Loading...
HomeMy WebLinkAboutA201-REFLECTED-CEILING-PLAN-Rev.0DN DN UP DD4 DDDDD333333 44DLEGEND NIGHT LIGHT LOCATION EXIT LIGHT FIXTURE EMERGENCY LIGHT FIXTURE LIGHT SWITCH LIGHT SWITCH, 3-WAY LIGHT CIRCUIT 3 EL 1. PROVIDE NEW CEILING GRID AND TILE (ACT) THROUGHOUT UNLESS NOTED OTHERWISE ON PLAN. CEILING GRID TO BE INSTALLED AS HIGH AS POSSIBLE AT CONSISTENT HEIGHT THROUGHOUT SPACE. 2. ALL SWITCHES AND FACEPLATES TO BE WHITE. 3. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE COVERPLATE. 4. CAN LIGHT FIXTURES TO BE SWITCHED SEPARATELY AND HAVE DIMMERS. 5. CONFIRM ALL DECORATIVE LIGHT LOCATIONS AND HEIGHTS WITH DESIGNER AND PROVIDE NEW ELECTRICAL AS REQUIRED. DO NOT CUT CORD OF PENDANT UNTIL EXACT HEIGHT IS FINALIZED. 6. DECORATIVE FIXTURE(S) SPECIFIED ARE TO BE PURCHASED THRU LOCAL COMMERCIAL VENDOR TO INSURE COMMERCIAL WARRANTIES. PURCHASING FROM OTHER VENDORS OR AVENUES IS AT THE SUPPLIER'S / EC'S RISK NOT, THE PARALLEL DESIGN GROUP'S, OWNER'S, OR TENANT'S. 7. WHERE APPLICABLE, ALL SPRINKLERS IN DRYWALL CEILINGS/BULKHEADS ARE TO HAVE WHITE CONCEALED HEADS. 8. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 9. LIGHTING PLACEMENT AND QUANTITIES ARE FOR REFERENCE ONLY AND ARE TO BE PROVIDED BY LIGHTING CONSULTANT AND ELECTRICIAN. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT LAY- OUT AND TOTAL WATTAGE MEETS ASHRAE 90.1 STANDARDS AND LIGHT LEVELS ARE APPROPRIATE FOR THE USE OF EACH SPACE. OVER 50% OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 10. UNLESS NOTED OTHERWISE ALL NEW SWITCHES MUST BE AN OCCUPANCY SENSOR COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 11. PROVIDE RELAY SYSTEM FOR ALL OF OPEN OFFICE AREA GENERAL LIGHTING. CONFIRM EXACT SPECS WITH DESIGNER. PROVIDE CONTROL PAD LOCATIONS AT EACH STAIR. CONFIRM EXACT LOCATIONS WITH OWNER. GENERAL NOTES MECHANICAL NOTES KEYED NOTES 1. SEE MECHANICAL DRAWINGS PROVIDED BY OTHERS FOR ALL MECHANICAL INFORMATION. 2. LOCATE THERMOSTATS WHERE APPROPRIATE PER MECHANICAL DESIGN. ALL THERMOSTATS TO HAVE LED DISPLAY WITH LOCKOUT CAPABILITY AND LOCK BOX. VERIFY LOCATIONS WITH TENANT BEFORE INSTALLING. 3. WHERE EXPOSED DECK IS SHOWN, VERIFY WITH DESIGNER AND TENANT IF DUCT WORK SHOULD BE SPIRAL DUCT. 2'x4', LED MFG: STYLE: NOTE: SEE LUMEN PACKAGE INFORMATION AND FIXTURE LOCATIONS ON SHEET A202 2'x2', LED MFG: STYLE: NOTE: SEE LUMEN PACKAGE INFORMATION AND FIXTURE LOCATIONS ON SHEET A202 LED RECESSED WALL WASH MFG: LUMENWERX STYLE: LUMENWERX RECESSED FINISH: WHITE X = LENGTH SPECIFIED WW(X) CYLINDER, LED MFG: CONTECH LIGHTING STYLE: 3 1/2" CYLINDERS, 3500K FINISH: WHITE MOUNTING HEIGHT: 9"-6" A.F.F. RECESSED LIGHT FIXTURE, LED MFG: HALO LIGHTING STYLE: 4" SQUARE DOWNLIGHT FINISH: WHITE PENDANT, LED MFG: TECH LIGHTING STYLE: BLOK LARGE PENDANT FINISH: AGED BRASS MOUNTING HEIGHT: 6"-10" A.F.F. PENDANT, LED MFG: HUBBARDTON FORGE STYLE: LINK 10-LIGHT CLEAR GLASS RECTANGULAR PENDANT FINISH: MODERN BRASS -86 MOUNTING HEIGHT: TBD BY DESIGNER ON SITE P1 P2 P3 P4 C1 CYL NL CEILING TYPE CEILING HEIGHT GYP-GYPSUM BOARD CEILING PAINTED (PT1)UNLESS NOTED OTHERWISE ON FINISH PLAN. PROVIDE ALL ACCESS PANELS REQUIRED FOR MAINTENANCE; LOCATIONS SHALL BE APPROVED BY PARALLEL DESIGN GROUP. PROVIDE GYPSUM BOARD VERTICAL SURFACES FOR ALL BULKHEAD CONDITIONS. ACT -2' x 2' ACOUSTICAL CEILING MFG: ARMSTRONG TYPE: DUNE EDGE TYPE: TEGULAR GRID: 15/16" NRC RATING: 0.55 FIRE RATING: CLASS A TRIM: ARMSTRONG AXIOM EDGE, 6" (WHERE REQUIRED) DECK-EXPOSED DECK PAINT (PT2) UNLESS NOTED OTHERWISE ON FINISH PLAN, DRY FALL PAINT. PAINT 10' BEYOND PERIMETER OF CEILINGS WHERE OPEN DECK IS EXPOSED BEYOND AND WHERE IT TRANSITIONS FROM OPEN DECK TO ACOUSTICAL TILE SL1 -FRASCH STRATAWOOD (22MM)-MEDIUM WALNUT ACOUSTIC PANEL WITH LINEAR WOOD SLATS NEW CEILING GRID, SUSPENDED, 2'x2' NEW GYPSUM BOARD CEILING X X' -X"EXPOSED DECK AREA NOT IN CONTRACT AREA OF WORK PENDANT, LED MFG: TECH LIGHTING STYLE: JONI PENDANT FINISH: AGED BRASS MOUNTING HEIGHT: 6"- 0" A.F.F. PENDANT, LED MFG: HUBBARDTON FORGE STYLE: YORK LED PENDANT FINISH: ANTIQUE BRASS -27, LEATHER BLACK, SIZE: 64.10" MOUNTING HEIGHT: 7"- 0" A.F.F. CENTERED OVER ISLAND SM1 SURFACE MOUNT, LED MFG: SHADES OF LIGHT STYLE: STRATO CEILING LIGHT SKU: FM22031 AB FINISH: AGED BRASS LED RECESSED LINEAR, 3500K MFG: LUMENWERX STYLE: VIA 2 (VIA2R) LENS: 0.5" DROP FINISH: MATTE WHITE X = LENGTH SPECIFIED RL.5(X) RECESSED LIGHT FIXTURE, LED MFG: HALO LIGHTING STYLE: 4" SQUARE DOWNLIGHT FINISH: BLACK C2 LED RECESSED LINEAR, 3500K MFG: LUMINII STYLE:BOSCA STATIC WHITE LINEAR ILLUMINATION SYSTEM FINISH: MATTE BLACK X = LENGTH SPECIFIED LL(X) P5 PENDANT, LED MFG: HINKLEY LIGHTING STYLE: LUCA CONVERTIBLE DRUM PENDANT FINISH: BLACK SIZE: 38" MOUNTING HEIGHT: 7'-6" A.F.F. LED RECESSED LINEAR, 3500K MFG: LUMENWERX STYLE: VIA 2 (VIA2R) LENS: 1" DROP FINISH: MATTE WHITE X = LENGTH SPECIFIED RL1(X) LED RECESSED LINEAR, 3500K MFG: LUMENWERX STYLE: VIA 2 (VIA2R) FINISH: MATTE WHITE X = LENGTH SPECIFIED RL(X) LED RECESSED LINEAR PARALETER (DEEP RECESS), 3500K MFG: LUMENWERX STYLE: VIA 2 (VIA2R) FINISH: MATTE WHITE X = LENGTH SPECIFIED LRP(X) LED TRANISIONAL WALL WASH MFG: LUMENWERX TRANSITIONAL SYSTEM STYLE: LUMENWERX RECESSED FINISH: WHITE X = LENGTH SPECIFIED TWW(X) RECESSED LIGHT FIXTURE, LED MFG: HALO LIGHTING STYLE: 2" SQUARE DOWNLIGHT FINISH: WHITE C3 CYLINDER, LED MFG: CONTECH LIGHTING STYLE: 3 1/2" CYLINDERS, 3500K ROD MOUTNING FINISH: WHITE MOUNTING HEIGHT: 9"-6" A.F.F. CYR TL TAPE LIGHT MFG: BEULUX STYLE: TBD (MATERIAL ALLOWANCE OF T02-PDG TAPELIGHT OR EQUAL), 3500K SIZE: VARIES, REFERENCE ELEVATIONS ELEL EL ELELEL ELELEL EL EL EL1 1 11 1 2 2 2EXIST DECK 33 4 3 P2 GYP 9' -3" P2 EQ. EQ. C1C1 C1 C1 P3 P3 P3 EQ. 4' - 6" 4' - 6" EQ.EQ. EQ.P3 SM1 SM1 3 P3 5 GYP 9' -6" GYP 9' -6" C1 C1 C1 C1 C1 C1 GYP 10' - 0" 5 5 GYP 9' -6" GYP 9' -6" 6 7 GYP 9' -6" 8 EQ.6' - 0"EQ.9 9 GYP 9' -3" 6 6 GYP 10' - 0" GYP 10' - 0" GYP 10' - 0" 6 GYP 9' -6" GYP 9' -6"C1C1C1 C1C1 C1 10 CYR CYR CYR CYR CYR CYR CYR CYR CYR CYR CYR CYR CYR CYR CYR CYR EXIST DECK CYL CYL CYL CYL CYL CYL CYL C1 C1 C1 LL (8) THIS TRANSITION MIGHT NOT BE RIGHT DEPENDING ON CEILING GRID/TILE HEIGHT 11 11 GYP 9' -3"3' - 11 1/2" 8' - 3"8' - 7"LL (4) LL (4) LL (4) LL (12) LL (8) LL (4) C2 C2 C2 C2C2C2 C2 C2 C2 P1 P1 P1 P5 1 CYL CYL CYL 2' - 6" TWW(10)121' - 11 3/8"RL(12)C3 LR.5(8) LR.5(8) LR.5(8)LR1(4) LR1(4) LR1(4) LR1(4) LR1(4) LR1(4) LR(6) LR(6)LR(6) 12 C1 C1 C1 C1 CYR CYR CYR CYR LRP(10)RL(4)RL(4) TL 1 SEE BUILDING CORE AND SHELL DRAWINGS PROVIDED BY OTHERS FOR INFORMATION ON CEILING, LIGHTING AND SWITCHES IN THIS ROOM. 2 CONTROL OPEN OFFICE AND HALL LIGHTING WITH 4-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. MAXIMUM OF 2,500 SQUARE FEET PER SWITCH PER ASHRAE 90.1. 3 PROVIDE NEW 6" WIDE DRYWALL BULKHEAD, ALIGNING WITH ADJACENT WALLS AS SHOWN. UNDERSIDE OF BULKHEAD TO EXTEND DOWN 1" BELOW CEILING GRID (ACT) AND EXTEND UP TO DECK. ENTIRE BULKHEAD TO BE PAINTED (PT2). 4 PROVIDE DRYWALL BULKHEAD AS SHOWN. PAINT ALL EXPOSED FACES AND EDGES OF BULKHEAD (PT3). SLAT FINISH (SL1) TO BE APPLIED TO UNDERSIDE OF BULKHEAD AND CONTINUE DOWN TO FLOOR AS NOTED ON FINISH PLAN. 5 PROVIDE DRYWALL BULKHEAD FROM TOP OF UPPER CABINETS TO DECK. INTENT IS FOR VERTICAL FACE OF BULKHEAD TO ALIGN WITH ADJCENT WALL FACES AS SHOWN. ENTIRE BULKHEAD TO BE PAINTED (PT2). 6 VERTICAL FACE OF DRYWALL CEILING TO EXTEND TO DECK ALONG THIS EDGE. INTENT IS FOR VERTICAL FACE OF DRYWALL TO ALIGN WITH ADJACENT WALL FACES. ENTIRE BULKHEAD TO BE PAINTED (PT2). 7 PROVIDE ALL REQUIRED ABOVE CEILING SUPPORT AND CONCEALED TRACKS/HARDWARE FOR NEW MOBILE PARTIION. CONFIRM EXACT REQUIREMENTS AND LOCATION WITH TENANT'S MOBILE PARTITION VENDOR. 8 COORDINATE RECESSED DRYWALL POCKET DEPTH AND WIDTH WITH LIGHTING VENDOR. INTENT IS FOR LINEAR LIGHT FIXTURE TO BE CONCEALED IN RECESSED DRYWALL POCKET. DRYWALL TO BE PAINTED (PT2). 9 INTENT IS FOR VERTICAL FACE OF BULKHEAD TO ALIGN WITH FACE OF WALL AS SHOWN. 10 PROVIDE 6" HIGH ANGLED DRYWALL CEILING AS SHOWN. INTENT IS FOR ANGLE OF CEILING TO FOLLOW FLOORING TRANSITION BELOW. 11 PAINT DRYWALL CEILING (PT3). ALL SWITCH PLATE COVERS IN THIS ROOM TO BE BLACK. 12 PROVIDE NEW 6" WIDE DRYWALL BULKHEAD, ALIGNING WITH ADJACENT WALLS AS SHOWN. UNDERSIDE OF BULKHEAD TO EXTEND DOWN 1" BELOW CEILING GRID (ACT). ENTIRE BULKHEAD TO BE PAINTED (PT2). 1/8" = 1'-0" REFLECTED CEILING PLAN1 [ PROJECT NUMBER ][DATE][DRAWN BY][CHECKED BY][ P ][ W ]N ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THESE DRAWINGS ARE OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT OF PARALLEL DESIGN GROUP INC. CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC. MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS FROM THE DIMENSIONS SHOWN ON THE PLAN.8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399A201 REFLECTED CEILING PLAN2022.19210.21.22ASSURED PARTNERS1 E MAIN STREET CARMEL, INDIANA 46032FOURTH FLOORSF/LWBDREVISION SCHEDULENO.DATEDESCRIPTION1Date 1Revision 103/08/23