HomeMy WebLinkAboutA301-POWER-AND-DATA-PLAN-Rev.0J
DN
DN
UP
TV1TV1DED
DED+44+44 +44+44+44 +44
GFI
+42 TV1+44+44+42DED+42GFI+42GFIJ J J J J
J
JJ J J J J J
+42TV1TV1TV1DED+42 +42RSPGFITV1
TV1
TV1+34+34+34+34TV1TV1TV1TV1TV1TV1TV11. ALL OUTLETS, DEVICES, AND FACEPLATES TO BE WHITE.
2. AT EACH PHONE/DATA JACK, PROVIDE PULL STRING FROM ABOVE
CEILING TO BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE
FOR PULLING CONDUCTORS AND PROVIDING APPROPRIATE
TEMINAL AT FACE PLATE.
3. ALL ELECTRICAL OUTLETS WITHIN 6'-0" OF WATER ARE TO BE GFI.
4. TENANT TO SUPPLY, INSTALL AND PAY FOR SECURITY SYSTEMS (I.E.
MAIN SECURITY CONTROL PANEL & MOTION DETECTORS.) MAIN
SECURITY CONTROL PANEL TO BE LOCATED IN THE ELECTRICAL
ROOM.
5. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. AFF TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE.
6. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING JUNCTION BOX LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES AND CARD READERS. ELECTRIC
STRIKES AND CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND ARE TYPICALLY NOT
SPECIFIED BY PARALLEL DESIGN GROUP.
GENERAL NOTESLEGEND
POWER OUTLET, DUPLEX
POWER OUTLET, QUADRUPLEX
WALL MOUNTED JUNCTION BOX
CEILING MOUNTED JUNCTION BOX
DATA/COMMUNICATION OUTLET
(PROVIDE BOX AND PULL STRING ONLY)
BOX, BLANK COVER PLATE
BOX, OPEN
P POWER AND DATA POLE
FLOOR BOX WITH JUNCTION BOX AND
DATA, FLUSH MOUNTED
FLOOR BOX WITH POWER AND DATA,
FLUSH MOUNTED
NEW
DEDICATED CIRCUIT
GROUND FAULT CIRCUIT INTERRUPT OUTLET
HEIGHT OF ELECTRICAL OR DATA DEVICE
N
DED
GFI
+44"
B
O
J
DATA
TV1
CEILING MOUNTED POWER & HDMIHD
HD FLOOR BOX WITH POWER, DATA, & HDMI
FLUSH MOUNTED
SPECIAL PLUG
DUPLEX AND DATA AT +60" AFF
KEYED NOTES
RANGE PLUGR
J
AREA NOT IN CONTRACT
AREA OF WORK
TV2 DUPLEX, DATA AND HDMI
AT +60" AFF
TV3 DUPLEX, DATA AND CABLE
AT +60" AFF
OPEN OFFICE
446
WORKROOM
418
OFFICE
441
OFFICE
439
OFFICE
438
LG. CONFERENCE
402
OFFICE
442
OFFICE
410
OFFICE
409
OFFICE
408
STORAGE
412
OFFICE
422
OFFICE
423
I.T.
424
SALES
433
WELLNESS
419
OFFICE
443
OFFICE
428
RECEPTION
401
OFFICE
429
OFFICE
430
OFFICE
431
OFFICE
432
FOCUS
416
FOCUS
406
BOARDROOM
404
MD. CONFERENCE
403
FOCUS
435
OFFICE
445 OFFICE
407
COATS
415
PANTRY
413
OFFICE
444
STG.
417
OFFICE
440
SOCIAL HUB
405
FOCUS
411
FOCUS
434
FOCUS
437
ELECTRICAL
427
JANITOR
426
IT/STG
425
MEN'S RR
420
WOMEN'S RR
421
SHAFT
414
BALCONY
450
1
2
3
3
3
3
3
3 4
4
4
5
5 5
6 6 6
6
6 6 6 6 6
6
7
83
9
9 9
10
11
5
5
5 5
1
4
11
12
5
5
13
5 5 5 5
5 5 5
1/8" = 1'-0"
POWER & DATA PLAN1
1 COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE
DEDICATED RECEPTACLE AS REQUIRED.
2 PROVIDE POWER AS NEEDED FOR DISHWASHER AND GARBAGE
DISPOSAL.
3 SEE BUILDING CORE AND SHELL DRAWINGS PROVIDED BY OTHERS
FOR ALL ELECTRICAL REQUIREMENTS IN THIS ROOM.
4 PROVIDE POWER AS NEEDED FOR TENANT PROVIDED
UNDERCOUNTER FRIDGE.
5 PROVIDE ELECTRICAL FOR TENANT PROVIDED WALL MOUNTED
TELEVISION. COORDINATE EXACT LOCATION AND REQUIREMENTS
WITH TENANT.
6 PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE
SYSTEM. COORDINATE EXACT LOCATION AND REQUIREMENTS
WITH TENANT'S FURNITURE VENDOR.
7 PROVIDE FLUSH MOUNT FLOOR CORE DRILL FOR JUNCTION BOX
AND DATA. COORDINATE EXACT LOCATION AND REQUIREMENTS
WITH TENANT'S FURNITURE VENDOR.
8 CONFIRM ALL ELECTRICAL REQUIREMENTS AND LOCATIONS WITH
TENANT IN THIS ROOM.
9 PROVIDE FLUSH MOUNT FLOOR CORE DRILL FOR POWER AND
DATA. COORDINATE EXACT LOCATION AND REQUIREMENTS AND
LOCATION WITH TENANT'S FURNITURE VENDOR.
10 INSIDE OF PANTRY CABINET, PROVIDE DEDICATED DUPLEX FOR
TENANT PROVIDED MICROWAVE AND DUPLEX FOR TENANT
PROVIDED FRIDGE. CONFIRM EXACT REQUIREMENTS WITH TENANT.
11 INSIDE OF PANTRY CABINET, PROVIDE ALL REQUIRED ELECTRICAL
FOR TENANT PROVIDED COFFEE MAKER AND ICE/WATER MACHINE.
CONFIRM EXACT REQUIREMENTS WITH TENANT.
12 PROVIDE POWER AS NEEDED FOR OVEN RANGE AND RANGE HOOD.
13 OUTLETS TO BE INSTALLED HORIZONTALLY RIGHT BELOW
COUNTER ON VERTICAL FACE OF ISLAND BASE.[ PROJECT NUMBER ][DATE][DRAWN BY][CHECKED BY][ P ][ W ]N
ALL DESIGNS, CONCEPTS, ARRANGEMENTS AND PLANS
INDICATED OR REPRESENTED BY THESE DRAWINGS ARE
OWNED BY PARALLEL DESIGN GROUP, INC. AND SHALL NOT BE
USED BY OR DISCLOSED TO ANY PERSON, FIRM OR CORP. FOR
ANY REASON WHATSOEVER WITHOUT THE WRITTEN CONSENT
OF PARALLEL DESIGN GROUP INC.
CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS ON THE JOB SITE. PARALLEL DESIGN GROUP INC.
MUST BE NOTIFIED OF ANY DISCREPANCIES OR VARIATIONS
FROM THE DIMENSIONS SHOWN ON THE PLAN.8940 River Crossing Blvd. Ste 150Indianapolis, IN 46240ParallelDG.com317.721.4399A301
POWER AND DATA
PLAN2022.19210.21.22ASSURED PARTNERS1 E MAIN STREET CARMEL, INDIANA 46032FOURTH FLOORSF/LWBDREVISION SCHEDULENO.DATEDESCRIPTION03/08/23