nails at 5" o.c. J15-C Add REINFORCEMENT: Plywood 32/16 4Ply (15/32") x 16" of height x 16 7/16" of length, starting at 0" from left end, in VERTICAL position, fixed on BOTH sides to top and bottom chord with PL PREMIUM glue and 3" nails at 5" o.c. J18-A Add REINFORCEMENT: Plywood 32/16 4Ply (15/32") x 16" of height x 16 7/16" of length, starting at 0" from left end, in VERTICAL position, fixed on BOTH sides to top and bottom chord with PL PREMIUM glue and 3" nails at 5" o.c. J18-B Add REINFORCEMENT: Plywood 32/16 4Ply (15/32") x 16" of height x 16 7/16" of length, starting at 0" from left end, in VERTICAL position, fixed on BOTH sides to top and bottom chord with PL PREMIUM glue and 3" nails at 5" o.c. J18-C Add REINFORCEMENT: Plywood 32/16 4Ply (15/32") x 16" of height x 16 7/16" of length, starting at 0" from left end, in VERTICAL position, fixed on BOTH sides to top and bottom chord with PL PREMIUM glue and 3" nails at 5" o.c. J2-A Add REINFORCEMENT: Plywood 32/16 4Ply (15/32") x 16" of height x 16 7/16" of length, starting at 0" from left end, in VERTICAL position, fixed on BOTH sides to top and bottom chord with PL PREMIUM glue and 3" nails at 5" o.c. J2-B Add REINFORCEMENT: Plywood 32/16 4Ply (15/32") x 16" of height x 16 7/16" of length, starting at 0" from left end, in VERTICAL position, fixed on BOTH sides to top and bottom chord with PL PREMIUM glue and 3" nails at 5" o.c.Version 21.80.417Powered by iStructDataset: 22022101.1447 This placement plan is to be used as an installation guide only. It is meant to be used in conjunction with the manufacturers installation guide, the architectural and structural drawings, and not to replace them. Layout Name 220532WBIN Description GADDY RES Created December 14, 2022 Revised December 14, 2022 Builder CARTER NOBLESVILLE Dealer Sales Rep TIM Designer Second Floor Floor Truss Label Description Width Depth Qty Plies Pcs Length B18 OJ314 2.5 16 1 2 2 12-0-0 B15 OJ314 2.5 16 1 10-0-0 J5 OJ314 2.5 16 4 16-0-0 J4 OJ314 2.5 16 22 14-0-0 J3 OJ314 2.5 16 17 12-0-0 J12 OJ314 2.5 16 24 10-0-0 J6 OJ315 2.5 16 3 20-0-0 J1 OJ315 2.5 16 2 18-0-0 J21 OJ418 3.5 16 37 26-0-0 J8 OJ418 3.5 16 5 24-0-0 J7 OJ418 3.5 16 6 22-0-0 I Joist Label Description Width Depth Qty Plies Pcs Length B29 NI-60 2.5 16 1 6-0-0 LVL/LSL Label Description Width Depth Qty Plies Pcs Length B1 2.0E Rigidlam LVL 1.75 9.5 1 2 2 36-0-0 B2 2.0E Rigidlam LVL 1.75 9.5 1 3 3 6-0-0 B3 2.0E Rigidlam LVL 1.75 11.875 1 2 2 14-0-0 B4 2.0E Rigidlam LVL 1.75 11.875 2 3 6 10-0-0 B5 2.0E Rigidlam LVL 1.75 11.875 1 2 2 10-0-0 B16 2.0E Rigidlam LVL 1.75 16 1 4 4 24-0-0 B8 2.0E Rigidlam LVL 1.75 16 1 3 3 22-0-0 B10 2.0E Rigidlam LVL 1.75 16 1 2 2 18-0-0 B6 2.0E Rigidlam LVL 1.75 16 1 3 3 14-0-0 B11 2.0E Rigidlam LVL 1.75 16 1 2 2 8-0-0 B9 2.0E Rigidlam LVL 1.75 16 1 2 2 6-0-0 B12 2.0E Rigidlam LVL 1.75 18 1 2 2 34-0-0 B7 2.0E Rigidlam LVL 1.75 18 1 3 3 16-0-0 B13 2.0E Rigidlam LVL 1.75 24 1 3 3 34-0-0 Rim Board Label Description Width Depth Qty Plies Pcs Length R1 Nordic Rim Board 1.125 X 16 1.125 16 24 12-0-0 Hanger Label Pcs Description Skew Slope Hg1 35 IUS2.56/16 (Max) Hg2 2 IUS3.56/16 (Max) Beam By Others Label Description Width Depth Qty Plies Pcs Length B14 [STEEL BEAM BY OTHER] 1 36-0-0 Second Floor Design Method ASD (USA) Building Code IBC 2012 Floor Loads Live 40 Dead 18 Deflection Joist LL Span L/600 TL Span L/360 LL Cant 2L/600 TL Cant 2L/360 Deflection Flush Girder LL Span L/360 TL Span L/240 LL Cant 2L/360 TL Cant 2L/360 Deflection Dropped Girder LL Span L/360 TL Span L/240 LL Cant 2L/360 TL Cant 2L/240 Deflection Header LL Span L/360 TL Span L/240 LL Cant 2L/360 TL Cant 2L/240 Decking Decking OSB 3/4 APA Rated Sturd-I- Floor Fastener Nailed & Glued Legend WS Web Stiffener -ws In Hanger Label Denotes Web Stiffener PS Point Load Support Load from Above Wall Nordic Rim Board 1.125 X 16 NI-60 16 2.0E Rigidlam LVL 1.75 X 9.5 (Dropped) 2.0E Rigidlam LVL 1.75 X 11.875 (Dropped) 2.0E Rigidlam LVL 1.75 X 16 2.0E Rigidlam LVL 1.75 X 16 (Dropped) 2.0E Rigidlam LVL 1.75 X 18 (Dropped) 2.0E Rigidlam LVL 1.75 X 24 (Dropped) 3.5 X 16 OJ314 2.5 X 16 OJ315 2.5 X 16 OJ418 3.5 X 16 Second Floor 1'10 3/16" 1'7 3/16"1'7 3/16"2 X J128 J21 @ 16"J3 2 X J6 6 J3 @ 19.2" 10 J3 @ 19.2" 4 J5 @ 19.2" 22 J4 @ 19.2" 6 J7 @ 19.2" 2 X J12 J65 J8 @ 19.2" 22 J12 @ 19.2" 9 J21 @ 19.2"B15 (1 -ply)B7 (3 -ply)B10 (2 -ply)B11 (2 -ply)B9 (2 -ply)B4 (3 -ply)B4 (3 -ply) B3 (2 -ply) B5 (2 -ply) B2 (3 -ply) B1 (2 -ply) B14 (1 -ply)B18 (2 -ply)B13 (3 -ply)B12 (2 -ply)B8 (3 -ply) B6 (3 -ply)B16 (4 -ply)B29 (1 -ply)R1 R1R1 R1 R1R1R1 R1R1R1 R1R1R1R1R1R1R1R1R1R1R1R1R122 x Hg1 (IUS2.56/16 (Max))Hg1-ws 2 X Hg12 X Hg210 x Hg1 (IUS2.56/16 (Max)) DESIGN ASSUMES UNFINISHED AREAS OF THE BASEMENT TO HAVE 1/2" DRYWALL APPLIED TO THE CEILING. STRONGBACK INSTALLED MIDSPAN. SEE DETAIL #5THIS DETAIL ONLY APPLIES TO UNFINISHED AREAS. Reinforcement Table All dimensions and faces are referenced when looking at the joist with the trimmable end on the right. B15-A Add REINFORCEMENT: Plywood 32/16 4Ply (15/32") x 16" of height x 16" of length, starting at 90 11/16" from left end, in VERTICAL position, fixed on ONE side to top and bottom chord with PL PREMIUM glue and 3" nails at 5" o.c. Version 21.80.417Powered by iStructDataset: 22022101.1447 This placement plan is to be used as an installation guide only. It is meant to be used in conjunction with the manufacturers installation guide, the architectural and structural drawings, and not to replace them.