Loading...
HomeMy WebLinkAboutLS1 - LIFE SAFETY PLAN355 City Center Drive Carmel, Indiana 46032 317.705.7979 (voice) 317.705.7980 (fax) Architecture / Project Management Supplemental Drawing 840 South Rangeline Road Carmel, IN 46032 LITTLE TULIP TREE LITTLE TULIP TREE LIFE SAFETY & CODE SUMMARY PROJECT SUMMARY This project is a remodeled tenant improvement project known as LITTLE TULIP TREE, occupying 1,768 square feet of the ground floor of an existing Shell and Core project known as the NASH Building (D) of Phase 2 at Carmel City Center. LITTLE TULIP TREE project occupies approximately fifteen percent (15%) of the ground floor area of a three (3) story building. Beneath the ground floor and separated with a 1-hour fire resistive assembly, is an enclosed basement parking level. LITTLE TULIP TREE project is a Group M occupancy, and the construction type of this project and the shell and core is V-A. The entire facility is fully protected by an automatic sprinkler system, and is surrounded by at least 30 feet of yard space on three sides. The LITTLE TULIP TREE tenant is a Mercantile Occupancy offering baby and young kid clothing for the residences of Carmel. APPLICABLE CODES & STANDARDS Indiana General Administrative Rules (675 IAC 12) 2006 Indiana Building Code (IBC 2012) 2014 Accessibility-Indiana Building Code (ANSI A117.1-2009) 2014 Minimum Design Loads for Buildings (ASCE 7-2010) 2014 Indiana Plumbing Code, 2012 Edition (IPC 2006) 2012 Indiana Mechanical Code, 2014 Edition (IMC 2012) 2014 Indiana Electrical Code, 2008 Edition (NFPA 70-2008) 2009 Indiana Fuel Gas Code, 2014 Edition (IFGC 2012) 2014 Indiana Fire Code (IFC 2012) 2014 Indiana Energy Conservation Code (ASHRAE 90.1 2007) 2010 NFPA 10-2010 Portable Fire Extinguishers 2012 NFPA 13-2010 Installation of Fire Sprinkler Systems 2012 NFPA 72-2010 National Fire Alarm Code 2014 NFPA 90A- Installation of Air Conditioning & Ventilating Systems 2015 NFPA 90m — Installation of Warm Air Heating & Air Conditioning Systems 2015 ADA Standards for Accessible Design 2010 OCCUPANCY CLASSIFICATIONS: LITTLE TULIP TREE Tenant: Group M Building Shell & Core: Group R-2; Group A-2 and 3; Group B; Group M Parking Garage: Group S-2 OCCUPANT LOAD LITTLE TULIP TREE Total Gross Area 1,768 sq ft M Occupancy 1,768 sf @ 30 sf/person 59 persons CONSTRUCTION TYPES: LITTLE TULIP TREE Tenant: Type V-A Building Shell & Core: Type V-A Parking Garage: Type V-A BUILDING AREAS: LITTLE TULIP TREE Tenant: 1,768.00 sf Shell & Core: (Ground Floor) 11,701.00 sf Shell & Core: (Total Building D) 17,760.00 sf Shell & Core: (Incl. Garage) 41,636.50 sf Total Building Area 71,087.50 sf FIRE RESISTANCE LITTLE TULIP TREE Tenant & Shell & Core (Ground Floor): Walls: 1 hour Exit Passageways: 1 hour Fire walls: 1 hour Exit Access Corridors: 1 hour Floor: 1 hour (Separating B and S-2) Ceiling: 1 hour (Separating B and R-2) INTERIOR FINISHES LITTLE TULIP TREE Tenant & Shell & Core (Ground Floor): Vertical Exits & Passageways: Class B Exit Access Corridors Class C All Others Class C FIRE PROTECTION 100% protection by an automatic sprinkler system per NFPA 13-2010 100% protection by a fire alarm & annuciator system meeting NFPA 72-2010 ACCESSIBILITY REQUIREMENTS All tenant restrooms comply with ICC/ANSI A117.1-2009; Section 604.5.1 1/6/23 LS1 03/08/23