DN
UP
DD4
DDDDD333333
44DLEGEND
NIGHT LIGHT LOCATION
EXIT LIGHT FIXTURE
EMERGENCY LIGHT
FIXTURE
LIGHT SWITCH
LIGHT SWITCH, 3-WAY
LIGHT CIRCUIT
3
EL
1. PROVIDE NEW CEILING GRID AND TILE (ACT) THROUGHOUT UNLESS
NOTED OTHERWISE ON PLAN. CEILING GRID TO BE INSTALLED AS HIGH
AS POSSIBLE AT CONSISTENT HEIGHT THROUGHOUT SPACE.
2. ALL SWITCHES AND FACEPLATES TO BE WHITE.
3. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH
A SINGLE COVERPLATE.
4. CAN LIGHT FIXTURES TO BE SWITCHED SEPARATELY AND HAVE
DIMMERS.
5. CONFIRM ALL DECORATIVE LIGHT LOCATIONS AND HEIGHTS WITH
DESIGNER AND PROVIDE NEW ELECTRICAL AS REQUIRED. DO NOT CUT
CORD OF PENDANT UNTIL EXACT HEIGHT IS FINALIZED.
6. DECORATIVE FIXTURE(S) SPECIFIED ARE TO BE PURCHASED THRU
LOCAL COMMERCIAL VENDOR TO INSURE COMMERCIAL WARRANTIES.
PURCHASING FROM OTHER VENDORS OR AVENUES IS AT THE
SUPPLIER'S / EC'S RISK NOT, THE PARALLEL DESIGN GROUP'S, OWNER'S,
OR TENANT'S.
7. WHERE APPLICABLE, ALL SPRINKLERS IN DRYWALL
CEILINGS/BULKHEADS ARE TO HAVE WHITE CONCEALED HEADS.
8. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED
TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE
CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR
REFERENCE ONLY.
9. LIGHTING PLACEMENT AND QUANTITIES ARE FOR REFERENCE ONLY AND
ARE TO BE PROVIDED BY LIGHTING CONSULTANT AND ELECTRICIAN.
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT LAY-
OUT AND TOTAL WATTAGE MEETS ASHRAE 90.1 STANDARDS AND LIGHT
LEVELS ARE APPROPRIATE FOR THE USE OF EACH SPACE. OVER 50% OF
THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE
REQUIREMENTS WILL NEED TO BE MET.
10. UNLESS NOTED OTHERWISE ALL NEW SWITCHES MUST BE AN
OCCUPANCY SENSOR COMBO UNIT WITH BOTH ULTRASONIC AND
INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY
SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY
PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING
MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED.
11. PROVIDE RELAY SYSTEM FOR ALL OF OPEN OFFICE AREA GENERAL
LIGHTING. CONFIRM EXACT SPECS WITH DESIGNER. PROVIDE
CONTROL PAD LOCATIONS AT EACH STAIR. CONFIRM EXACT
LOCATIONS WITH OWNER.
GENERAL NOTES
MECHANICAL NOTES
KEYED NOTES
1. SEE MECHANICAL DRAWINGS PROVIDED BY OTHERS FOR ALL
MECHANICAL INFORMATION.
2. LOCATE THERMOSTATS WHERE APPROPRIATE PER MECHANICAL
DESIGN. ALL THERMOSTATS TO HAVE LED DISPLAY WITH LOCKOUT
CAPABILITY AND LOCK BOX. VERIFY LOCATIONS WITH TENANT
BEFORE INSTALLING.
3. WHERE EXPOSED DECK IS SHOWN, VERIFY WITH DESIGNER AND
TENANT IF DUCT WORK SHOULD BE SPIRAL DUCT.
2'x4', LED
MFG:
STYLE:
NOTE: SEE LUMEN PACKAGE INFORMATION
AND FIXTURE LOCATIONS ON SHEET A202
2'x2', LED
MFG:
STYLE:
NOTE: SEE LUMEN PACKAGE INFORMATION
AND FIXTURE LOCATIONS ON SHEET A202
LED RECESSED WALL WASH
MFG: LUMENWERX
STYLE: LUMENWERX RECESSED
FINISH: WHITE
X = LENGTH SPECIFIED
WW(X)
CYLINDER, LED
MFG: CONTECH LIGHTING
STYLE: 3 1/2" CYLINDERS, 3500K
FINISH: WHITE
MOUNTING HEIGHT: 9"-6" A.F.F.
RECESSED LIGHT FIXTURE, LED
MFG: HALO LIGHTING
STYLE: 4" SQUARE DOWNLIGHT
FINISH: WHITE
PENDANT, LED
MFG: TECH LIGHTING
STYLE: BLOK LARGE PENDANT
FINISH: AGED BRASS
MOUNTING HEIGHT: 6"-10" A.F.F.
PENDANT, LED
MFG: HUBBARDTON FORGE
STYLE: LINK 10-LIGHT CLEAR GLASS
RECTANGULAR PENDANT
FINISH: MODERN BRASS -86
MOUNTING HEIGHT: TBD BY DESIGNER ON SITE
P1
P2
P3
P4
C1
CYL
NL
CEILING TYPE
CEILING HEIGHT
GYP-GYPSUM BOARD CEILING
PAINTED (PT1)UNLESS NOTED OTHERWISE ON FINISH PLAN. PROVIDE ALL ACCESS PANELS REQUIRED
FOR MAINTENANCE; LOCATIONS SHALL BE APPROVED BY PARALLEL DESIGN GROUP. PROVIDE
GYPSUM BOARD VERTICAL SURFACES FOR ALL BULKHEAD CONDITIONS.
ACT -2' x 2' ACOUSTICAL CEILING
MFG: ARMSTRONG
TYPE: DUNE
EDGE TYPE: TEGULAR
GRID: 15/16"
NRC RATING: 0.55
FIRE RATING: CLASS A
TRIM: ARMSTRONG AXIOM EDGE, 6" (WHERE REQUIRED)
DECK-EXPOSED DECK
PAINT (PT2) UNLESS NOTED OTHERWISE ON FINISH PLAN, DRY FALL PAINT.
PAINT 10' BEYOND PERIMETER OF CEILINGS WHERE OPEN DECK IS EXPOSED BEYOND AND WHERE IT
TRANSITIONS FROM OPEN DECK TO ACOUSTICAL TILE
SL1 -FRASCH STRATAWOOD (22MM)-MEDIUM WALNUT
ACOUSTIC PANEL WITH LINEAR WOOD SLATS
NEW CEILING GRID,
SUSPENDED, 2'x2'
NEW GYPSUM BOARD
CEILING
X
X' -X"EXPOSED DECK
AREA NOT IN CONTRACT
AREA OF WORK
PENDANT, LED
MFG: TECH LIGHTING
STYLE: JONI PENDANT
FINISH: AGED BRASS
MOUNTING HEIGHT: 6"- 0" A.F.F.
PENDANT, LED
MFG: HUBBARDTON FORGE
STYLE: YORK LED PENDANT
FINISH: ANTIQUE BRASS -27,
LEATHER BLACK,
SIZE: 64.10"
MOUNTING HEIGHT: 7"- 0" A.F.F.
CENTERED OVER ISLAND
SM1
SURFACE MOUNT, LED
MFG: SHADES OF LIGHT
STYLE: STRATO CEILING LIGHT
SKU: FM22031 AB
FINISH: AGED BRASS
LED RECESSED LINEAR, 3500K
MFG: LUMENWERX
STYLE: VIA 2 (VIA2R)
LENS: 0.5" DROP
FINISH: MATTE WHITE
X = LENGTH SPECIFIED
RL.5(X)
RECESSED LIGHT FIXTURE, LED
MFG: HALO LIGHTING
STYLE: 4" SQUARE DOWNLIGHT
FINISH: BLACK
C2
LED RECESSED LINEAR, 3500K
MFG: LUMINII
STYLE:BOSCA STATIC WHITE
LINEAR ILLUMINATION SYSTEM
FINISH: MATTE BLACK
X = LENGTH SPECIFIED
LL(X)
P5
PENDANT, LED
MFG: HINKLEY LIGHTING
STYLE: LUCA CONVERTIBLE DRUM PENDANT
FINISH: BLACK
SIZE: 38"
MOUNTING HEIGHT: 7'-6" A.F.F.
LED RECESSED LINEAR, 3500K
MFG: LUMENWERX
STYLE: VIA 2 (VIA2R)
LENS: 1" DROP
FINISH: MATTE WHITE
X = LENGTH SPECIFIED
RL1(X)
LED RECESSED LINEAR, 3500K
MFG: LUMENWERX
STYLE: VIA 2 (VIA2R)
FINISH: MATTE WHITE
X = LENGTH SPECIFIED
RL(X)
LED RECESSED LINEAR PARALETER
(DEEP RECESS), 3500K
MFG: LUMENWERX
STYLE: VIA 2 (VIA2R)
FINISH: MATTE WHITE
X = LENGTH SPECIFIED
LRP(X)
LED TRANISIONAL WALL WASH
MFG: LUMENWERX TRANSITIONAL SYSTEM
STYLE: LUMENWERX RECESSED
FINISH: WHITE
X = LENGTH SPECIFIED
TWW(X)
RECESSED LIGHT FIXTURE, LED
MFG: HALO LIGHTING
STYLE: 2" SQUARE DOWNLIGHT
FINISH: WHITE
C3
CYLINDER, LED
MFG: CONTECH LIGHTING
STYLE: 3 1/2" CYLINDERS, 3500K
ROD MOUTNING
FINISH: WHITE
MOUNTING HEIGHT: 9"-6" A.F.F.
CYR
TL TAPE LIGHT
MFG: BEULUX
STYLE: TBD (MATERIAL ALLOWANCE
OF T02-PDG TAPELIGHT OR EQUAL),
3500K
SIZE: VARIES, REFERENCE
ELEVATIONS
ELEL EL ELELEL ELELEL
EL
EL EL1
1
11
1
2
2
2EXIST
DECK
33
4
3
P2
GYP
9' -3"
P2
EQ. EQ.
C1C1 C1 C1
P3
P3 P3
EQ. 4' - 6" 4' - 6" EQ.EQ. EQ.P3
SM1
SM1
3
P3
5
GYP
9' -6"
GYP
9' -6"
C1 C1 C1
C1 C1 C1
GYP
10' - 0"
5
5
GYP
9' -6"
GYP
9' -6"
6
7
GYP
9' -6"
8
EQ.6' - 0"EQ.9 9
GYP
9' -3"
6 6 GYP
10' - 0"
GYP
10' - 0"
GYP
10' - 0"
6
GYP
9' -6"
GYP
9' -6"C1C1C1
C1C1 C1
10
CYR CYR CYR CYR
CYR CYR CYR
CYR CYR CYR
CYR
CYR
CYR
CYR CYR CYR
EXIST
DECK
CYL CYL CYL
CYL CYL CYL
CYL
C1
C1 C1
LL (8)
THIS
TRANSITION
MIGHT NOT BE
RIGHT
DEPENDING ON
CEILING
GRID/TILE
HEIGHT
11
11
GYP
9' -3"3' - 11 1/2" 8' - 3"8' - 7"LL (4)
LL (4) LL (4)
LL (12)
LL (8)
LL (4)
C2 C2 C2
C2C2C2
C2
C2
C2
P1
P1
P1
P5
1 CYL
CYL CYL
2' - 6" TWW(10)121' - 11 3/8"RL(12)C3
LR.5(8)
LR.5(8)
LR.5(8)LR1(4)
LR1(4)
LR1(4)
LR1(4)
LR1(4)
LR1(4)
LR(6) LR(6)LR(6)
12
C1
C1
C1
C1
CYR CYR CYR CYR
LRP(10)RL(4)RL(4)
TL
1 SEE BUILDING CORE AND SHELL DRAWINGS PROVIDED BY
OTHERS FOR INFORMATION ON CEILING, LIGHTING AND
SWITCHES IN THIS ROOM.
2 CONTROL OPEN OFFICE AND HALL LIGHTING WITH 4-WAY
SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS
REQUIRED. MAXIMUM OF 2,500 SQUARE FEET PER SWITCH PER
ASHRAE 90.1.
3 PROVIDE NEW 6" WIDE DRYWALL BULKHEAD, ALIGNING WITH
ADJACENT WALLS AS SHOWN. UNDERSIDE OF BULKHEAD TO
EXTEND DOWN 1" BELOW CEILING GRID (ACT) AND EXTEND UP
TO DECK. ENTIRE BULKHEAD TO BE PAINTED (PT2).
4 PROVIDE DRYWALL BULKHEAD AS SHOWN. PAINT ALL EXPOSED
FACES AND EDGES OF BULKHEAD (PT3). SLAT FINISH (SL1) TO BE
APPLIED TO UNDERSIDE OF BULKHEAD AND CONTINUE DOWN
TO FLOOR AS NOTED ON FINISH PLAN.
5 PROVIDE DRYWALL BULKHEAD FROM TOP OF UPPER CABINETS
TO DECK. INTENT IS FOR VERTICAL FACE OF BULKHEAD TO
ALIGN WITH ADJCENT WALL FACES AS SHOWN. ENTIRE
BULKHEAD TO BE PAINTED (PT2).
6 VERTICAL FACE OF DRYWALL CEILING TO EXTEND TO DECK
ALONG THIS EDGE. INTENT IS FOR VERTICAL FACE OF DRYWALL
TO ALIGN WITH ADJACENT WALL FACES. ENTIRE BULKHEAD TO
BE PAINTED (PT2).
7 PROVIDE ALL REQUIRED ABOVE CEILING SUPPORT AND
CONCEALED TRACKS/HARDWARE FOR NEW MOBILE PARTIION.
CONFIRM EXACT REQUIREMENTS AND LOCATION WITH
TENANT'S MOBILE PARTITION VENDOR.
8 COORDINATE RECESSED DRYWALL POCKET DEPTH AND WIDTH
WITH LIGHTING VENDOR. INTENT IS FOR LINEAR LIGHT FIXTURE
TO BE CONCEALED IN RECESSED DRYWALL POCKET. DRYWALL
TO BE PAINTED (PT2).
9 INTENT IS FOR VERTICAL FACE OF BULKHEAD TO ALIGN WITH
FACE OF WALL AS SHOWN.
10 PROVIDE 6" HIGH ANGLED DRYWALL CEILING AS SHOWN.
INTENT IS FOR ANGLE OF CEILING TO FOLLOW FLOORING
TRANSITION BELOW.
11 PAINT DRYWALL CEILING (PT3). ALL SWITCH PLATE COVERS IN
THIS ROOM TO BE BLACK.
12 PROVIDE NEW 6" WIDE DRYWALL BULKHEAD, ALIGNING WITH
ADJACENT WALLS AS SHOWN. UNDERSIDE OF BULKHEAD TO
EXTEND DOWN 1" BELOW CEILING GRID (ACT). ENTIRE
BULKHEAD TO BE PAINTED (PT2).
1/8" = 1'-0"
REFLECTED CEILING PLAN1 [ PROJECT NUMBER ][DATE][DRAWN BY][CHECKED BY][ P ][ W ]N
ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399A201
REFLECTED
CEILING PLAN2022.19210.21.22ASSURED PARTNERS1 E MAIN STREET CARMEL, INDIANA 46032FOURTH FLOORSF/LWBDREVISION SCHEDULENO.DATEDESCRIPTION1Date 1Revision 103/08/23