ELECTRICAL PLAN
E111
PROVIDE POWER AS REQUIRED AT DOOR FOR CARD READER
(CARD READER BY TENANT). COORDINATE WITH TENANT'S
SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MORE
DETAILS.
COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE
DEDICATED RECEPTACLE AS REQUIRED.
PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET
INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT
60" AFF.
PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED
TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT
LOCATION WITH TENANT.
PROVIDE FLUSH MOUNT FLOOR CORE FOR MOCKETT GROMMET IN
ISLAND SURFACE; PCS82D - POP UP POWER GROMMET - 2
POWER/USB-C CHARGER IN MATTE WHITE. COORDINATE WITH GC
ON EXACT LOCATION. PROVIDE GROMMETT SUBMITTAL TO
TENANT FOR APPROVAL PRIOR TO ORDERING.
PLAN NOTES
ELECTRICAL PLANAREA NOT IN CONTRACT
AREA OF WORK
LEGEND
DESCRIPTIONDATE
ISSUE
12.16.22 REVIEW SET
02.21.23 PERMIT SET
REVISIONS
DESCRIPTIONMARK DATE DB
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.8888 Keystone Crossing, Suite 100Indianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER
DRAWN BYPROJ. MGR ELITE HOME REHABAND HEALTHCARELAKESIDE GREEN BUSINESS CENTER, SUITE 115645 W. CARMEL DRIVE, CARMEL, IN 46032BMEH
2022.242
1ST FLOOR
N0 2' 4' 8' 16'
1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF
FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL
NEW DEVICES AND FACE PLATES TO BE WHITE.
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI.
4. CONTRACTOR TO PROVIDE GFCI OUTLET FOR WATER HEATER AND
AUTOMATIC SHUTOFF VALVES AS REQUIRED.
5. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
MUST COMPLY WITH ALL APPLICABLE CODES.
6. TVS TO BE PROVIDED BY TENANT AND INSTALLED BY GC.
7. GC TO CONFIRM ALL POWER AND DATA LOCATIONS WITH TENANT
PRIOR TO ROUGH-IN.
GENERAL NOTES
DED
POWER OUTLET, DUPLEX
NEW CONSTRUCTION EXISTING TO REMAIN
POWER OUTLET,
QUADRUPLEX
POWER OUTLET, DUPLEX
POWER OUTLET,
QUADRUPLEX
FLOOR BOX WITH POWER
AND DATA, FLUSH
MOUNTED
FLOOR BOX WITH POWER
AND DATA, FLUSH
MOUNTED
DEDICATED CIRCUIT
DATA/COMMUNICATION
OUTLET (PROVIDE BOX
AND PULL STRING ONLY)
DATA/COMMUNICATION
OUTLET
GFCI GROUND FAULT CIRCUIT
INTERRUPT OUTLET
HEIGHT OF ELECTRICAL
OR DATA DEVICE
+42"