Loading...
HomeMy WebLinkAboutC601 - STORM SEWER PLAN AND PROFILE825 830 835 840 845 850 855 825 830 835 840 845 850 855 -0+100+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 8+60 -0+100+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 8+60 33' of 12" RCP @ 0.31% 85' of 18" RCP @ 0.18% 165' of 18" RCP @ 0.18% 14' of 15" RCP @ 0.56% 25' of 24" RCP @ 0.16% 191' of 18" RCP @ 0.18% 119' of 24" RCP @ 0.17%STRUCTURE #ST-6T.C. 844.43INV IN:831.89 18" (NW)INV OUT:831.79 18" (E)STRUCTURE #ST-4T.C. 837.10INV IN:831.44 15" (N)INV IN:831.44 18" (W)INV OUT:831.34 24" (E)STRUCTURE #ST-7T.C. 837.65INV IN:832.28 18" (NW)INV OUT:832.18 18" (SE)STRUCTURE #ST-3T.C. 837.03INV IN:831.30 24" (W)INV OUT:831.20 24" (E)STRUCTURE #ST-9T.C. 837.40INV IN:834.42 12" (S)INV OUT:834.42 15" (NE)STRUCTURE #ST-10T.C. 837.52INV OUT:834.52 12" (N)STRUCTURE #ST-8T.C. 836.44INV IN:832.53 18" (W)INV OUT:832.43 18" (SE)STRUCTURE #ST-2 END SECTION INV:831.00 24" RCPSTRUCTURE #ST-11T.C. 836.60INV IN:834.16 15" (SW)INV OUT:832.82 18" (E)163' of 18" RCP @ 0.18% 29' of 15" RCP @ 0.91% 4' of 15" RCP @ 1.88%845841842843844840845838839841842843844846838 850 847 84 8 849840838839840 845 839 841 842 843 844 846 84084584184284384484684733' of 12" RCP @ 0.31% 85' of 18" RCP @ 0.18% 16 5 ' o f 1 8 " R C P @ 0 . 1 8 % 14' of 15" RCP @ 0.56% 25' of 24" RCP @ 0.16% 8 3 0 8358 3 1 8 3 2 83 3 834 836837825822823823823824826827828829GAS29' of 15" RCP @ 0.91%163' of 18" RCP @ 0.18% 8 3 9 837 838 839840 841 4' of 15" RCP @ 1.88% 119' of 24" RCP @ 0.17% 191' of 1 8 " R C P @ 0 . 1 8 % 15' of 12" RCP @ 0.34% O O O O OO O OOOOOA B C D E F G H J K L 151413121110987654321 151413121110987654321 A B C D E F G H J K L PRELIMINARY NOT FOR CONSTRUCTION This drawing is for review purposes only. 1100 Sycamore Street, Suite 200 Cincinnati, Ohio 45202 - Ph: 513.984.1070 702 N. Capitol Avenue Indianapolis, Indiana 46204 Ph: 317.636.3980 www.luminaut.com 13295 Illinois Street Suite 142 Carmel, IN 46032 ENGINEERING, LLC SNELLING Ph: (317) 697-0180 www.snellingeng.com IMI Headquarters New Build 10901 Illinois St. Carmel, IN 46032 IN22046 01/18/2023 GSS SEE PLAN 1 TAC REVISIONS 3/8/23 C601 Hydraulic Grade Line (Typ) 1 STORM SEWER PLAN N SCALE : 1" = 30' 60 GRAPHIC SCALE IN FEET 300 90 C601 2 STORM SEWER PROFILE SCALE : 1"=30' (H) - 1"=3'(V)C601 STORM SEWER PLAN AND PROFILE EXISTING GAS MAIN LOWER OR RELOCATE AS NECESSARY COORDINATE WITH CENTERPOINT ENERGY* EXISTING MERIDIAN SUBURBAN DRAIN STORM SEWER PIPE TO BE REMOVED UPSTREAM OF POND OUTLET (STR. #EX-2) STR. #ST-11 STR. #ST-10 STR. #ST-10 STR. #ST-8 STR. #ST-7 STR. #ST-6 STR. #ST-12 STR. #ST-2 STR. #ST-3 (AQUASWIRL AS-5) STR. #ST-4 STR. #ST-5 8" WATER 8" WATER* EXISTING GAS MAIN* (CLASS V RCP REQ'D) (CLASS V RCP REQ'D) (CLASS V RCP REQ'D) 1