HomeMy WebLinkAboutA100-WALL-TYPES-Rev.0A2 A3 WALL PARTITION TYPEPLAN VIEWSECTION VIEWSECTION VIEWREMARKS NON- RATED REFER TO SCHEDULE BELOW FOR PARTITION WIDTH NON- RATED A METAL STUD FRAMING @ 16" O.C. MAX. ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW METAL RUNNER ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL ELIMINATOR TRACK LINE OF STRUCTURE UNDERSIDE OF STRUCTURE CEILING GRID STUD WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA NA 3 -3/4" 4 -7/8"3 -5/8" 2 -1/2" STC: NO SOUND WITH SOUND A2S A3SB2 B3 B6 B1 B1S WALL PARTITION TYPE SEE DETAILS FOR FINISHED HEIGHTPLAN VIEWSECTION VIEWSECTION VIEWREMARKS NON- RATED NON- RATED NON- RATED REFER TO SCHEDULE BELOW FOR PARTITION WIDTH NON- RATED B METAL STUD FRAMING @ 16" O.C. MAX. ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW METAL RUNNER ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL METAL RUNNER LINE OF STRUCTURE STUD WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA NA NA NA 2 -7/8" 3 -3/4" 4 -7/8" 7 -1/4"6" 3 -5/8" 2 -1/2" 1 -5/8" STC: NO SOUND WITH SOUND B2S B3S B6S B8 NON- RATED NA9 -1/4"8" B8S UNDERSIDE OF STRUCTURE C2 C3 C6 C1 C1S WALL PARTITION TYPE 4"PLAN VIEWSECTION VIEWSECTION VIEWREMARKS NON- RATED NON- RATED NON- RATED REFER TO SCHEDULE BELOW FOR PARTITION WIDTH NON- RATED C METAL STUD FRAMING @ 16" O.C. MAX. ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, ONE SIDE PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW METAL RUNNER ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL. METAL RUNNER LINE OF STRUCTURE UNDERSIDE OF STRUCTURE LINE OF CEILING STUD WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA NA NA NA 2 -1/4" 3 -1/8" 4 -1/4" 6 -5/8"6" 3 -5/8" 2 -1/2" 1 -5/8" STC: NO SOUND WITH SOUND C2S C3S C6S C8 NON- RATED NA8 -5/8"8" C8S LATERAL BRACING AT 4'-0" O.C. MAX. E2 E3 E6 E1 E1S WALL PARTITION TYPE PLAN VIEWSECTION VIEWSECTION VIEWREMARKS NON- RATED NON- RATED NON- RATED REFER TO SCHEDULE BELOW FOR PARTITION WIDTH NON- RATED E METAL STUD FRAMING @ 16" O.C. MAX. ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, ONE SIDE PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW METAL RUNNER ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL. METAL RUNNER LINE OF STRUCTURE UNDERSIDE OF STRUCTURE LINE OF CEILING STUD WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA NA NA NA 2 -1/4" 3 -1/8" 4 -1/4" 6 -5/8"6" 3 -5/8" 2 -1/2" 1 -5/8" STC: NO SOUND WITH SOUND E2S E3S E6S E8 NON- RATED NA 8 -5/8"8" E8S D2 D3 D6 D1 D1S WALL PARTITION TYPE4"PLAN VIEWSECTION VIEWSECTION VIEWREMARKS NON- RATED NON- RATED NON- RATED REFER TO SCHEDULE BELOW FOR PARTITION WIDTH NON- RATED D METAL STUD FRAMING @ 16" O.C. MAX. ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW METAL RUNNER ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL METAL RUNNER LINE OF STRUCTURE UNDERSIDE OF STRUCTURE LINE OF CEILING STUD WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA NA NA NA 2 -7/8" 3 -3/4" 4 -7/8" 7 -1/4"6" 3 -5/8" 2 -1/2" 1 -5/8" STC: NO SOUND WITH SOUND D2S D3S D6S D8 NON- RATED NA9 -1/4"8" D8S LATERAL BRACING AT 4'-0" O.C. MAX. F2 F3 F6 F1 F1S WALL PARTITION TYPE PLAN VIEWSECTION VIEWSECTION VIEWREMARKS REFER TO SCHEDULE BELOW FOR PARTITION WIDTH NON- RATED F METAL STUD FRAMING @ 16" O.C. MAX. ONE LAYER 5/8" (TYPE-X) GYPSUM WALL BOARD, EACH SIDE PROVIDE SOUND ATTENUATION INSULATION AS REQUIRED -SEE SCHEDULE BELOW METAL RUNNER ADDITIONAL WALL FINISH (SHOWN DASHED) ON ONE OR BOTH SIDES WHERE OCCURS; REFER TO FLOOR PLANS AND ROOM FINISH SCHEDULE FOR OCCURRENCE, LOCATION, AND EXTENT OF WALL COVERAGE. 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD REPLACES TYPE-X AS SUBSTRATE IN ALL RESTROOMS AND JANITOR'S CLOSETS,TYPICAL METAL RUNNER LINE OF STRUCTURE UNDERSIDE OF STRUCTURE LINE OF CEILING STUD WIDTH PART. WIDTH FIRE RATING UL LISTING WITH SOUND ATTENUATION DESIGNATION NO SOUND ATTENUATION DESIGNATION NA 2 -7/8" 3 -3/4" 4 -7/8" 7 -1/4"6" 3 -5/8" 2 -1/2" 1 -5/8" STC: NO SOUND WITH SOUND F2S F3S F6S F8 9 -1/4"8" F8S NON- RATED NA NON- RATED NA NON- RATED NA NON- RATED NA WALL TYPES ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. NOT ALL WALL TYPES LISTED ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.[ PROJECT NUMBER ][DATE][DRAWN BY][CHECKED BY][ P ][ W ]N ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN.8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399A100 WALL TYPES2022.19210.21.22ASSURED PARTNERS1 E MAIN STREET CARMEL, INDIANA 46032FOURTH FLOORSF/LWBDREVISION SCHEDULENO.DATEDESCRIPTION03/08/23