Loading...
HomeMy WebLinkAboutC301 - GRADING PLAN NORTHEAST840845850 8418428438448 4 6 847 848 849 8 5 0 851 8 5 1 840 845 841 842 843 844 846 84 7 848 849 845 850 842843844 846847 848849 853.00 (FIRST FLOOR) 839.00 (LOWER LEVEL) M.F.P.G. = 839.0 L.A.G. = 839.0 INV IN:832.28 18" (NW) INV OUT:832.18 18" (SE) STRUCTURE #ST-24 T.C. 848.94 INV OUT:843.87 12" (E) STRUCTURE #ST-22 T.C. 848.72 INV IN:842.20 12" (N) INV OUT:840.83 12" (SE) 39' of 12" RCP @ 1.85% STRUCTURE #ST-21 T.C. 843.09 INV IN:836.97 12" (NW) INV IN:836.60 15" (S) INV OUT:836.50 15" (E) 84' of 12" RCP @ 4.60% STRUCTURE #ST-19 T.C. 836.96 INV IN:833.38 15" (W) INV OUT:833.10 18" (S) 27' of 15" RCP @ 1.55% STRUCTURE #ST-17 T.C. 838.08 INV IN:832.22 18" (N) INV OUT:831.72 24" (SW) 189' of 18" RCP @ 0.19% STRUCTURE #ST-14 END SECTION INV:831.00 24" RCP 23' of 24" RCP @ 0.27% STRUCTURE #ST-23 T.C. 848.24 INV IN:843.15 12" (W) INV OUT:843.05 12" (S) 27' of 12" RCP @ 3.17% 67' of 15" R C P @ 0 . 3 0 % STRUCTURE #ST-18 T.C. 836.75 INV IN:832.75 18" (N) INV OUT:832.75 18" (S) STRUCTURE #ST-15 T.C. 838.22 INV IN:831.50 24" (NW) INV OUT:831.40 24" (SE) 840 838 839 838 838 839 839 STRUCTURE #ST-16 T.C. 838.33 INV IN:831.66 24" (NE) INV OUT:831.56 24" (SE) STRUCTURE #ST-26 T.C. 838.95 INV OUT:837.00 15" (N) STRUCTURE #ST-25 T.C. 839.35 INV IN:836.90 15" (S) INV OUT:836.80 15" (N) 17' of 15" RCP @ 0.58% STRUCTURE #ST-20 T.C. 842.50 INV IN:836.08 15" (W) INV OUT:835.28 15" (E) 30' UTILITY, DRAINAGE AND BMP ACCESS EASEMENTBMP EASEMENT PONDING ELEV. 837.80 PONDING DEPTH 1.05' PONDING ELEV. 837.80 PONDING DEPTH 0.84' PONDING ELEV. 849.11 PONDING DEPTH 0.20'□□□□□□□□□□□□□□□□□10' SAFETY LEDGE FLOW-THROUGH BMP (ONLINE) PVC ROOF DRAIN SEE PLUMBING PLANS FOR SIZE STORM CLEAN-OUT T.C. 838.90 INV. 832.50 O O O O O O O O O OOOOOOOOOPONDING ELEV. 839.00 PONDING DEPTH 0.05'CLCL CLCLCLCLCLCLCLCLCL CL CL CLCLCLCL CLCLCLCLCLCLCLCL CL CL CL CL CL CL CL CLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLCLOOOOOOA B C D E F G H J K L 151413121110987654321 151413121110987654321 A B C D E F G H J K L PRELIMINARY NOT FOR CONSTRUCTION This drawing is for review purposes only. 1100 Sycamore Street, Suite 200 Cincinnati, Ohio 45202 - Ph: 513.984.1070 702 N. Capitol Avenue Indianapolis, Indiana 46204 Ph: 317.636.3980 www.luminaut.com 13295 Illinois Street Suite 142 Carmel, IN 46032 ENGINEERING, LLC SNELLING Ph: (317) 697-0180 www.snellingeng.com IMI Headquarters New Build 10901 Illinois St. Carmel, IN 46032 IN22046 01/18/2023 GSS SEE PLAN 1 TAC REVISIONS 3/8/23 1 GRADING PLAN - NORTHEAST N60 GRAPHIC SCALE IN FEET 300 90 SCALE : 1" = 30'C301 C301 GRADING PLAN NORTHEAST GRADING NOTES 1.PROVIDE POSITIVE DRAINAGE IN ALL AREAS. PAVING CONTRACTOR SHALL TEST FOR ANY PONDING CONDITIONS AFTER INSTALLATION AND CORRECT. 2.PROVIDE SMOOTH TRANSITION FROM NEW AREAS TO EXISTING FEATURES AS NECESSARY. 3.ALL AREAS WHERE PROPOSED ASPHALT PAVEMENT MEETS THE EXISTING PAVEMENT THE EXISTING PAVEMENT EDGE SHALL BE PROPERLY SEALED WITH A TACK COAT MATERIAL. 4.THE EXCAVATING CONTRACTOR MUST TAKE PARTICULAR CARE WHILE EXCAVATING AROUND EXISTING TREES SO NOT TO DISTURB AND TO MINIMIZE OR ELIMINATE DAMAGE TO ROOT SYSTEM. 5.THE EXCAVATING CONTRACTOR MUST TAKE PARTICULAR CARE WHEN EXCAVATING IN AND AROUND EXISTING UTILITY LINES AND EQUIPMENT. VERIFY COVER REQUIREMENTS BY UTILITY CONTRACTORS AND/OR UTILITY COMPANIES SO NOT TO CAUSE DAMAGE. 6.THE EXCAVATING CONTRACTOR OR LANDSCAPING CONTRACTOR SHALL INSTALL THE FINISH GRADE AT 1/2" BELOW PAVEMENTS WHEN SHEET DRAINAGE IS PROPOSED ACROSS THAT SEEDED AREA. 7.ALL AREAS WHERE THE EXISTING PAVEMENT OR PAVEMENTS ARE DAMAGED DURING CONSTRUCTION FROM TRAFFIC BY THE GENERAL CONTRACTOR, SUBCONTRACTORS OR SUPPLIERS, SHALL BE RESURFACED OR RECONSTRUCTED AT LEAST TO THEIR ORIGINAL CONDITION AFTER THE CONSTRUCTION WORK IS COMPLETED. PROPOSED GROUND CONTOUR PROPOSED SPOT ELEVATION (TOP OF CURB OVER BOTTOM OF CURB) PROPOSED SPOT ELEVATION MINIMUM FLOOD PROTECTION GRADE LOWEST ADJACENT GRADE PROPOSED STORM SEWER PIPE PROPOSED ROOF DRAIN OR AREA DRAIN PIPE PROPOSED PERFORATED SUBDRAIN PROPOSED STORM MANHOLE PROPOSED STORM INLET CL CONSTRUCTION LIMITS M.F.P.G. L.A.G. LEGEND FLOOD STATEMENT: BY GRAPHIC PLOTTING ONLY, THIS PROPERTY IS LOCATED IN ZONE X (AREAS OF MINIMAL FLOODING) OF THE FLOOD INSURANCE RATE MAP, COMMUNITY PANEL NO. 18057C0208G, WHICH BEARS AN EFFECTIVE DATE OF NOVEMBER 19, 2014 AND IS NOT IN A SPECIAL FLOOD HAZARD AREA. STORM SEWER STATEMENT: ALL STORM SEWERS SHALL BE PRIVATE. THE LOWEST ADJACENT GRADE (L.A.G.) IS THE LOWEST GRADE ADJACENT TO THE BUILDING WHERE THE SOIL MEETS THE FOUNDATION AROUND THE OUTSIDE OF THE STRUCTURE (INCLUDING STRUCTURAL MEMBERS SUCH AS PATIOS, DECKS, PORCHES, SUPPORT POSTS OR PIERS, AND RIM OF THE WINDOW WELL). L.A.G. SHALL BE A MINIMUM OF 2' ABOVE THE MAJOR FLOOD SOURCE OR MAJOR FLOOD ROUTE, 2' ABOVE THE SPILLWAY OF THE DETENTION FACILITY, AND 1' ABOVE THE LOCAL FLOOD SOURCE OR LOCAL FLOOD ROUTE. MINIMUM FLOOD PROTECTION GRADE (M.F.P.G.) OF ALL STRUCTURES FRONTING A POND OR OPEN DITCH SHALL BE NO LESS THAN 2 FEET ABOVE ANY ADJACENT 100-YEAR LOCAL OR REGIONAL FLOOD ELEVATIONS, WHICHEVER IS GREATER, FOR ALL WINDOWS, DOORS, PIPE ENTRANCES, WINDOW WELLS, AND ANY OTHER STRUCTURE MEMBER WHERE FLOODWATERS CAN ENTER A BUILDING. KEY MAP ORIGINATING BENCHMARK STATION NAME - HCBR 194 CIVIL TOWNSHIP - CLAY USGS QUAD - CARMEL DESCRIBED HAMILTON CO SURVEYORS OFFICE HAMILTON COUNTY GEODETIC CONTROL DISK IN THE NORTHWEST CORNER OF CONCRETE BRIDGE DECK OF BRIDGE CARRYING RANGELINE ROAD OVER LITTLE COOL CREEK ELEVATION = 811.76 (NAVD 88) PONDING AREA WITH ALL PIPES CLOGGED 1