HomeMy WebLinkAboutC601 - STORM SEWER PLAN AND PROFILE825
830
835
840
845
850
855
825
830
835
840
845
850
855
-0+100+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 8+60
-0+100+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 8+60
33' of 12" RCP @ 0.31%
85' of 18" RCP @ 0.18%
165' of 18" RCP @ 0.18%
14' of 15" RCP @ 0.56%
25' of 24" RCP @ 0.16%
191' of 18" RCP @ 0.18%
119' of 24" RCP @ 0.17%STRUCTURE #ST-6T.C. 844.43INV IN:831.89 18" (NW)INV OUT:831.79 18" (E)STRUCTURE #ST-4T.C. 837.10INV IN:831.44 15" (N)INV IN:831.44 18" (W)INV OUT:831.34 24" (E)STRUCTURE #ST-7T.C. 837.65INV IN:832.28 18" (NW)INV OUT:832.18 18" (SE)STRUCTURE #ST-3T.C. 837.03INV IN:831.30 24" (W)INV OUT:831.20 24" (E)STRUCTURE #ST-9T.C. 837.40INV IN:834.42 12" (S)INV OUT:834.42 15" (NE)STRUCTURE #ST-10T.C. 837.52INV OUT:834.52 12" (N)STRUCTURE #ST-8T.C. 836.44INV IN:832.53 18" (W)INV OUT:832.43 18" (SE)STRUCTURE #ST-2
END SECTION
INV:831.00 24" RCPSTRUCTURE #ST-11T.C. 836.60INV IN:834.16 15" (SW)INV OUT:832.82 18" (E)163' of 18" RCP @ 0.18%
29' of 15" RCP @ 0.91%
4' of 15" RCP @ 1.88%845841842843844840845838839841842843844846838
850
847
84
8
849840838839840
845
839
841 842 843 844
846
84084584184284384484684733' of 12" RCP @ 0.31%
85' of 18" RCP @ 0.18%
16
5
'
o
f
1
8
"
R
C
P
@
0
.
1
8
%
14' of 15" RCP @ 0.56%
25' of 24" RCP @ 0.16%
8
3
0
8358
3
1
8
3
2
83
3
834
836837825822823823823824826827828829GAS29' of 15" RCP @ 0.91%163' of 18" RCP @ 0.18%
8
3
9
837
838
839840
841
4' of 15" RCP @ 1.88%
119' of 24" RCP @ 0.17%
191' of 1
8
"
R
C
P
@
0
.
1
8
%
15' of 12" RCP @ 0.34%
O
O
O
O
OO
O
OOOOOA
B
C
D
E
F
G
H
J
K
L
151413121110987654321
151413121110987654321
A
B
C
D
E
F
G
H
J
K
L
PRELIMINARY
NOT FOR CONSTRUCTION
This drawing is for
review purposes only.
1100 Sycamore Street, Suite 200
Cincinnati, Ohio 45202 - Ph: 513.984.1070
702 N. Capitol Avenue
Indianapolis, Indiana 46204
Ph: 317.636.3980
www.luminaut.com
13295 Illinois Street
Suite 142
Carmel, IN 46032
ENGINEERING, LLC
SNELLING
Ph: (317) 697-0180
www.snellingeng.com
IMI Headquarters
New Build
10901 Illinois St.
Carmel, IN 46032
IN22046
01/18/2023
GSS
SEE PLAN
1 TAC REVISIONS 3/8/23
C601
Hydraulic Grade Line (Typ)
1 STORM SEWER PLAN
N
SCALE : 1" = 30'
60
GRAPHIC SCALE IN FEET
300 90
C601
2 STORM SEWER PROFILE
SCALE : 1"=30' (H) - 1"=3'(V)C601
STORM SEWER
PLAN AND
PROFILE
EXISTING GAS MAIN
LOWER OR RELOCATE
AS NECESSARY
COORDINATE WITH
CENTERPOINT ENERGY*
EXISTING MERIDIAN SUBURBAN DRAIN
STORM SEWER PIPE TO BE REMOVED
UPSTREAM OF POND OUTLET (STR. #EX-2)
STR. #ST-11
STR. #ST-10
STR. #ST-10
STR. #ST-8
STR. #ST-7
STR. #ST-6
STR. #ST-12
STR. #ST-2
STR. #ST-3
(AQUASWIRL AS-5)
STR. #ST-4
STR. #ST-5
8" WATER
8" WATER*
EXISTING GAS MAIN*
(CLASS V RCP REQ'D)
(CLASS V RCP REQ'D)
(CLASS V RCP REQ'D)
1