Loading...
HomeMy WebLinkAboutC803 - CONSTRUCTION DETAILSA B C D E F G H J K L 151413121110987654321 151413121110987654321 A B C D E F G H J K L PRELIMINARY NOT FOR CONSTRUCTION This drawing is for review purposes only. 1100 Sycamore Street, Suite 200 Cincinnati, Ohio 45202 - Ph: 513.984.1070 702 N. Capitol Avenue Indianapolis, Indiana 46204 Ph: 317.636.3980 www.luminaut.com 13295 Illinois Street Suite 142 Carmel, IN 46032 ENGINEERING, LLC SNELLING Ph: (317) 697-0180 www.snellingeng.com IMI Headquarters New Build 10901 Illinois St. Carmel, IN 46032 IN22046 01/18/2023 GSS SEE PLAN 1 TAC REVISIONS 3/8/23 C803 CONSTRUCTION DETAILS INLET TYPE "J" DETAIL TRENCH DRAIN DETAIL 1'-10" PVC ROOF DRAIN BEDDING DETAIL INLET TYPE "A" DETAIL STORM PIPE UTILITY CONTRACTOR 1/8 BEND CONCRETE PAD 8"THICK x 2'-0" SQUARE BY SITE CLEAN-OUT PLUG US FOUNDARY COVER USF NO. 7261 STORM CLEAN-OUT DETAIL SECTION BB6" WIRE MESH @ 0.07 SQ.IN./L.F., AND CLASS II WALL "B". 97 3/4 97 3/4 73 3/4 73 1/2 73 1/2 100 72 7/8 NOTE: REINFORCING SHALL COMPLY WITH ASTMC-76, 60 396530875060 6 1/2 7 1/2 84 78 8 72 66 7 10630 16350 14430 12520 7 6 1/2 5 1/2 6 24 24 34 24 78 78 78 78 21 21 21 21 WALL (GROVE-OUTLET END) TONGUE- INLET END) 5 1/2 4 1/2 3 3/4 3 1/2 3 1/4 2 3/4 2 1/2 2 1/4 21 548 54 42 36 4 33 30 24 27 3 15 18 12 DIA. 2 35 382 1/4 91280 13 1/2 10 1/2 9 1/2 4 1/4 4 3/4 3 3/4 3 1/2 246550 8040 27 5380 4100 21 15 2 1/2 3 3/8 3 2 1/2 3150 2190 12 1620 1930 72 65 63 63 26 35 34 3/4 35 58 1/2 54 43 1/2 48 25 1/2 39 1/4 19 3/4 30 WT.SEC. 2 2 1/2 G/T 1 1/2 6740 990 9 530 4 A 27 27 24 B 46 46 48 7/8 C 61 36 3/4 6 3/4249996 35 11/16 44 13/16 41 15/16 38 5/8 99 99 120 114 99 99 108 102 85 79 73 67 24 24 24 24 8 1/2 9 7 1/4 7 3/4 22 16 1/8 4137342 23 3/4 32 7/8 28 1/8 22 1/16 27 1/4 18 5/16 17 3/4 16 11/16 98 84 90 98 78 72 49 55 43 37 66 60 48 54 34 31 25 28 22 24 22 20 5 3/4 6 1/4 5 1/2 5 1/2 14 1/2 17 1/2 15 14 4 1/2 5 1/2 5 4 1/2 10 1/16 15 1/2 12 1/2 DIA.+1 73 30 73 36 D 24 E 16 19 13 R-1 11 12 R-2 9 3 1/2 4 SKIRT 3 1/2 PER SIDE 1-1/2"R 1/32" TAPER/INCH WALL 1-1/2"R SKIRT WALLWALLWALLDIA.A WALLG/T 3" BC DIA. +12'AR-2 BDB A ER-1 HORIZONTAL FLARE E R-1 DIAWALL HORIZONTAL FLAREDIA CONCRETE END SECTION DETAIL 22'3'3' TOP OF BANK ELEV. 838.0 ELEV. 837.0 3 1 1 3 EMERGENCY SPILLWAY SECTION TRASH GUARD NON-CORROSIVE 6" CONCRETE PRECAST (CLASS 'A' CONCRETE)8"5.02'6"6"24"6"12" RCP OUT INV. 830.50 (NORTH) 7" DIA. ORIFICE INV. ELEV. 833.50 (EAST) TOP ELEV. 835.52 COMPACTED SUBGRADE #53 STONE BEDDING STRUCTURE #ST-1 POND OUTLET 4.5" DIA. ORIFICE INV. ELEV. 830.50 (EAST) SIDE WALL GRATES BY TRASHRACKS.COM OR APPROVED EQUAL REQ'D TO COVER ALL ORIFICES. MOUNT TO STRUCTURE PER MANUFACTURER RECOMMENDATIONS.3:13: 1 Top of Bank Elev. 838.00 Normal Pool Elev. 830.50 Bottom Elev. 819.50 10' SAFETY LEDGE 2:12:112" Lowest Adjacent Street 840± (U.S. 31) Building F.F. 839.00 (Subsurface Garage) 100-year Elev. 835.52 Erosion Control Matting (all sides) Compacted clay liner per NRCS Conservation Practice Standard Pond Sealing or Lining – Compacted Soil Treatment, Oct. 2016 or Latest Edition. POND CROSS SECTION "Do Not Mow or Spray" Signage (see sheet C403 for locations) Not to ScaleC803 04 Not to ScaleC803 05 Not to ScaleC803 01 Not to ScaleC803 03 Not to ScaleC803 07 Not to ScaleC803 06 Not to ScaleC803 08 Not to ScaleC803 09 Not to ScaleC803 02 2733 Kanasita Drive, Suite 111, Chattanooga, TN 37343 Phone (888) 344-9044 Fax (423) 826-2112 www.aquashieldinc.com Structure #: Drawn By: Scale: Date: Rvwed Rvw. Date U.S. Patent No. 6524473 and other Patent Pending Aqua-Swirl® Concentrator As Shown OFlores 9/15/2022Standard Detail AS-7 BYP CW AS-7 STD Aqua-Swirl® Polymer Coated Steel (PCS) Stormwater Treatment System 12 in [305 mm] Manhole Frame & Cover Detail For Non-Traffic Areas Only NTS 48 in [1219 mm] Min. Gravel Backfill Concrete Wrap Compressible Expansion Joint Material to a minimum 1/2-inch [13 mm] thickness around top of riser to allow transfer of inadvertent loading from manhole cover to concrete slab. Riser Soil Cover Frame 1/2 in [13 mm] 1/2 in [13 mm] Place small amount of concrete [3,000 psi [20 MPa] (min)] to support and level manhole frame. DO NOT allow manhole frame to rest upon riser. Backfill (90% Proctor Density) 8 in [203 mm] 4 1/2 in [114 mm] Unless other traffic barriers are present, bollards shall be placed around access riser(s) in non-traffic areas to prevent inadvertent loading by maintenance vehicles. Manhole Frame & Cover Detail For Traffic Loading Areas NTS Cover Frame 48 in [1219 mm] Min. Backfill (90% Proctor Density) 3,000 psi [20 MPa] (min) Concrete #4 [13 mm] Rebar @ 6 in [152 mm] Each Way 30 in [762 mm] Riser 1/2 in [13 mm] 4 1/2 in [114 mm] 14 in [356 mm] 1/2 in [13 mm] Thick Expansion Joint Material If traffic loading (HS-25) is required or anticipated, a 4-foot [1.22 m] diameter, 14-inch [356 mm] thick reinforced concrete pad must be placed over the Stormwater Treatment System Riser to support and level the manhole frame, as shown. The top of riser pipe must be wrapped with compressible expansion joint material to a minimum 1/2-inch [13 mm] thickness to allow transfer of wheel loads from manhole cover to concrete slab. Manhole cover shall bear on concrete slab and not on riser pipe. The concrete slab shall have a minimum strength of 3,000 psi [20 MPa] and be reinforced with #4 [13 mm] reinforcing steel as shown. Minimum cover over reinforcing steel shall be 1-inch [25 mm]. Top of manhole cover and concrete slab shall be level with finish grade. Please see accompanied Aqua-Swirl® specification notes. See Site Plan for actual system orientation. Approximate dry (pick) weight: 3800 lbs [1700 kg]. Projected View SCALE 1:80 Plan View SCALE 1:40 Backfill shall extend at least 18 inches [457 mm] outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser) extending laterally to undisturbed soils. (See MH Detail Below) Pipe coupling by Contractor. 12 in [305 mm] long Stub-out by Manufacturer. Octagonal Base Plate Pipe coupling by Contractor. 12 in [305 mm] long Stub-out by Manufacturer. Elevation View SCALE 1:40 Varies Varies Internal Baffles el. Varies Inlet/Outlet Invert el. Varies el. Varies Grade (Rim) el. Varies OutletInletRiser Ø90 in [Ø229 mm] 102 in [2591 mm] 102 in [2591 mm] 68 in [1727 mm] 114 in [2896 mm] 5 in MH Frame [127 mm] n30 in [762 mm] n30 in [762 mm] n30 in [762 mm] Rim elevations to match finish grade. n90 in [2286 mm] 1 1 As an alternative, 42 in [1067 mm] diameter, HS-20/25 rated precast concrete rings may be substituted. 14 in [356 mm] thickness must be maintained. AS-7 BYP inlet/outlet pipe size ranges from 15 in [381 mm] to 42 in [1067 mm]. AS-7 chamber height may vary from 95 in [2413 mm] to 122 in [3099 mm], depending on inlet/outlet pipe size. Orientation may vary from a minimum of 90° to a maximum of 180°. Manhole Frame and Cover by Manufacturer. (See Details) 180° 2 3 4 2 3 4 2 Band Coupler by Manufacturer. (as needed) Lifting Lug Backfill Bedding Undisturbed soil 18 in [457 mm] 6 in [152 mm] Lifting Lug 2733 Kanasita Drive, Suite 111, Chattanooga, TN 37343 Phone (888) 344-9044 Fax (423) 826-2112 www.aquashieldinc.com Structure #: Drawn By: Scale: Date: Rvwed Rvw. Date U.S. Patent No. 6524473 and other Patent Pending Aqua-Swirl® Concentrator As Shown OFlores 9/15/2022Standard Detail AS-4 BYP CW AS-4 STD Aqua-Swirl® Polymer Coated Steel (PCS) Stormwater Treatment System 12 in [305 mm] Manhole Frame & Cover Detail For Non-Traffic Areas Only NTS 48 in [1219 mm] Min. Gravel Backfill Concrete Wrap Compressible Expansion Joint Material to a minimum 1/2-inch [13 mm] thickness around top of riser to allow transfer of inadvertent loading from manhole cover to concrete slab. Riser Soil Cover Frame 1/2 in [13 mm] 1/2 in [13 mm] Place small amount of concrete [3,000 psi [20 MPa] (min)] to support and level manhole frame. DO NOT allow manhole frame to rest upon riser. Backfill (90% Proctor Density) 8 in [203 mm] 4 1/2 in [114 mm] Unless other traffic barriers are present, bollards shall be placed around access riser(s) in non-traffic areas to prevent inadvertent loading by maintenance vehicles. Manhole Frame & Cover Detail For Traffic Loading Areas NTS Cover Frame 48 in [1219 mm] Min. Backfill (90% Proctor Density) 3,000 psi [20 MPa] (min) Concrete #4 [13 mm] Rebar @ 6 in [152 mm] Each Way 30 in [762 mm] Riser 1/2 in [13 mm] 4 1/2 in [114 mm] 14 in [356 mm] 1/2 in [13 mm] Thick Expansion Joint Material If traffic loading (HS-25) is required or anticipated, a 4-foot [1.22 m] diameter, 14-inch [356 mm] thick reinforced concrete pad must be placed over the Stormwater Treatment System Riser to support and level the manhole frame, as shown. The top of riser pipe must be wrapped with compressible expansion joint material to a minimum 1/2-inch [13 mm] thickness to allow transfer of wheel loads from manhole cover to concrete slab. Manhole cover shall bear on concrete slab and not on riser pipe. The concrete slab shall have a minimum strength of 3,000 psi [20 MPa] and be reinforced with #4 [13 mm] reinforcing steel as shown. Minimum cover over reinforcing steel shall be 1-inch [25 mm]. Top of manhole cover and concrete slab shall be level with finish grade. Please see accompanied Aqua-Swirl® specification notes. See Site Plan for actual system orientation. Approximate dry (pick) weight: 2000 lbs [900 kg]. Projected View SCALE 1:80 Plan View SCALE 1:40 Backfill shall extend at least 18 inches [457 mm] outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser) extending laterally to undisturbed soils. (See MH Detail Below) Pipe coupling by Contractor. 12 in [305 mm] long Stub-out by Manufacturer. Octagonal Base Plate Pipe coupling by Contractor. 12 in [305 mm] long Stub-out by Manufacturer. Elevation View SCALE 1:40 Varies Varies Internal Baffles el. Varies Inlet/Outlet Invert el. Varies el. Varies Grade (Rim) el. Varies OutletInletRiser Ø54 in [Ø1375 mm] 66 in [1676 mm] 66 in [1676 mm] 68 in [1727 mm] 104 in [2642 mm] 5 in MH Frame [127 mm] n30 in [762 mm] n21 in [533 mm] n21 in [533 mm] Rim elevations to match finish grade. n54 in [1372 mm] 1 1 As an alternative, 42 in [1067 mm] diameter, HS-20/25 rated precast concrete rings may be substituted. 14 in [356 mm] thickness must be maintained. AS-4 BYP inlet/outlet pipe size ranges from 12 in [305 mm] to 27 in [686 mm]. AS-4 chamber height may vary from 92 in [2337 mm] to 107 in [2718 mm], depending on inlet/outlet pipe size. Orientation may vary from a minimum of 90° to a maximum of 180°. Manhole Frame and Cover by Manufacturer. (See Details) 180° 2 3 4 2 3 4 2 Band Coupler by Manufacturer. (as needed)Lifting Lugs Backfill Bedding Undisturbed soil 18 in [457 mm] 6 in [152 mm] Lifting Lugs 1 1 1 Native Vegetation (all sides) Wet Mesic Mix from Elev. 830.5 to 838