HomeMy WebLinkAboutSheet A111WALL THICKNESS PRE-FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT METAL STUD EXISTING WINDOW MULLION EQUAL ENTRY 101 OFFICE 109 OFFICE 108 OFFICE 111 OFFICE 110 BREAK + COPY 112 STORAGE 102 WORK ROOM 104 OFFICE 105 4'-0"4'-0"3'-7"9'-7"7'-10" 11'-11"13'-7"9'-5" 135°13'-11"2'-6" 2'-7"CLEARCLEAR 13'-5"11'-10" 2'-4"3'-1"FE 9'-5"14'-6"12'-0"OFFICE 106 ARCHITECTURAL FLOOR PLAN A111 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. PROVIDE PLYWOOD PHONE BOARD, 4'x8'x3 4", PAINTED WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. NEW FIRE EXTINGUISHER AND SEMI-RECESSED CABINET TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. CONFIRM THAT EXISTING WALL MATCHES WALL TYPE "W2". IF NOT, ALTER EXISTING WALL AS REQUIRED TO MATCH "W2". WRAP EXISTING COLUMN WITH DRYWALL AS TIGHTLY AS POSSIBLE. AT WORK ROOM 104, PROVIDE METAL ACCESS PANEL FOR BUILDING ROOF DRAIN. COORDINATE SIZE OF PANEL AND LOCATION WITH PROPERTY MANAGEMENT. _______________________________________________________________ PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. PROVIDE INSULATION ON ALL NEW AND EXISTING PIPING. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. CONTRACTOR TO INSTALL AUTOMATIC SHUTOFF VALVES AND BACK FLOW PREVENTERS AS REQUIRED. PROVIDE WATER LINE WITH BACKFLOW PREVENTER FOR REFRIGERATOR. CONFIRM LOCATION WITH TENANT. PLAN NOTES ARCHITECTURAL PLANAREA NOT IN CONTRACT AREA OF WORK WALL DOOR AND FRAME (SEE DOOR SCHEDULE) NEW CONSTRUCTION EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHTWINDOW / SIDELIGHT ARCHITECTURAL LEGEND PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL DEMISING WALL TO DECK WITH INSULATION 358" METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING W1 WALL WITH INSULATION 358 " METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING W2 WALL TYPES W1 NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. DESCRIPTIONDATE ISSUE 12.16.22 REVIEW SET 02.21.23 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.8888 Keystone Crossing, Suite 100Indianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR ELITE HOME REHABAND HEALTHCARELAKESIDE GREEN BUSINESS CENTER, SUITE 115645 W. CARMEL DRIVE, CARMEL, IN 46032BMEH 2022.242 1ST FLOOR N0 2' 4' 8' 16' 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. 3. PROVIDE INSULATION ON ALL NEW AND EXISTING PLUMBING PIPING AND BACK FLOW PREVENTERS ON ALL WATER LINES AS REQUIRED. GENERAL NOTES NOT TO SCALE WALL AT MULLION DETAIL A111 1 W? TYP. A111 1 A211 8 A211 5,6 A211 3 A211 4 W2 A211 7 A211 2 PARTIAL HEIGHT WALL 358 " METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; SEE ELEVATION FOR WALL HEIGHT; PROVIDE 1" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED; W3 W3 W2 03/08/23