APPLICABLE CODES:
ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING
BUILDING CODE
2014 INDIANA BUILDING CODE (2012 IBC WITH STATE AMENDMENTS)
STRUCTURAL CODE
2012 INDIANA BUILDING (2012 IBC, ASCE-7-2010)
PLUMBING CODE
2012 INDIANA PLUMBING CODE
MECHANICAL CODE
2014 INDIANA MECHANICAL CODE (2012 IMC WITH STATE AMENDMENTS)
ELECTRICAL CODE
2009 INDIANA ELECTRICAL CODE (2008 NEC WITH AMENDMENTS)
FIRE/LIFE SAFETY CODE
2014 INDIANA FIRE CODE (2012 IFC WITH STATE AMENDMENTS)
ACCESSIBILITY CODE
2014 INDIANA BUILDING CODE, CH11-ACCESSIBILITY, ANSI A-117.1 STANDARD, ADA
ACCESSIBILITY GUIDELINES - 2009 EDITION
ENERGY CODE
2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007) WITH INDIANA
AMMENDMENTS GENERAL ADMINISTRATIVE RULES 2ND EDITION.
CODE SUMMARY
GENERAL NOTES
APPLICABLE WHERE REQUIRED BY CODE:
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED
PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE
REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE.
FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY.
2. IF REQUIRED, PROVIDE ALARM NOTIFICATION APPLIANCES
(HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS,
FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION
SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES
(INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE,
NFPA).
3. IF FIRE PROTECTION EXISTS OR IS REQUIRED, ALL FIRE
PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A
COMPLETE, WORKING SYSTEM. PARALLEL DESIGN GROUP, IS NOT
RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION
OF THE FIRE SPRINKLER SYSTEM.
4. WHERE APPLICABLE, THE FIRE PROTECTION CONTRACTOR SHALL
GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE
DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND
LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT.
5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO
NFPA 10. COORDINATE WITH OWNER/LANDLORD ON
EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE
OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
6. REFER TO WALL TYPES SHEET FOR WALL TYPE AND
CONSTRUCTION DETAILS.
7. PROVIDE NEW EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS,
ALARM NOTIFICATION APPLIANCES AS REQUIRED BY CODE.
APPLICABLE BUILDING CODES
OCCUPANCY LOADS
EXISTING ELECTRICAL PANEL LOCATION
BUILDING EXIT LOCATION
EMERGENCY LIGHTING
NIGHT LIGHT/EMERGENCY LIGHTING;
REFERENCE REFLECTED CEILING PLAN
LEGEND
EX
EL
NL
EP
ASSEMBLY FUNCTION AREA(S)
STORAGE AREA(S)
FE
EXIT SIGN
SURFACE MOUNTED FIRE EXTINGUISHER
AREA NOT IN CONTRACT
AREA OF WORK
COMMON PATH OF EGRESS
EXIT ACCESS TRAVEL DISTANCE
OPEN OFFICE
446
WORKROOM
418
OFFICE
441
OFFICE
439
OFFICE
438
LG. CONFERENCE
402
OFFICE
442
OFFICE
410
OFFICE
409
OFFICE
408
STORAGE
412
OFFICE
422
OFFICE
423
I.T.
424 SALES
433
WELLNESS
419 OFFICE
443
OFFICE
428
RECEPTION
401
OFFICE
429
OFFICE
430
OFFICE
431
OFFICE
432
FOCUS
416FOCUS
406
BOARDROOM
404
MD. CONFERENCE
403
FOCUS
435
OFFICE
445OFFICE
407
COATS
415
PANTRY
413
OFFICE
444
STG.
417
OFFICE
440SOCIAL HUB
405
FOCUS
411
FOCUS
434
FOCUS
437
ELECTRICAL
427
JANITOR
426
IT/STG
425
MEN'S RR
420
WOMEN'S RR
421
SHAFT
414
BALCONY
450
EP
EXEXFEFEFE
FEFEEXIT ACCESS TRAVEL DISTANCE = 220'EXIT ACCESS TRAVEL DISTANCE = 97'COMMON PATH OF EGRESS = 69'
EXIT ACCESS TRAVEL DISTANCE = 130'
EXIT ACCESS TRAVEL DISTANCE = 103'
ELEL EL ELELEL ELELEL
EL
EL ELCOMMON PATH
OF EGRESS = 19'
CHANGE OF OCCUPANCY CLASS:
No
SPRINKLER SYSTEM (YES/NO):
Yes
TOTAL BUILDING SQ FT:
74,265 SF
SCOPE OF WORK:
FIRST GENERATION OFFICE BUILD-OUT
FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS:
No
1/8" = 1'-0"
LIFE SAFETY PLAN1
OCCUPANCY:
(B)USINESS
EXIT TRAVEL DISTANCE (FEET):
300
NUMBER OF REQUIRED EXITS:
2
COMMON TRAVEL PATH OF EGRESS (FEET):
100
USABLE AREA:
14,791 SF
TOTAL AREA ON FLOOR:
16,383 SF
OCC KEY SPACE TYPE OCC CLASSIFICATION AREA SF PER
OCCUPANT
OCCUPANT
LOAD
(B)USINESS IBC Accessory storage areas, mechanical
equipment room 530 SF 300 1.8
(B)USINESS IBC Assembly without fixed seats -
Unconcentrated (tables and chairs)3,088 SF 15 205.9
(B)USINESS IBC Business areas 11,173 SF 100 111.7
Total Project Area / Total Project Occupant Load 14,791 SF 319.4
[ PROJECT NUMBER ][DATE][DRAWN BY][CHECKED BY][ P ][ W ]N
ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399A001
LIFE SAFETY PLAN2022.19210.21.22ASSURED PARTNERS1 E MAIN STREET CARMEL, INDIANA 46032FOURTH FLOORSF/LWBDREVISION SCHEDULENO.DATEDESCRIPTION03/08/23