HomeMy WebLinkAboutS001 - GENERAL NOTES AND ABBREVIATIONSADDL ADDITIONAL
ADJ ADJACENT
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATE
AR ANCHOR ROD
ARCH ARCHITECTURAL
B PL BASE PLATE
B/ BOTTOM OF
BFR BLENDED FIBER
REINFORCING
BLDG BUILDING
BLKG BLOCK (ING)
BOT BOTTOM
BRG BEARING
BSMT BASEMENT
BTWN BETWEEN
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
CONN CONNECT (ION)
CONST JT CONSTRUCTION JOINT
CONT CONTINUOUS OR CONTINUE
COORD COORDINATE
CS COLUMN STRIP
CU YD CUBIC YARD
DET DETAIL
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DL DEAD LOAD
DWG DRAWING
EA EACH
EE EACH END
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EOBP EDGE OF BENT PLATE
EOD EDGE OF DECK
EOP EDGE OF PLATE
EOS EDGE OF SLAB
EQ EQUAL
ES EACH SIDE
EW EACH WAY
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FD FLOOR DRAIN
FDTN FOUNDATION
FLR FLOOR
FP FULL PENETRATION
FS FAR SIDE
FT FOOT/FEET
FTG FOOTING
GA GAGE
GALV GALVANIZED
GB GRADE BEAM
GC GENERAL CONTRACTOR
HORIZ HORIZONTAL
HP HIGH POINT
HS HIGH STRENGTH
HSS HOLLOW STRUCTURAL
SECTION
HT HEIGHT
ID INSIDE DIAMETER
IF INSIDE FACE
INFO INFORMATION
INSUL INSULATED (ION)
INV INVERT
JT JOINT
k KIPS
L ANGLE
LBS POUNDS
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LP LOW POINT
LSH LONG SIDE HORIZONTAL
LSV LONG SIDE VERTICAL
LTWT LIGHT WEIGHT
LW LONG WAY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEP MECHANICAL ELECTRICAL &
PLUMBING
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MS MIDDLE STRIP
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NS NEAR SIDE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OPNG OPENING
PC PILE CAP
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PEN PENETRATION
PL PLATE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POST TENSION
QTY QUANTITY
R RADIUS
RD ROOF DRAIN
REF REFERENCE
REINF REINFORCE (D) (ING)
REQD REQUIRED
REV REVISION
RO ROUGH OPENING
SC SLIP CRITICAL
SECT SECTION
SIM SIMILAR
SJ SEISMIC JOINT
SOG SLAB ON GROUND
SPEC SPECIFICATIONS
SQ SQUARE
SST STAINLESS STEEL
STBC STRU THERMAL BREAK CONN
STD STANDARD
STIFF STIFFENER
STL STEEL
STRUCT STRUCTURAL
SW SHORT WAY
SYMM SYMMETRICAL
T/ TOP OF
T&B TOP AND BOTTOM
THK THICK (NESS)
TRANS TRANSVERSE
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VIF VERIFY IN FIELD
W WIDE FLANGE SECTION
W/ WITH
W/O WITHOUT
WD WOOD
WP WORK POINT
WT TEE SECTION
WWR WELDED WIRE
REINFORCEMENT
REINFORCING STEEL MATERIAL GRADE
TYPICAL BARS
WELDED WIRE REINFORCING
BLENDED FIBER REINFORCING:
ASTM A615, GRADE 60
ASTM A1064
CONCRETE COVER FOR REINFORCING STEEL
CONCRETE CAST AGAINST EARTH OR FILL
No. 6 THRU No. 18
No. 5 AND SMALLER
SLABS ON GROUND
CONCRETE NOT EXPOSED TO WEATHER
OR IN CONTACT WITH GROUND:
3"
WELDED BARS ASTM A706, GRADE 60
CONCRETE EXPOSED TO EARTH AND WEATHER:
POLYPROPYLENE FIBERS
STEEL FIBERS ASTM A820 TYPE I
ASTM C116 TYPE I AND II
2"
1 1/2"
MIDDLE
SLAB AND WALLS:
No. 14 AND No. 18 BARS
No. 11 AND SMALLER
COLUMNS AND PIERS:
PRIMARY REINFORCING, TIES,
STIRRUPS, AND SPIRALS
1 1/2"
3/4"
1 1/2"
BUILDING CODE 2014 INDIANA BUILDING CODE
(REFERENCES IBC 2012 AND ASCE 7-10)
BUILDING IS NOT DESIGNED FOR VERTICAL EXPANSION
BUILDING IS NOT DESIGNED FOR HORIZONTAL EXPANSION
STRUCTURAL DESIGN LOADS:
SNOW LOADS:
SNOW EXPOSURE FACTOR, Ce
THERMAL FACTOR, Ct
SNOW IMPORTANCE FACTOR, Is
FLAT USE SNOW LOAD, Pf
WIND LOADS:
0.9
1.0
1.0
14 PSF,
(USE 20 PSF)
BASIC WIND SPEED
WIND EXPOSURE FACTOR
DIRECTIONALITY FACTOR, Kd
TOPOGRAPHY FACTOR, Kzt
SEISMIC DESIGN DATA:
SEISMIC IMPORTANCE FACTOR, Ie
115 MPH
C
0.85
1.0
SPECTRAL RESPONSE ACCELERATIONS
S1
SITE CLASSIFICATION (PER GEOTECH)
DESIGN SPECTRAL RESPONSE ACCELERATIONS
SDS
SD1
0.06
D
0.107
0.096
RISK CATEGORY II
GROUND SNOW LOAD, Pg 20 PSF
WIND IMPORTANCE FACTOR 1.0
Ss 0.10
ANALYSIS PROCEDURE
BASIC SEISMIC FORCE
RESISTING SYSTEM
N-S AND E-W DIRECTIONS
SEISMIC DESIGN CATEGORY B
EQUIVALENT LATERAL
FORCE PROCEDURE
RESPONSE MOFIFICATION COEFFICIENT, R
DEFLECTION AMPLIFICATION FACTOR
SEISMIC RESPONSE COEFFICIENT, Cs
DESIGN BASE SHEAR, V
6 1/2
4
0.011
XX kips
SYSTEM OVERSTRENGTH FACTOR 3
LIGHT FRAMED
WALLS SHEATHED
w/ WOOD PANELS
SEISMIC BRACING OF ARCHITECTURAL,
MECHANICAL, AND ELECTRICAL COMPONENTS:
ARCHITECTURAL COMPONENTS:
Ip = 1.5
MECH/ELECTRICAL COMPONENTS:
REQUIRED
Ip = 1.0 EXEMPT
Ip = 1.5
Ip = 1.0
EXEMPT
EXEMPT
VELOCITY PRESSURE EXP COEF, Kz or Kh 1.16
1.0
TYPICAL ROOF:
SUPERIMPOSED DEAD LOAD 15 PSF
TOTAL DEAD LOAD
LIVE LOAD (UNREDUCIBLE)20 PSF
P1
ANCHOR CAPACITY USED IN DESIGN IS BASED ON THE TECHNICAL DATA PUBLISHED BY
THE MANUFACTURER. SUBSTITUTION REQUESTS FOR ALTERNATE PRODUCTS MUST BE
APPROVED IN WRITING BY THE STRUCTURAL ENGINEER OF RECORD PRIOR TO USE.
PROVIDE CALCULATIONS DEMONSTRATING THAT THE SUBSTITUTED PRODUCT IS CAPABLE
OF ACHIEVING THE PERFORMANCE VALUES OF THE SPECIFIED PRODUCT. SUBSTITUTIONS
WILL BE EVALUATED BY THEIR HAVING AN ICC ESR SHOWING COMPLIANCE WITH THE
RELEVANT BUILDING CODE FOR SEISMIC USES, LOAD RESISTANCE, INSTALLATION
CATEGORY, AND AVAILABILITY OF COMPREHENSIVE INSTALLATION INSTRUCTIONS.
ADHESIVE ANCHOR EVALUATION WILL ALSO CONSIDER CREEP, IN-SERVICE TEMPERATURE
AND INSTALLATION TEMPERATURE.
P2
ANCHOR CAPACITY IS DEPENDENT UPON SPACING BETWEEN ADJACENT ANCHORS AND
PROXIMITY OF ANCHORS TO EDGE OF CONCRETE. INSTALL ANCHORS IN ACCORDANCE
WITH SPACING AND EDGE CLEARANCES INDICATED ON THE DRAWINGS.
P3
EXISTING REINFORCING BARS IN THE CONCRETE STRUCTURE MAY CONFLICT WITH
SPECIFIC ANCHOR LOCATIONS. REVIEW THE EXISTING STRUCTURAL DRAWINGS AND
SHOP DRAWINGS AND LOCATE THE POSITION OF THE REINFORCING BARS AT THE
LOCATIONS OF THE CONCRETE ANCHORS WITH SCANNING TECHNOLOGY. IF EXACT
LOCATION IS NOT DETERMINED, USE A DRILL BIT THAT WILL NOT CUT THE STEEL
REINFORCING. DO NOT CUT ANY REINFORCING WITHOUT SPECIFIC WRITTEN APPROVAL
OF THE STRUCTURAL ENGINEER.
P4
INSTALL ANCHORS PER THE MANUFACTURER INSTRUCTIONS. FOLLOW ALL
MANUFACTURER’S REQUIREMENTS FOR HOLE PREPARATION AND CLEANING.
P5
PER OSHA 29 CFR 1926.1153, DRILL AND CLEAN HOLES FOR POST INSTALLED ANCHORS
USING AN APPROVED DUSTLESS SYSTEM AND CAPTURE ALL DUST INTO A HEPA FILTERED
VACUUM. MANUFACTURER SPECIFIC SYSTEMS THAT MEET THE OSHA STANDARD ARE
ALSO PERMITTED.
P6
PROVIDE DOCUMENTATION THAT ALL OF THE CONTRACTOR’S PERSONNEL WHO INSTALL
ANCHORS ARE TRAINED PRIOR TO THE COMMENCEMENT OF INSTALLING ANCHORS. IF
CONTRACTOR DOES NOT HAVE PRIOR TRAINING, AN ANCHOR MANUFACTURER’S
REPRESENTATIVE IS TO PROVIDE ONSITE INSTALLATION TRAINING FOR ALL OF THEIR
ANCHORING PRODUCTS SPECIFIED.
P7
AN INSTALLER CERTIFIED THROUGH THE ACI/CRSI ADHESIVE ANCHOR INSTALLER
CERTIFICATION PROGRAM MUST INSTALL ADHESIVE ANCHORS SUPPORTING A SUSTAINED
TENSION LOAD IN A HORIZONTALLY OR UPWARDLY INCLINED ORIENTATION INTO
CONCRETE.
P8
PERFORM CONTINUOUS OR PERIODIC SPECIAL INSPECTION FOR POST INSTALLED
ANCHORS IN ACCORDANCE WITH THE ICC-ES REPORT FOR THE INDIVIDUAL ANCHOR.
NOTIFY SPECIAL INSPECTOR PRIOR TO COMMENCEMENT OF WORK TO COORDINATE
INSPECTION EFFORTS.
FOOTINGS
COMPRESSIVE STRENGTH
MAXIMUM WATER / CEMENT RATIO
AIR CONTENT
WATER REDUCING ADMIXTURE
SLUMP
4000 PSI
0.50
0 -3%
REQUIRED
4" -6"
FOUNDATION WALLS
COMPRESSIVE STRENGTH
MAXIMUM WATER / CEMENT RATIO
AIR CONTENT
WATER REDUCING ADMIXTURE
SLUMP
4500 PSI
0.50
0 -3%
REQUIRED
4" -6"
INTERIOR SLABS ON GRADE
COMPRESSIVE STRENGTH
AIR CONTENT
WATER REDUCING ADMIXTURE
SLUMP
COURSE AGGREGATE
3000 PSI
0 -3%
REQUIRED
4" -6"
GARAGE & EXTERIOR SLABS ON GRADE
COMPRESSIVE STRENGTH
AIR CONTENT
WATER REDUCING ADMIXTURE
SLUMP
COURSE AGGREGATE
3000 PSI
5 -7%
REQUIRED
4" -6"
CRUSHED STONE
DENSITY 150 LB / CU FT
DENSITY 150 LB / CU FT
DENSITY 150 LB / CU FT
DENSITY 150 LB / CU FT
MAXIMUM WATER / CEMENT RATIO 0.50
CRUSHED STONE
MAXIMUM WATER / CEMENT RATIO 0.40
F1
REFER TO DIVISION 31 SPECIFICATION SECTIONS FOR REQUIREMENTS IN ADDITION TO THOSE
LISTED BELOW.
F2
NOTE REQUIREMENTS ON PLANS AND IN SPECIFICATIONS FOR UNDERPINNING AND
PROTECTION OF EXISTING STRUCTURES. DO NOT UNDERMINE EXISTING CONSTRUCTION.
F3
BEAR FOOTINGS ON UNDISTURBED SOILS OR ENGINEERED FILL HAVING A MINIMUM NET
ALLOWABLE BEARING CAPACITY OF: 2000 POUNDS PER SQUARE FOOT
EXTEND EXTERIOR CONSTRUCTION DOWN A MINIMUM OF 3'-6" FEET BELOW EXTERIOR GRADE.
ELEVATIONS GIVEN ARE MINIMUM DEPTHS.
F5
THE SUBSURFACE CONDITIONS DESCRIBED IN THE GEOTECHNICAL REPORT REPRESENT
CONDITIONS ONLY AT THOSE SPECIFIC LOCATIONS AT THE PARTICULAR TIME THEY WERE
MADE. SUBSURFACE CONDITIONS DESCRIBED ON THE DRAWINGS SHOULD BE CONSIDERED
APPROXIMATE.
F6
REMOVE ORGANIC AND UNSUITABLE MATERIAL, AS DETERMINED BY THE OWNERS
GEOTECHNICAL CONSULTANT, PRIOR TO PLACING FILL AND REPLACE W/ ENGINEERED FILL.
PLACE FILL IN HORIZONTAL LAYERS WITHIN +/-2 PERCENT OF OPTIMUM MOISTURE CONTENT.
USE FILL LAYER THICKNESS APPROPRIATE FOR THE DEGREE OF FILL COHESIVENESS AND
COMPACTION ENERGY IMPARTED TO THE LIFT. COMPACT TO SPECIFIED DENSITY
REQUIREMENTS. IF ACCEPTABLE TO THE OWNER'S GEOTECHNICAL CONSULTANT, ON-SITE
MATERIALS THAT MEET PROJECT SPECIFICATIONS MAY BE USED FOR ENGINEERED FILL IF
MAINTAINED AT OPTIMUM MOISTURE CONTENT AND COMPACTED TO THE ABOVE CRITERIA.
SELECT BORROW MATERIALS WILL BE REQUIRED WHEN ON-SITE MATERIALS ARE UNSUITABLE
OR CANNOT BE COMPACTED TO THE CRITERIA STATED ABOVE.
F7
EXCAVATION TO SUITABLE BEARING SUBGRADES MAY PROCEED BY CONVENTIONAL
METHODS TO WITHIN 2.5 FEET OF THE PROPOSED FINAL SUBGRADES. PERFORM EXCAVATION
TO FINAL SUBGRADE USING A BACKHOE EQUIPPED WITH A SMOOTH BLADE TO MINIMIZE
DISTURBANCE OF THE BEARING SUBGRADE. FINISH FOOTING EXCAVATIONS BY HAND.
F8
DO NOT EXTEND THE GENERAL EXCAVATION ACROSS THE SITE DEEPER THAN 1'-0" BELOW
THE SLAB ON GROUND SUBGRADE ELEVATION. PERFORM THE EXCAVATIONS FOR PILE CAPS,
DRILLED PIER CAPS, GRADE BEAMS, SPREAD FOOTINGS, MATS, PITS, ETC ON AN INDIVIDUAL,
LOCALIZED BASIS DOWN FROM THE SLAB ON GROUND SUBGRADE ELEVATION.
F9
PROVIDE POSITIVE PROTECTION FOR EXCAVATION SLOPES AGAINST INSTABILITY AND
DETERIORATION DUE TO RAIN, WIND, SNOW OR ICE.
F10
RETAIN THE PERIMETER OF THE GENERAL EXCAVATION WITH A SOIL RETENTION SYSTEM AS
NECESSARY. THE DESIGN, INSTALLATION, MAINTENANCE AND REMOVAL OF THE SYSTEM IS
THE RESPONSIBILITY OF THE CONTRACTOR. PROVIDE APPROPRIATE MEASURES AND
PRECAUTIONS NECESSARY TO MINIMIZE SETTLEMENT OF EXISTING OR NEW CONSTRUCTION
INSIDE OR OUTSIDE OF THE PROJECT LIMITS. REPAIR DAMAGE TO NEW OR EXISTING
CONSTRUCTION INSIDE OR OUTSIDE PROJECT LIMITS CAUSED BY CONSTRUCTION
TECHNIQUES OR MOVEMENTS OF THE SOIL RETENTION SYSTEM.
F11
THE EXPOSED SUBGRADE SOILS MAY BE SENSITIVE TO DISTURBANCE AND STRENGTH
DEGRADATION WHEN HIGH MOISTURE CONTENTS ARE PRESENT. MINIMIZE CONSTRUCTION
TRAFFIC OVER EXPOSED SUBGRADES. DO NOT POND WATER ON THE SUBGRADES. CONTROL
SURFACE AND GROUND WATER BY PROPER SITE GRADING, PERIMETER CUTOFF TRENCHES,
AND SUMP AND PUMP METHODS OF DEWATERING. CONSTRUCT CUTOFF TRENCHES AND
SUMPS OUTSIDE THE INFLUENCE OF PROPOSED FOUNDATIONS.
F12
THE OWNER'S GEOTECHNICAL CONSULTANT MUST REVIEW AND APPROVE FINISHED
EXCAVATIONS AND BEARING SUBGRADES BEFORE PLACING CONCRETE. PROVIDE ADDITIONAL
EXCAVATION AS NECESSARY TO ACHIEVE THE REQUIRED BEARING CAPACITY.
F13
USE SIDE FORMS FOR FOOTINGS AND GRADE BEAMS. CLEAN REINFORCEMENT IMMEDIATELY
PRIOR TO PLACING CONCRETE.
F14
DO NOT PLACE CONCRETE IN AN EXCAVATION CONTAINING FREE WATER, FROST, ICE OR
FROZEN GROUND. PROVIDE NECESSARY MEASURES TO PREVENT FROST OR ICE FROM
PENETRATING FOOTING OR SLAB SUBGRADE, BOTH BEFORE AND AFTER CONCRETE
PLACEMENT AND UNTIL SUBGRADES ARE FULLY PROTECTED BY THE PERMANENT BUILDING
STRUCTURE.
F15
PLACE THE CONCRETE FOR EACH FOOTING IN ONE CONTINUOUS POUR. LIMIT BASEMENT
WALL POUR LENGTHS TO 65 FEET.
F16
PLACE BACKFILL AGAINST FOUNDATION WALLS TO MAINTAIN A FILL LEVEL WITHIN 1'-0" OR
LESS ON OPPOSITE SIDES OF THE WALL. BRACE FOUNDATION WALLS AND GRADE BEAMS
DURING THE OPERATION OF BACKFILLING AND COMPACTION. LEAVE BRACING IN POSITION
UNTIL PERMANENT RESTRAINTS BECOME EFFECTIVE.
M1
EMPLOY A LICENSED SURVEYOR TO VERIFY EXISTING DIMENSIONS, FLOOR ELEVATIONS, AND
FLOOR-TO-FLOOR HEIGHTS BEFORE ORDERING, DETAILING, FABRICATING, OR ERECTING
STRUCTURAL STEEL. THIS INFORMATION MUST BE CONFIRMED AT LOCATIONS WHERE NEW
FLOORS AND ROOFS MEET EXISTING CONSTRUCTION.
M2
CONSULT THE ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR
LOCATION AND SIZE OF CHASES, INSERTS, OPENINGS, SLEEVES, WASHES, DRIPS, REVEALS,
DEPRESSIONS, EQUIPMENT PADS AND OTHER PROJECT REQUIREMENTS. COMBINE THE
REQUIREMENTS INTO THE SHOP DRAWINGS AND THE WORK. PROVIDE STRUCTURAL FRAMING
PER TYPICAL DETAILS AS REQUIRED AT FLOOR AND ROOF OPENINGS WHERE STRUCTURAL
FRAMING IS NOT SHOWN.
M3
THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION OF
CONSTRUCTION OF THE PROJECT AND THEN, ONLY TO SUPPORT THE DESIGN LOADS
INDICATED. THE CONTRACTOR IS RESPONSIBLE FOR MEANS, METHODS AND SEQUENCE OF
CONSTRUCTION AND FOR THE ADEQUACY OF THE STRUCTURE TO SUPPORT LOADS
OCCURRING DURING CONSTRUCTION. FURNISH TEMPORARY BRACING, SHORING, AND/OR
SUPPORT AS REQUIRED.
M4
CHECK DIMENSIONS AGAINST THE REQUIREMENTS OF OTHER CONTRACT DOCUMENTS.
RESOLVE APPARENT INCONSISTENCIES IN THE CONTRACT DOCUMENTS WITH THE
ARCHITECT/ENGINEER BEFORE PROCEEDING WITH WORK.
M5
SHOW OPENINGS THROUGH STRUCTURAL MEMBERS ON THE SHOP DRAWINGS SUBMITTED
FOR REVIEW. OPENINGS WHICH ARE NOT SHOWN ON THE STRUCTURAL DRAWINGS ARE
SUBJECT TO REVIEW AND ACCEPTANCE AND ARE TO BE CLEARLY INDICATED FOR REVIEW
AND ACCEPTANCE ON THE SHOP DRAWINGS.
M6
DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE
CONDITIONS ARE NOT SPECIFICALLY SHOWN, USE DETAILS OF SIMILAR CONSTRUCTION,
SUBJECT TO APPROVAL BY THE ENGINEER.
M7
WHEREVER THERE IS CONFLICT BETWEEN DETAILS OR TWO DETAILS APPLYING TO THE SAME
CONDITION, THE ENGINEER WILL HAVE SOLE AUTHORITY TO DETERMINE WHICH DETAIL IS THE
MOST APPROPRIATE FOR THE CONDITION.
M9
PROMPTLY NOTIFY THE ENGINEER OF ANY STRUCTURAL MEMBER CALLED OUT ON THE
ARCHITECTURAL, MECHANICAL, PLUMBING OR ELECTRICAL DRAWINGS THAT IS NOT
IDENTIFIED ON THE STRUCTURAL DRAWINGS. DESIGN OF THESE MEMBERS WILL BE
PROVIDED AS NECESSARY BY THE STRUCTURAL ENGINEER UPON NOTIFICATION.
M10
THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE LOCATION AND
PLACEMENT OF INSERTS, HANGERS AND OTHER MISCELLANEOUS ITEMS REQUIRED FOR THE
SUPPORT OF MECHANICAL, ELECTRICAL AND PLUMBING ITEMS SUSPENDED FROM THE
STRUCTURE.
M11
DO NOT MAKE MODIFICATIONS, ALTERATIONS OR REPAIRS TO THE STRUCTURE WITHOUT
PRIOR REVIEW BY THE STRUCTURAL ENGINEER. SUBMIT DETAILS AND CALCULATIONS
PREPARED BY A PROFESSIONAL ENGINEER REGISTERED IN STATE WHERE PROJECT IS
LOCATED AND EMPLOYED BY CONTRACTOR.
C1
REFER TO DIVISION 03 SPECIFICATIONS FOR REQUIREMENTS IN ADDITION TO THOSE LISTED
BELOW.
C2
A QUALITY CONTROL PROGRAM OF FIELD TESTING AND INSPECTION WILL BE PERFORMED ON
STRUCTURAL CONCRETE WORK IN ACCORDANCE WITH THE SPECIFICATIONS. SCHEDULE
WORK AND PROVIDE ACCESS TO ALLOW THE TESTING REQUIREMENTS TO BE COMPLETED.
PROVIDE ADEQUATE NOTICE TO ALLOW THE OWNER'S TESTING AGENCY TO REVIEW
PLACEMENT OF REINFORCEMENT PRIOR TO PLACING CONCRETE.
C3
SUBMIT ENGINEERED CONCRETE MIX DESIGNS, INCLUDING REQUIRED BACKUP DATA, FOR
EACH TYPE OF CONCRETE PROPOSED FOR USE TO THE ARCHITECT/ ENGINEER FOR REVIEW.
ALLOW ADEQUATE TIME FOR REVIEW PRIOR TO PERFORMING CONCRETE WORK.
C4
DETAIL, FABRICATE, LABEL, SUPPORT AND PLACE CONCRETE REINFORCEMENT IN
ACCORDANCE WITH ACI 315 "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT" AND
ACI 318 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE", LATEST EDITIONS.
C5
SUBMIT DETAILED SHOP DRAWINGS INDICATING REINFORCEMENT SIZE, SPACING AND
PLACEMENT TO THE ARCHITECT/ENGINEER FOR REVIEW PRIOR TO FABRICATION. INCLUDE
DETAILS AND LOCATIONS OF CURBS, CONSTRUCTION JOINTS, SLAB DEPRESSIONS, SLEEVES,
OPENINGS, ETC.
C6
SAWCUT SLABS ON GROUND IN THE PATTERN SHOWN ON PLAN. START SAWCUTTING AS
SOON AS THE SAW WILL NOT RAVEL EDGES OR DISLODGE AGGREGATE, BUT IN NO CASE
MORE THAN 12 HOURS AFTER THE SLAB IS PLACED.
C7
COORDINATE LOCATION OF CONSTRUCTION JOINTS WITH ENGINEER PRIOR TO
COMMENCEMENT OF CONCRETE WORK.
C8
CLEAN AND MOISTEN CONSTRUCTION JOINTS IMMEDIATELY PRIOR TO PLACING FRESH
CONCRETE.
C9
COORDINATE THE LOCATION OF INSERTS, EMBEDDED PLATES, ANCHORS, REGLETS AND
SIMILAR ITEMS REQUIRED BY OTHER TRADES TO BE PLACED IN CONCRETE. MAINTAIN
CORRECT LOCATION OF REINFORCING BARS WHEN PLACING THESE ITEMS.
C10
UNLESS NOTED OTHERWISE, PROVIDE DOWELS TO MATCH MAIN REINFORCEMENT SIZE AND
SPACING. PROVIDE TENSION LAP SPLICE UNLESS NOTED OTHERWISE.
C11
DO NOT USE CALCIUM CHLORIDE IN CONCRETE.
C12
REFER TO THE ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR
CURBS, PADS, DEPRESSIONS, WALL/SLAB OPENINGS, SPECIAL FLOOR FINISHES, ETC.
C14
PROVIDE AIR-ENTRAINING IN CONCRETE AS SET FORTH IN THE SPECIFICATIONS.
C15
PROVIDE ONLY THOSE OPENINGS INDICATED ON THE REVIEWED SHOP DRAWINGS.
C16
REFER TO ACI 305 FOR REQUIREMENTS FOR PLACING CONCRETE IN HOT WEATHER AND TO
ACI 306 FOR REQUIREMENTS FOR PLACING CONCRETE IN COLD WEATHER.
C18
WHERE FIBER REINFORCEMENT IS SPECIFIED, A REPRESENTATIVE FROM THE FIBER
MANUFACTURER SHALL ADVISE ON SPECIAL PLACING AND FINISHING TECHNIQUES.
C19
PROVIDE ONLY CONCRETE AND REINFORCING MATERIALS OF THE TYPES AND GRADES
LISTED IN THE TABLE BELOW, UNLESS NOTED OTHERWISE.ARCHITECTCONSTRUCTION MANAGERPROJECTDRAWING TITLESEALSHEETPROJECT INFOREVISIONSBID DOCUMENTS
10-26-22
21011 CLIENTS001GENERAL NOTES ANDABBREVIATIONSCARMELTOWNSHIP BLDG.RENOVATION ANDEXPANSIONABBREVIATIONS STRUCTURAL DESIGN LOADS
POST INSTALLED ANCHORS AND REBAR
FOUNDATION NOTES MISCELLANEOUS
STRUCTURAL CONCRETE NOTES
STRUCTURAL CONCRETE NOTES (CONT)
03/10/23