HomeMy WebLinkAboutSheet A121ELNS N SNSNSNS N SNSNSNS N SNDELNELN REFLECTED CEILING PLAN A121 PROVIDE NEW CEILING GRID AND TILE TO MATCH AND ALIGN WITH EXISTING SUCH THAT NEW AND EXISTING CEILINGS APPEAR CONTINUOUS. CONTROL ENTRY 101 AND BREAK + COPY 112 LIGHTING WITH SWITCH AT THIS LOCATION PLAN NOTES LIGHT CIRCUIT LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH ND N N3 D 3 EXIT LIGHT FIXTURE, DUAL LITE LX EVE SERIES; LED LIGHT FIXTURE, PENDANT, LIGHTOLOGY LITHIUM PENDANT #TWO901729 LIGHT FIXTURE, 2'x4', METALUX 24 CZ 4000K RELOCATED DIFFUSER, LAY-IN, 2'x2' ARMSTRONG SILHOUETTE 1 4" REVEAL CEILING GRID, 9 16" SUSPENSION SYSTEM, 2'x2' NIGHT LIGHT NEW OR RELOCATED EXISTING TO REMAIN LIGHT FIXTURE, 6"x8', LED, SURFACE MOUNTED WALL WASH, 8'-0" LENGTH LIGHT FIXTURE, PENDANT EXIT LIGHT FIXTURE LIGHT CIRCUIT LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH CEILING GRID, SUSPENDED, 2'x2' DIFFUSER, LAY-IN, 2'x2' LIGHT FIXTURE, 2'x4' LEGEND REFLECTED CEILING PLANAREA NOT IN CONTRACT AREA OF WORK DESCRIPTIONDATE ISSUE 12.16.22 REVIEW SET 02.21.23 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.8888 Keystone Crossing, Suite 100Indianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR ELITE HOME REHABAND HEALTHCARELAKESIDE GREEN BUSINESS CENTER, SUITE 115645 W. CARMEL DRIVE, CARMEL, IN 46032BMEH 2022.242 1ST FLOOR N0 2' 4' 8' 16' EMERGENCY LIGHT FIXTURE, BUILDING STANDARD EMERGENCY LIGHT FIXTURE MECHANICAL DIFFUSER RELOCATION A121 1 *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION EXISTING VAV BOXES OR HEAT PUMP AND MAIN SUPPLY DUCTS TO REMAIN RELOCATE DIFFUSERS & FLEXDUCT IF REQUIRED VAV / HEAT PUMP A121 1 1. INSTALL NEW CEILING GRID 2X2 AT 8'-6". PROVIDE NEW CEILING TILES THROUGHOUT. 2X2 ARMSTRONG GEORGIAN #1753B TEGULAR BEVELED EDGE LAY IN. 2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. OVER 50% OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 4. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 5. NEW DEVICES AND FACE PLATES TO BE WHITE. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS.  ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 7. LIGHTING VENDOR TO PROVIDE PHOTOMETRIC STUDY TO CONFIRM ALL REQUIRED FIXTURE QUANTITIES PRIOR TO ORDERING. LIGHTING VENDOR TO COORDINATE WITH SCHOTT DESIGN AS REQUIRED TO ENSURE PROPER LIGHTING LEVELS. GENERAL NOTES 1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED.  ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED;  MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. MECHANICAL NOTES 03/08/23