Loading...
HomeMy WebLinkAboutSheet L100ENTRY 101 x OFFICE 109 10'-6"15'-2" x OFFICE 10815'-8"15'-1" x OFFICE11111'-7"13'-7"x OFFICE 110 11'-6"13'-6" BREAK + COPY 112 x STORAGE 102 11'-7"13'-1"x WORK ROOM10413'-3"13'-1"x OFFICE1059'-0"13'-1"ELNFE ELNELN OFFICE 106 285 SF ENTRY 101 x OFFICE 109 10'-6"15'-2" x OFFICE 108 15'-8"15'-1" x OFFICE 111 11'-7"13'-7"x OFFICE 110 11'-6"13'-6" REFRIG BY TENANT BREAK + COPY 112 x STORAGE 102 11'-7"13'-1"x WORK ROOM 104 13'-3"13'-1"x OFFICE 105 9'-0"13'-1" TVELN FE ELNELN TVOFFICE 106 285 SF LIFE SAFETY PLAN L100LIFE SAFETY PLAN DESCRIPTIONDATE ISSUE 12.16.22 REVIEW SET 02.21.23 PERMIT SET REVISIONS DESCRIPTIONMARK DATE DB THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.8888 Keystone Crossing, Suite 100Indianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR ELITE HOME REHABAND HEALTHCARELAKESIDE GREEN BUSINESS CENTER, SUITE 115645 W. CARMEL DRIVE, CARMEL, IN 46032BMEH 2022.242 1ST FLOOR N 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES. 4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. LIFE SAFETY NOTES L1. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. L3. SQUARE FOOTAGES NOTED IN CODE SUMMARY CHART ARE NOT REFLECTIVE OF USABLE/RENTABLE SQUARE FOOTAGE AS CALCULATED BY METHODS SUCH AS BOMA STANDARDS. OCCUPANCY CALCULATIONS & TOTALS ARE CALCULATED BASED ON INTERNATIONAL BUILDING CODE NOT ACTUAL HEAD COUNTS. CONTACT SDI FOR ADDITIONAL INFORMATION AS NECESSARY. GENERAL NOTES 0 8' 16'4' EXISTING ELECTRICAL PANEL LOCATION EXISTING EXIT EP EX LEGEND FIRE EXTINGUISHER EXIT SIGN FE EMERGENCY LIGHT FE AREA NOT IN CONTRACT AREA OF WORK TRAVEL DISTANCE SCOPE OF WORK OFFICE REMODEL OF WHITEBOX OFFICE SPACE TOTAL BUILDING AREA TOTAL PROJECT AREA CHANGE OF OCCUPANCY CLASS? OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD NO OCCUPANCY CLASSIFICATION B(USINESS) GEN. OFFICE SF 100 NUMBER OF EXITS REQUIRED: 2 PROVIDED: 2 SPRINKLER SYSTEM (YES/NO)YES - EXISTING TO REMAIN TOTAL AREA OF ACCESSORY USES 0 TOTAL AREA ON THE FLOOR SF SF/FLOOR X STORIES SF SF 58,182 SF ACCESSORY AREA EXCEEDS 10%NO FIRE BARRIERS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A = TOTAL OCCUPANTS IN PROJECT AREA 25 CODE SUMMARY PREVIOUS USE OF SPACE B(USINESS) ASHRAE 90.1 SUMMARY WILL MEET REQUIREMENTS BUILT BEFORE 1978?NO 2,416 2,416 58,182 1 58,182 25 - LED EDGE LIT BUILDING CONSTRUCTION TYPE II-B TRAVEL DISTANCE = 167' BUSINESSBUSINESS BUSINESS BUSINESS BUSINESS BUSINESS L100 1 ENLARGED PLAN L100 1 EX EX EX EP BUSINESS BUSINESS EX EX EX 03/08/23